Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

320 results (0,14559 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec K375 Relay Board Single Way

Kentec Sigma XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1 K11031M2

Kentec Sigma XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1 K11031M2

Kentec SigmaK11031M2XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1Designed and manufactured to the highest standards in a quality controlled environment and with European EN12094-1 approvals the Sigma XT K11031M2 extinguishant releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations. With three detection zones as standard extinguishant release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three type activations such as would be required for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma XT K11031M2 allow the functionality of the system to be extensively modified while still complying with the requirements of the controlling standard for the equipment EN12094-1 EN54-2 and EN54-4. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until extinguishant release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the extinguishant system status. With all of the electronics mounted on a single easily removable steel plate Sigma XT panels are both robust and easy to install. Sigma XT is supplied in an enclosure that matches the design and colour of the Sigma CP range.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-4Three detection zones as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage sounder delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable extinguishant delays up to 60 seconds in 5 second stepsConfigurable extinguishant duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until releaseSupports up to seven four wire status indicatorsBuilt in Extract Fan control

GBP 587.21
1

Kentec INST-SFP-SS-20K-1 SFP Single Mode Fibre Optic Transceiver 20Km

Kentec INST-SFP-SS-20K-1 SFP Single Mode Fibre Optic Transceiver 20Km

Kentec INST-SFP-SS-20K-1 SFP Single Mode Fibre Optic Transceiver 20KmINST-SFP-SS-20K-1 is a fibre optic transceiver for use with single mode fibre optic cable and operates at a nominal wavelength of 1310nm. This dongle is locked and pre-configured for use with the DNX-R-2FFC-K RS485Fibre Dual Fibre Dynamic Network Analyser.INST-SFP-SS-20K-1 transceivers are hot-pluggable making it quick easy to replace and also swap between alternate fibre optic modes. Maximum range is 20Km based upon a 9125m fibre optic cable.The transmitter section uses a multiple quantum well 1310nm laser and is class 1 laser compliant according to International Safety Standard IEC60825.The receiver section uses an Integrated GaAs detector pre-amplifier IDP mounted in an optical header and a limiting post-amplifier IC. INST-SFP-SS-20K-1 is designed to be compliant with SFF-8472 MSA. Built in digital diagnostic functions allow monitoring of the transceiver by the DNX-R-2FFC-K analyser module and subsequently the IVIEW software tool. This allows performance monitoring along with early warning of a potential issue to enable preventative maintenance.Key FeaturesPlug-in transceiver for use with DNX-R-2FFC-K analysers provides a single mode fibre communication link between transceivers on the networkMax distance between analysers 20kmOperating data rates up to 1.25Gbps1310nm FP laser transmitter20km reach for 9125m fibre optic cableSingle 3.3V power supply and TTL Logic InterfaceHot-pluggable SFP footprint duplex LC connector interfaceClass 1 FDA and IEC60825-1 laser safety compliantCommercial temperature range 070CCompliant with SFF-8472 MSABuilt-in digital diagnostic functions including optical power monitoring

GBP 131.75
1

Kentec Syncro AS Lite Single Loop Surface Control Panel LA80161M2 - Apollo Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LH81161M2 - Hochiki Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LA81161M2 - Apollo Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LH80161M2 - Hochiki Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LV80161M2 - Argus Vega Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LV81161M2 - Argus Vega Protocol

Kentec INST-SFP-BiDi-10K-AB-1 SFP Bi-directional Single Mode Fibre Optic Transceiver 1550nm TX1310

Kentec INST-SFP-BiDi-10K-AB-1 SFP Bi-directional Single Mode Fibre Optic Transceiver 1550nm TX1310

Kentec INST-SFP-BiDi-10K-AB-1 SFP Bi-directional Single Mode Fibre Optic Transceiver 1550nm TX1310INST-SFP-BiBi-10K-AB-1INST-SFP-BiBi-10K-BA-1 are fibre optic transceivers for use with multi mode fibre optic cable and operate at a nominal wavelength of 850nm.This dongle is locked and preconfigured for use with Kentec DNP-R-2FFC-K Passive Dual Port Optic FibreRS485 Medium Converter.Transceivers are hot-pluggable making them quick easy to replace and also swap between alternate fibre optic modes. Maximum range will be dependent upon the fibre optic cable used 62.5125m range of 550m 50125m can extend the range up to 1km.The transmitter section uses a Vertical Cavity Surface Emitted Laser and is Class 1 laser compliant according to International Safety Standard IEC60825.The receiver section uses an Integrated Gas detector pre-amplifier IDP mounted in an optical header and a limiting post-amplifier IC. AB-1BA-1 are designed to be compliant with SFF-8472 MSA.Built in digital diagnostic functions allow monitoring of the transceiver by the DNP-R-2FFC-K converter module and subsequently the IVIEW software tool. This allows performance monitoring along with early warning of a potential issue to enable preventative maintenance.Key FeaturesOperating data rates up to 1.25Gbps10km reach for 9125m Single Mode FibreSingle 3.3V power supply and TTL Logic InterfaceLow power dissipationHot-pluggable SFP footprintBIDI LCUPC type pluggable optical interfaceClass 1 FDA and IEC60825-1 laser safety compliantBuilt in digital diagnostic functions including optical power monitoringRoHS compliant and lead-freeCompliant with SFP MSACompliant with SFF-8472Compliant with IEEE 802.3z

