34 results (0,15050 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley KA-1 Steam Trap

Vesda Xtralis KA-1 Steam Trap

Patol DTB25 PVC Dirt Trap Box 6900285P

Patol DTB25 PVC Dirt Trap Box 6900285P

Patol DTB25 PVC Dirt Trap Box 6900285PThe PVC Dirt Trap Box is used as an accessory part for an Aspirating Smoke Detector in areas with high dust content to prevent false alarms and to increase the lifespan of the smoke sensors substantially.When using the dust trap we generally recommend the combination with the large or extra-large filter-box.Due to the Dirt Trap Box design dust particles are deposited on the bottom due to gravity. Smoke particles pass through the Dirt Trap Box unhindered to the small size of the particles. Reliable and fast fire detection is thus ensured.The air polluted with dust particles is also aspirated by the aspirating smoke detector. So that these particles do not cause any false alarms the aspirated air must be purified of these particles.The Dirt Trap Box can be used for this purpose as an additional accessory component. This is then to be arranged in front of the filter-box in the suction pipe see project planning notice.The aspirated air reaches the Dirt Trap Box via the entry opening underneath. En-route to the exit opening above the air is separated from most of the dust particles which are deposited on the bottom of the chamber due to gravity. The gathered dust can be removed during maintenance work simply by opening the lid.Key FeaturesPrevention or substantial reduction of false alarmsLengthening of lifespan of smoke sensorsVery low installation costsSubsequent installation possible at any timeLow operating costsApplicable for all aspirating smoke detectorsQuick clean and inexpensive solution

GBP 232.33
1

Vesda Xtralis 25mm x 12 Condensation Valve Trap with Ball Valve

KAC WBK21S11-SB Key Switch Call Point Blue - 2 Position - SPole - Key Trap In Pos 1

Carrier DC301 Money Trap Contact To Detect Removal Of Last Bank Note Self-adhesive CO Contact Black Ungraded

KAC WGK21S12-SG Green Key Switch Call Point - 2 Pos - SPole - Key Trap In Pos 1

KAC WBK21D11-SB Blue Key Switch Call Point - 2 Pos - DPole - Key Trap In Pos 1

KAC WRK21S01-SR Red Key Switch Call Point - 2 Pos - SPole - Key Trap In Pos 1

KAC WAK21S11-SA Orange Key Switch Call Point - 2 Pos - SPole - Key Trap In Pos 1

KAC WWK21S11-SW Key Switch Call Point White 2 Position SPole Key Trap in Position 1

KAC WYK21S11-SY Key Switch Call Point Yellow 2 Position SPole Key Trap in Position 1

Patol 720-212 High Temp Heat amp Flame Sensor 5730 ABS incl Mounting Bracket

Patol 720-212 High Temp Heat amp Flame Sensor 5730 ABS incl Mounting Bracket

Patol 720-212 High Temp Heat Flame Sensor 5730 ABS Including Mounting BracketThe 5730 High Temperature Transit Flame Sensor monitors high temperature materials up to 240 on highest sensitivity being transported on conveyor systems at speeds of between 0.5 and 6ms and triggers as the material reaches the ember or flame condition.The sensor employs enhanced infra-red monitoring technology that analysis the levels of IR emission in the narrow band of 4.2-4.7m. As the sensor is tuned to this band it is solar blind meaning the background and transient IR spectra are discriminated. This provides enhanced false alarm immunity.Air purging from a mains operated Air Purged Blower APB air feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window. The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5730 incorporates within the unit a series of user programmable DIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs.The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an auxiliary fault input and common fault output contact.Key FeaturesDetection of ember and flame of high temperature productAir purged system for dusty environments with air pressure monitoringFour Channels of Isolated Detectors for maximum reliabilitySingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVoting Logic Latching optionsAlarm Trip FunctionsFault Monitored with Test Reset push ButtonsField ProgrammableLocal IndicatorsComes with a Mounting Bracket

