Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised OutputThe module is a single input and single supervised output mini module. The module contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFI-IO-SM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to remotely monitor a single circuit and control a single ancillary circuit using external power. Both input and output circuits are monitored for fault conditions. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeProvides both a fully monitored input and output circuitFast fit plug-in cable connectionsAlternate mechanical variants available to satisfy different applicationsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay OutputSingle input and single relay output mini module. VMMIC120 contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFIIO- RM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to both remotely monitor a single circuit and control a single ancillary circuit using a set of volt-free changeover relay contacts. The input circuit is monitored for fault condition. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeCan both monitor an input circuit and switch dual volt-free changeover relay contactsFast fit plug-in cable connectionsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HFW-IM-03 Wireless Single Channel Input Module

Hyfire HF-CP1-52 Single Loop Panel

Hyfire HFI-OM-RM-01 Mini Mount Single Relay Output Module

Hyfire HFI-IM-SM-01 Mini Mount Single Supervised Input Module

Hyfire HFI-OM-SM-01 Mini Mount Single Supervised Output Module

Hyfire HFW-BOM-03 Wireless Single Channel Powered Output Module

Hyfire HF-CP1-LD-52 Single Loop Panel - Deep Enclosure

Hyfire HF-CP1-LD-52 Single Loop Panel - Deep Enclosure

Hyfire HF-CP1-LD-52 Single Loop Panel - Deep EnclosureSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 1467.20
1

Hyfire HFI-ABSB-23R-06 Intelligent Plus Loop Powered Base SounderVAD EN54 Red lens - Altair

Hyfire HFI-ABSB-23W-06 Intelligent Plus Loop Powered Base SounderVAD EN54 White Lens Altair

Hyfire HFI-ABS-06 Intelligent Plus Loop Powered Sounder Base Altair

Hyfire TAU-MI-S-01 Taurus Input Module

Hyfire Platform Sounder Beacon Base HFI-ABSB-05

Hyfire Intelligent Loop Powered Sounder Base HFI-ABS-05

Hyfire HFI-CZM-01 Conventional Zone Interface Module

Hyfire HFI-CZM-01 Conventional Zone Interface Module

Hyfire HFI-CZM-01 Conventional Zone Interface ModuleThe VMCZ conventional zone module allows the connection of conventional detectors to a Vega intelligent loop. The module has an onboard relay output driven by the fire alarm control panel. The VCMZ module is designed to provide different current limits.The HFI-CZM-01 conventional zone module is a device permitting to interface an analogue-intelligent addressable loop to a conventional detection zone. The analogue panel sees this device and all the conventional sub-system as a single addressed device on the loop. Conventional zone conditions as normal open and short circuit and alarm are detected by this module and notified to the analogue control panel by the module itself nevertheless this device is not capable of detecting the removal of a sensor from the conventional line. The conventional zone module can be powered in different ways either directly by the analogue detection loop or by an external power supply source. The conventional zone module is capable of monitoring its power supply whether from the analogue loop or external and measure the actual current that is flowing to the conventional zone line giving the analogue control panel full control over the conventional sub-system and its status.Key FeaturesCan be powered either externally or from the loopShort circuit isolator built inAuto addressing capabilityAddressable via HFI-DPT-05 programmer5 year product warrantyAdjustable reset time allowing for greater loop lengthEnd of line options to allow for multiple application from one device

GBP 87.01
1

Hyfire HFW-TRI-05 Intelligent Wireless Tri-Sensor Detector cw Base and Batteries Libra

Hyfire HFW-TRI-05 Intelligent Wireless Tri-Sensor Detector cw Base and Batteries Libra

Hyfire HFW-TRI-05 Intelligent Wireless Tri-Sensor Detector cw Base and Batteries LibraThe HFW-TRI-05 Tri-Sensor detector CO smoke heat is the latest in wireless multi-criteria detection technology. It is a fully intelligent device and compatible with the Static wireless translator and expander modules.The detector combines CO sensing dual-path smoke and heat detection technologies for unrivalled performance maintaining high levels of unwanted alarm rejection. The device complies with EN54-31 point detectors using a combination of smoke carbon monoxide and optionally heat sensors which considers tow possible MT and NT operative modes. The MT mode requires at least two independent stimuli eg smoke CO thermal smoke to get to a full alarm whilst the NT operative mode allows a full alarm to be generated from a single stimulusOur device offers various possible environmental profiles for each of the two modes further improving nuisance rejection and guaranteeing the promptest fire detection.Key FeaturesDual angle scattering analysis optical chamber designSolid electrolite carbon monoxide sensor 10 years lifeInternal algorithm processing optimises performance12 profiles available from harshindustrial to ultraclean environmentsUtilises standard low cost lithium battery technology8 year battery lifeDevice identification tabFast magnet test feature for engineer testingTwin alarm LEDs for 360 visibilityApproved to EN54-5 EN54-7 EN54-31 and EN54-25

GBP 304.14
1

Hyfire HF-CP4-1-52 1-4 Loop Panel cw 1 Loop Card

GBP 2012.21
1

Hyfire HF-CP2-2-52 1-2 Loop Panel cw 2 Loop Cards

Hyfire HF-CP2-2-52 1-2 Loop Panel cw 2 Loop Cards

Hyfire HF-CP2-2-52 1-2 Loop Panel cw 2 Loop CardsSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 1631.53
1