GBP 149.22
1

Kentec INST-SFP-BiDi-10K-BA-1 SFP Bi-directional Single Mode Fibre Optic Transceiver 1310nm TX1550

Kentec INST-SFP-BiDi-10K-BA-1 SFP Bi-directional Single Mode Fibre Optic Transceiver 1310nm TX1550

Kentec INST-SFP-BiDi-10K-BA-1 SFP Bi-directional Single Mode Fibre Optic Transceiver 1310nm TX1550INST-SFP-BiBi-10K-AB-1INST-SFP-BiBi-10K-BA-1 are fibre optic transceivers for use with multi mode fibre optic cable and operate at a nominal wavelength of 850nm.This dongle is locked and preconfigured for use with Kentec DNP-R-2FFC-K Passive Dual Port Optic FibreRS485 Medium Converter.Transceivers are hot-pluggable making them quick easy to replace and also swap between alternate fibre optic modes. Maximum range will be dependent upon the fibre optic cable used 62.5125m range of 550m 50125m can extend the range up to 1km.The transmitter section uses a Vertical Cavity Surface Emitted Laser and is Class 1 laser compliant according to International Safety Standard IEC60825.The receiver section uses an Integrated Gas detector pre-amplifier IDP mounted in an optical header and a limiting post-amplifier IC. AB-1BA-1 are designed to be compliant with SFF-8472 MSA.Built in digital diagnostic functions allow monitoring of the transceiver by the DNP-R-2FFC-K converter module and subsequently the IVIEW software tool. This allows performance monitoring along with early warning of a potential issue to enable preventative maintenance.Key FeaturesOperating data rates up to 1.25Gbps10km reach for 9125m Single Mode FibreSingle 3.3V power supply and TTL Logic InterfaceLow power dissipationHot-pluggable SFP footprintBIDI LCUPC type pluggable optical interfaceClass 1 FDA and IEC60825-1 laser safety compliantBuilt in digital diagnostic functions including optical power monitoringRoHS compliant and lead-freeCompliant with SFP MSACompliant with SFF-8472Compliant with IEEE 802.3z

GBP 149.22
1

Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control Panel

Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control Panel

Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boardsExtinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC input

GBP 804.47
1

Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control Panel

Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control Panel

Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1174.42
1

Kentec DNP-R-2FFC-K Passive RS485Fibre amp Dual Fibre Dynamic Network Analyser

Kentec DNP-R-2FFC-K Passive RS485Fibre amp Dual Fibre Dynamic Network Analyser

Kentec DNP-R-2FFC-K Passive RS485Fibre Dual Fibre Dynamic Network AnalyserThe DNP-R-2FFC-K is a full fibre or hybrid copperfibre modem developed for use with fire panels in the life safety industry. The equipment is designed to improve the Quality of Service QoS of critical communication networks while operating under the performance criteria required by EN54-13 and BS5839 part 1.DNP-R-2FFC-K is designed to support dual fibre connectivity Fibre in Fibre out using the range of INS Small Form-factor Pluggable fibre optic transceivers. INS transceivers are available to support single-mode multimode and Bi-Directional fibre optic cables with distances of up to 160km.DNP-R-2FFC-K is also designed to support fibre optic to RS485 copper wiring which allows sections of an RS485 network to be converted to fibre optic cables either for enhanced transmission distances or to overcome problems with EMI Electro-Magnetic Interference.Configuring the module for fibre or RS485 fibre configurations is done through a single switch option. Simple LED indications provide detailed information regarding the communication status of each port signal quality transceiver status etc.Key FeaturesSupport Full Fibre or RS485Fibre configurationsOnly one module required per panelSimple LED status indications provide detailed diagnostic infoSupports INS Small Form-factor Pluggable SFP Fibre Optic transceiversRedundant power supply connections for increased reliabilityBaud rate selectable 9600 - 115200 bitssecDIN rail mountingSupport of single and dual port industrial equipment

GBP 1399.07
1

Kentec K1823-40 Elite Extinguishant Abort Switch Unit Grey Surface

Kentec K1823-10 Elite Extinguishant Abort Switch Unit Red Surface

Kentec K24200-M10 Yellow Indicator Audio Visual Unit - Plant Isolated Indicator Only