GBP 3642.24
1

Patol 710-020 Controller 5020 for Spares Only

Patol 710-020 Controller 5020 for Spares Only

Patol 710-020 Controller 5020 for Spares Only - for use with Sensor Models 5010 5012 5712The 5020 controller is directly connected to the sensor. A series of user programmable DIL switches allows option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs.The Sensor Unit is located above the materials transit path e.g. conveyor by means of the adjustable mounting bracket and aligned such that the monitored hazard passes through the sensors field of view. The height and angle of the sensor determine the width of the monitored path.The Type 5020 Control Unit provides various indications and controls related to infra-red detection alarms and fault monitoring.The control module is easily de-mountable from the housing and connects to the sensor by means of a ten core screened shielded cable. These terminations together with supply and output contact connections are via two part screw terminals thus enabling installation of the housing and site cables prior to fitment of the module. The housing has a high level of ingress protection IP67.The unit incorporates a user programmable DIL switch to set the options which include detector sensitivity setting automanual reset sequence selection and one-shot coincidence voting for the alarm and tripshutdown outputs.The sensor air pressure and signal cable connections are fault monitoredfail safe. The unit incorporates an aux. fault input common fault output contact.The 5020 Controller also includes LED indication of the four detector channels along with LED indication and relay outputs for Alarm Trip and Fault.The controller can be provided in an optional outer control panel together with power supplies battery chargers DIN rail terminals as required.Key FeaturesMaterial Fan Case - White Polyester Resin Impellors - Aluminium 1200 H14IP Rating IP44Weight 8.5Kg

GBP 2076.48
1

Eurotech EUW-MA-02 Intelligent Wireless Multi Criteria Detector cw Base amp Battery

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m Radius

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m Radius

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m RadiusThe GS903N acoustic glassbreak sensor combines high false alarmimmunity and excellent detection by recognizing the exact frequencypattern generated by glass breaking. Instead of listening for a loudsound at one or two characteristic frequencies the GS903N listens at30 points across the glassbreak frequency spectrum. This not onlyenables it to discriminate common false alarm sources but alsoensures detection of even the quietest of breaks so it can be used withblinds or light curtains. The GS903N is recommended for perimeterloops and is designed to function in occupied areas. In 24-hour loopapplications where the detector is armed all day and all night thefalse alarm technology will be pushed to its limit. Some sounds canduplicate the points on the glassbreak pattern that the GS903 detects.Install the GS903N on a perimeter loop which is armed whenever thedoor and window contacts are armed. The GS903N false alarmimmunity is best in rooms with only moderate noise. For 24-houroccupied area protection use our Shock Detectors. The GS903N maynot consistently detect cracks in glass or bullets which break throughthe glass. Glassbreak detectors should always be backed up byinterior protection.Easy to install and testAvailable in both surface and flush mount versions GS913Ninstallation is quick and easy. There are no sensitivity adjustments toworry about and a new test feature means only one trip up the ladder.Simply activate the tester next to the GS903N and the unit goes intotest mode.A unique test assures end-users that the unit is powered and ready todetect. The sensor will blink twice but will not trip when a loud hardclap is made close to the unit.Pattern Recognition TechnologyThe GS903N detects in a full 360 coverage pattern with a 7.5 mrange from detector to glass. By listening at more than 30 frequencypoints the GS903N can tell the difference between common falsealarm sources and the noise of breaking glass.Key FeaturesNo sensitivity adjustment requiredDetects through blinds and light curtainsEnd user can test sensor operation with a clap of the hands GS903NGS913NRated for all types of glass including plate laminated tempered and wiredListens for the pattern of breaking glass across the frequency spectrumConsistent detection even of soft quiet glass breaks

GBP 72.73
1

Patol ADB 500 Automatic Blowout Device for One Sampling Pipe 50-0500571-01-01P

Carrier 5822A-W Recessed ShatterPro II With quotPattern Recognition Technologyquot 360 - 75 m Radius Range

Carrier 5822A-W Recessed ShatterPro II With quotPattern Recognition Technologyquot 360 - 75 m Radius Range

