Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

3 results (0,12947 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Soteria Heat Detector Isolated SA5100-400

Apollo Soteria Heat Detector Isolated SA5100-400

Apollo Soteria Heat Detector Isolated SA5100-400TheSOTERIA Heat Detector features two heat sensors located laterally to ensure good heat detection in all orientations.Backwards CompatibilitySoteria detectors have been designed to operate on XP95 and Discovery loops. This allows for Soteria detectors and bases to operate on existing systems and for Soteria detectors to operate on XP95 and Discovery bases XPERT 7 Intelligent Mounting Base. It should be noted that not all features of Soteria will be available when used with XP95 or Discovery fire control panels.If Soteria detectors are used with XP95 fire control panels incorporating drift compensation algorithms these must be disabled when communicating with Soteria devices. When Soteria detectors are used with an XPERT 7 Intelligent Mounting Base on a CoreProtocol system Soteria devices will have a 128 address offset due to only 7 address pips being available on the XPERT 7 card. For example an XPERT 7 card set at 32 will address as 160 on CoreProtocol with Soteria detectors.Key FeaturesDual heat sensorsUtilises digital CoreProtocol communicationsCompatible with XP95 and Discovery systemsCompatible with existing fire control panelsMechanically compatible with existing basesAvailable with or without integrated switchable isolatorTri-coloured LED status indicatorPolycarbonate moulding for colour stability and strengthComprehensively tested to exceed EN 54-5 standardFasTest for quicker testing of detectorsXPERT card addressing or auto addressingLocking mechanism grub screwPlease Note Not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.

GBP 41.20
1

Apollo Soteria Optical Smoke Detector Isolated SA5100-600

Apollo Soteria Optical Smoke Detector Isolated SA5100-600

Apollo Soteria Optical Smoke Detector Isolated SA5100-600TheSOTERIA Optical Detector uses new optical sensing technology PureLight to detect smoke particles entering the chamber. PureLight marks a new stage in the development of Apollo optical technology and aims to reduce the possibility of false alarms and to increase the reliability of detection of a real fire.Backwards CompatibilitySoteria detectors have been designed to operate on XP95 and Discovery loops. This allows for Soteria detectors and bases to operate on existing systems and for Soteria detectors to operate on XP95 and Discovery bases XPERT 7 Intelligent Mounting Base. It should be noted that not all features of Soteria will be available when used with XP95 or Discovery fire control panels.If Soteria detectors are used with XP95 fire control panels incorporating drift compensation algorithms these must be disabled when communicating with Soteria devices. When Soteria detectors are used with an XPERT 7 Intelligent Mounting Base on a CoreProtocol system Soteria devices will have a 128 address offset due to only 7 address pips being available on the XPERT 7 card. For example an XPERT 7 card set at 32 will address as 160 on CoreProtocol with Soteria detectors.Key FeaturesPureLight optical technology reduces false alarms and enhances smoke recognitionUtilises digital CoreProtocol communicationsCompatible with XP95 and Discovery systemsCompatible with existing fire control panelsMechanically compatible with existing basesAvailable with or without integrated switchable isolatorDrift compensationTri-coloured LED status indicatorPolycarbonate moulding for colour stability and strengthComprehensively tested to exceed EN 54-7 standardFasTest for quicker testing of detectorsXPERT card addressing or auto addressingLocking mechanism grub screwPlease Note not all features are available when SOTERIAdevices are connected to an XP95 or Discovery fire control panel.

GBP 41.20
1

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1