Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

10 results (0,13582 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

A&D - 24 hour blood pressure monitor with AFib screening & 360 PatientView. Includes ABPM Data Manager Software, adult cuff and large cuff & carry

A&D - 24 hour blood pressure monitor with AFib screening & 360 PatientView. Includes ABPM Data Manager Software, adult cuff and large cuff & carry

Product Properties The TM-2441 is compact & lightweight Ambulatory Blood Pressure Monitors, which incorporate our latest technology gained from over 40 years experience in developing and manufacturing precision measurement equipment. This new ABPM range was validated in accordance with the new ISO810601-2 protocol, and the blood pressure accuracy was proven to be +/-3mmHg. Key Features 24 hour ambulatory blood pressure monitoring range of devices All-in-one monitoring solution: Ambulatory (ABPM), Home (HBPM), Office (OBP), Automatic Night Blood Pressure (ANBP), Automatic Self Blood Pressure (ASBP) measurement/monitoring Light weight – from 122 grams (excluding batteries) Compact – only 66mm x 24.5mm x 95mm (WxHxD) Oscillometric measuring method AFib+ Irregular Heartbeat detection (IHB) and AFib screening Automatically adjusts: Proper Cuff Pressure, Exhaust, End of Measurement ‘PatientView 360’ – Multi-sensor tracking of activity, temperature, air pressure Battery Power – only 2 alkaline or Ni-MH AA batteries Multiple measurement intervals – adapts to patient’s and healthcare professional’s exact requirements Bluetooth (BLE) or USB cable data output to computer or printer Local memory recording for up to 600 sets of data 24-hour clock and calendar Waterproof and Dustproof to IP22 Standard – designed   ‘with the patient in mind’ Can be integrated into an Electronic Patient Record System (EPR) Secure screw thread cuff connection – to avoid accidental disconnection/error readings 2 Display options: LCD – self measurement display, OLED – Ambulatory monitoring display 4 cuff options ranging from 15cm to 50cm Accuracy: blood pressure +/-3mmHg; pulse +/-5% Clinically Validated to ISO810601-2

GBP 1794.00
1

A&D - Disposable Arm Sleeve 2x200 pcs for blood pressure monitors

A&D - UA-651SL - Upper arm blood pressure monitor with Semi-Large cuff

A&D - UB-543 - Wrist blood pressure monitor with AFib screening

A&D - UB-543 - Wrist blood pressure monitor with AFib screening

Product Properties A clear step towards a healthy lifestyle, the monitor benefits from extremely accurate Oscillometric BP measurement, first developed and patented by A&D back in 1984. Taking repeatable, accurate readings using the A&D UB-543 Automatic Wrist Monitor is made simple with A&D technology: A&D Correct Position Guidance technology. The UB-543 has a simple blue/orange display indicator to help guide the user to ensuring the device is ‘seated’ correctly first time, every time. If the reading is taken without the arm being in the correct position, this can affect the accuracy of the reading. A&D World Health Organisation Blood Pressure Indicator. A&D first pioneered the simple ‘traffic light’ indicator system for blood pressure monitors in 2003. This simple indicator helps the user quickly identify whether their readings are low, normal or high based on the World Health Organisation (WHO) guidelines. The UB-543 is clinically validated to the world recognized European Hypertension Society (ESH) guidelines so the user can have complete confidence in their readings. The A&D UB-543 also benefits from the dual user mode, allowing the recording of up to 60 recordings for two users. It also incorporates the average value feature of the stored data, as well as the WHO Blood pressure classification indicator to allow the users to better control their management programs. It also boasts A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening/Circadian Rhythm analysis technology, pioneered by A&D in 2001 and now found on most of our range of blood pressure monitors. This A&D ground breaking technology is now used worldwide assisting in the opportunistic detection of arrhythmias – which include AFib (or Atrial Fibrillation). The Japanese design and reliable quality of the UB-543 allows A&D to offer the user a 5 Year warranty (excluding batteries and Cuff). Key Features Simple to use, easy one button operation Lightweight, compact design Correct Position Guidance technology Drawing on A&D’s industry leading measuring accuracy 2 x 60 readings memory recording – for recording trending Dual user mode Average reading function Extra-large, easy to read LCD display Fast measurement Clock and Calendar Carry case World Health Organisation (WHO) Blood Pressure Classification Indicator A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening Clinically Validated 5 year warranty

GBP 83.94
1

A&D - UB-533 - Wrist blood pressure monitor with AFib screening

A&D - UB-533 - Wrist blood pressure monitor with AFib screening

Product Properties A clear step towards a healthy lifestyle, the monitor benefits from extremely accurate Oscillometric BP measurement, first developed and patented by A&D back in 1984. Taking repeatable, accurate readings using the A&D UB-533 Automatic Wrist Monitor is made simple with A&D technology: A&D Correct Position Guidance technology. The UB-533 has a simple blue/orange display indicator to help guide the user to ensuring the device is ‘seated’ correctly first time, every time. If the reading is taken without the arm being in the correct position, this can affect the accuracy of the reading. A&D Movement Error Indicator technology. The UB-533 display will show the movement error indicator if movement is detected. If there is movement whilst taking a reading can affect the accuracy of the reading. A&D Cuff Error Indicator technology. The UB-533 display will show the cuff error indicator if the cuff is not correctly ‘seated’. If a cuff is incorrectly ‘seated’, this can affect the accuracy of the reading. A&D World Health Organisation Blood Pressure Indicator. A&D first pioneered the simple ‘traffic light’ indicator system for blood pressure monitors in 2003. This simple indicator helps the user quickly identify whether their readings are low, normal or high based on the World Health Organisation (WHO) guidelines. The UB-533 is clinically validated to the world recognized European Hypertension Society (ESH) guidelines so the user can have complete confidence in their readings. The A&D UB-533 also benefits from the dual user mode, allowing the recording of up to 60 recordings for two users. It also incorporates the average value feature of the stored data, as well as the WHO Blood pressure classification indicator to allow the users to better control their management programs. It also boasts A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening/Circadian Rhythm analysis technology, pioneered by A&D in 2001 and now found on most of our range of blood pressure monitors. This A&D ground breaking technology is now used worldwide assisting in the opportunistic detection of arrhythmias – which include AFib (or Atrial Fibrillation). The Japanese design and reliable quality of the UB-533 allows A&D to offer the user a 5 Year warranty (excluding batteries and Cuff).   Key Features Simple to use, easy one button operation Lightweight, compact design Correct Position Guidance technology Drawing on A&D’s industry leading measuring accuracy Movement Error Indicator – to ensure accurate readings Cuff Error Indicator – to ensure accurate readings 2 x 60 readings memory recording – for recording trending Dual user mode Average reading function Extra-large, easy to read LCD display Fast measurement Clock and Calendar Carry case World Health Organisation (WHO) Blood Pressure Classification Indicator A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening Clinically Validated 5 year warranty

GBP 77.94
1