Carrier 5822A-W Recessed ShatterPro II With Pattern Recognition Technology 360 - 75 m Radius RangeThe 5810 series acoustic glass break sensor combines high false alarm immunity and excellent detection by recognizing the exact frequency pattern generated by glass breaking. Instead of listening for a loud sound at one or two characteristic frequencies the 5810 series listens at 30 points across the glass break frequency spectrum. This not only enables it to discriminate common false alarm sources but also ensures detection of even the quietest of breaks so it can be used with blinds or light curtains. The 5810 series are recommended for perimeter loops and is designed to function in occupied areas. In 24-hour loop applications where the detector is armed all day and all night the false alarm technology will be pushed to its limit. Some sounds can duplicate the points on the glass break pattern that the 5810 series detects. Install the sensor on a perimeter loop that is armed whenever the door and window contacts are armed. The false alarm immunity is best in rooms with only moderate noise. For 24-hour occupied area protection use Sentrol shock detectors. The sensor may not consistently detect cracks in glass or bullets that break through the glass. Glass break detectors should always be backed up by interior protection.Easy to install and testAvailable in both surface and flush mount versions 5820 series installation is quick and easy. There are no sensitivity adjustments to worry about and a new test feature means only one trip up the ladder. Simply activate the tester next to the sensor and the unit goes into test mode.A unique test assures end-users that the unit is powered and ready to detect. The sensor will blink twice but will not trip when a loud hard clap is made close to the unit.Pattern Recognition TechnologyThe 5810 series detects in a full 360-coverage pattern with a 7.5 m range from detector to glass. By listening at more than 30 frequency points the sensor can tell the difference between common false alarm sources and the noise of breaking glass.Key FeaturesNew EZ design for quick and easy installationPattern Recognition Technology for superior detection and false alarm immunitySuitable for quiet occupied areas on a perimeter loopAutomatic test and user verification

GBP 62.60
1

Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and Ethernet

Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and Ethernet

Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and EthernetThe VESDA VLI by Xtralis is an industry first early warning aspirating smoke detection ASD system designed to protect industrial applications and harsh environments of up to 2000m2 20000 sq. ft..The VLI detector combines a fail-safe Intelligent Filter patent pending with an advanced clean-air barrier for optics protection allowing the use of absolute detection and a long detection chamber life without the need for recalibration.The Intelligent Filtereffectively reduces the level of pollution in the air sample before it enters the detection chamber which dramatically extends the operational life of the detector in harsh and polluted environments.is fully monitored therefore providing consistent sensitivity over the entire operational life of the detector.The VLI detector features a robust IP54-rated enclosure which provides protection against dust ingress and water splash. In the majority of applications this eliminates the need to use expensive external IP enclosures thus simplifying and reducing the cost of installation. The VLI detector is equipped with a powerful aspirator that provides a total pipe length of 360m 1200 ft. It is fully supported by the Xtralis ASPIRE2 VSC and VSM4 software applications which facilitate ease of pipe network design system commissioning and maintenance together with compatibility with existing VESDA installations.The AutoLearn commissioning assistant reduces setup time and ensures optimum alarm and flow thresholds in a range of environments. The VLI detector features a standardised industry BACnet over Ethernet communication protocol for remote monitoring and programming and connection to building management systems BMS and automation devices. This translates to direct cost savings on integration and monitoring. The VLI detector is inherently less prone to nuisance alarms due to the intelligent filter lint trap sub-sampling probe and secondary filter. Coupled with its modular design VLI offers a lower total cost of ownership over the life of the product.Key FeaturesSuitable for Class 1 Division 2 applications - Groups ABC DUp to 2000m2 20000 sq. ft. coverageUp to 4 inlet pipesTotal pipe length up to 360m 1200 ftFive 5 high intensity status LEDs for greater visibilityRobust absolute smoke detectionIntelligent Filter patent pendingLint Trap to capture fibrous particulatesSub-sampling Probe inertial separatorSecondary FilterClean air barrier for optics protectionReferencingAutoLearn Smoke and FlowClean Air ZeroAir-path monitoringFive 5 relays Fire Fault and 3 configurableRelays configurable as latching or nonlatchingExpandable GPI and relaysUltrasonic flow sensingXtralis VSC Xtralis VSM4 and ASPIRE2 software supportIP54 EnclosureEasy mounting through steel support bracketModular field replaceable parts for ease of servicingBACnet over EthernetLocal USB configuration portEasy cable termination accessImperial and metric pipe portsRubberized finish to external housing

GBP 6726.62
1

Patol 5710 ATEX Approved High Temperature Infrared Heat Sensor

Patol 5730 Infrared High Temperature Heat Sensor 115vAC

Patol 725-015 5712 Stainless Steel Infrared Heat Sensor without Controller