Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

64 results (0,14471 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Soteria Dimension Mounting Box FL5000-200APO

Apollo Detector Ceiling Tile Mounting Box - 45681-309APO

Apollo Deckhead Mounting Box 45681-217APO

Apollo Deckhead Mounting Box 45681-217APO

Apollo Deckhead Mounting Box 45681-217APOMechanical ConstructionThe Deckhead Mounting Box is used on its own in most cases but there are applications where either an extension sleeve or an adaptor ring is required. The Extension Sleeve is required when fitting heater or deep bases the Adaptor Ring is needed for fitting sounder bases beacon bases or sound beacon bases. Further details are given in the table below. The Extension Sleeve and the Adaptor Ring are sold as an Accessory Kit part no 45681-218.The Deckhead Mounting Box has 6 cable access ports for M20 glands and is secured to the mounting surface via two 5.4mm holes in the webs.Additional InformationFor more information refer to Installation Guide 39214-450 and Datasheets PP2364 PP2040.Safety NoteNOTES ON USE 1. Do not apply any sealing compound or use a gasket of any kind between the detector base and deckhead mounting box 2. Ensure that if a terminal block is fitted it does not contact or foul the detector base 3. Ensure that the mounting surface is flat and Level 4. Seal unused cable access ports with suitable blanking plugs. Sealing compound may be used provided that it does not at any time give off fumes or vapour which could affect any detector fitted to the base 5. The deckhead mounting box orientation should be such that the detector LED is facing the entrance to the protected areaProduct InformationThe Deckhead Mounting Box part no 45681-217 is a device which protects bases sounder bases and sounder beacon bases from the ingress of water or other liquids. It is screwed to the soffit and accepts a variety of Apollo bases.Key FeaturesProtects against water ingressImproved performanceAvailable in polycarbonate or metalPolycarbonate deckhead mounting box 45681-217 also fits Apollo audio visual bases when used with the accessory kit 45681-218Additional Information 3Weight of DeckheadMounting Box Backbox 100gExtension sleeve 23gAdaptor Ring 29g

GBP 12.54
1

Apollo Sounder Ceiling Tile Mounting Box - 45681-310APO

Apollo Deckhead Mounting Box Accessory Kit 45681-218APO

Apollo 29600-800 Sonos Pulse Wall VAD Deep Base Red BodyWhite Flash W-3.1-11.3

Apollo 29600-801 Sonos Pulse Wall VAD Deep Base Red BodyRed Flash W-2.4-7.5

Apollo 29600-804 Sonos Pulse Wall Sounder VAD Shallow Base Red BodyWhite Flash W-3.1-11.3

Apollo 29600-807 Sonos Pulse Wall Sounder VAD Deep Base Red BodyRed Flash W-2.4-7.5

Apollo 29600-805 Sonos Pulse Wall Sounder VAD Shallow Base Red BodyRed Flash W-2.4-7.5

Apollo 29600-806 Sonos Pulse Wall Sounder VAD Deep Base Red BodyWhite Flash W-3.1-11.3

Apollo Wall Loop Powered VAD White Body White Flash 55000-744APO

Apollo MiniDisc Remote Indicator 53832-070APO

Apollo Wall Loop Powered VAD Red Body White Flash 55000-741APO

Apollo SA4700-100APO Intelligent Switch Monitor

Apollo SA4700-102APO Intelligent Input Output Unit

Apollo SA6700-100APO Intelligent Twin Switch Monitor

Apollo Discovery Optical Smoke Detector 58000-600APO

Apollo Discovery Optical Smoke Detector 58000-600APO

Apollo Discovery Optical Smoke Detector 58000-600APOThe Discovery Optical Smoke Detector operates using the light scatter principle and is ideal for applications where slow-burning or smouldering fires pose a potential risk. Discovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms. Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber.OperationThe Discovery Optical Detector has a white moulded polycarbonate case with wind-resistant smoke inlets. The two indicator LEDs are red in alarm. Within the case is a printed circuit board which on one side has the light-proof chamber with integral gauze surrounding the optical measuring system and on the other the signal processing and communications electronics. An infra-red light emitting diode within its collimator is arranged at an obtuse angle to the photo-diode. The photo-diode has an integral daylight-blocking filter.The IR LED emits a burst of collimated light every second. In clear air the photo-diode receives no light directly from the IR LED because of the angular arrangement and the chamber baffles. When smoke enters the chamber it scatters light from the emitter IR LED onto the photo-diode in an amount related to the smoke characteristics and density. The photo-diode signal is processed to provide an analogue value for transmission when the detector is interrogated.Key FeaturesResponds well to slowburning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFive response modesRemote test feature

GBP 40.98
1

Apollo Discovery Marine Optical Smoke Detector 58000-600MAR

Apollo Discovery Marine Optical Smoke Detector 58000-600MAR

Apollo Discovery Marine Optical Smoke Detector 58000-600MARThe Discovery Marine Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.Operating PrinciplesThe Discovery Marine Optical Smoke Detector has a white moulded polycarbonate case with wind-resistant smoke inlets.The indicator LEDs are colourless when the detector is in quiescent state and red in alarm. Within the case is a printed circuit board which on one side has the light-proof chamber with integral gauze surrounding the optical measuring system and on the other the signal processing and communications electronics.An infra-red light emitting diode within its collimator is arranged at an obtuse angle to the photo-diode. The photo-diode has an integral daylight-blocking filter.The IR LED emits a burst of collimated light every second.In clear air the photo-diode receives no light directly from the IR LED because of the angular arrangement and the chamber baffles. When smoke enters the chamber it scatters light from the emitter IR LED onto the photo-diode in an amount related to the smoke characteristics and density. The photo-diode signal is processed to provide an analogue value for transmission when the detector is interrogated.Maintenance ServiceDetectors should be maintained according to BS 5839-1 or other locally applicable code. Test Equipment can be ordered from us which can test smoke and heat detectors. Detectors should not be cleaned in the field except for careful removal of exterior dirt with a damp cloth.Key FeaturesResponds well to slow-burning smouldering firesSuitable for bedrooms and escape routesUnaffected by wind or atmospheric pressureRemote test featureRejection of transient signals

GBP 59.16
1

Apollo Orbis Heater Detector Base - ORB-HB-00020-APO

Apollo RW1500-110APO Reach Open-Area Sounder White Body

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1