Aico RadioLINK Panel Interface Ei413
Aico RadioLINK Panel Interface Ei413The Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and fire alarmsecurity alarm panels. The module will decode aFire Carbon Monoxide and fault signals from RadioLINK devices and activate the Panel accordingly and will also work the other way activating the domestic alarms if it receives a signal from the Panel.The module is powered either directly from the Panel Systemor from an external source.Operation of the Ei413 RadioLINK Panel Interference ModuleOn receiving a Volt-free switched hardwired signal from the panel the module will transmit a RadioLINK alarm signal to activate the alarms in the systemIf a fire alarm has activated the module will recognise the signal as a fire and switch the relevant contacts to activate the panelIf a Carbon Monoxidealarm has activated the module will recognise the signal as a Carbon Monoxideleak and switch the relevant contacts to activate the panelTechnical SpecificationEliminate the need for any cabling between the Ei413 and the smokeheatCO alarms used in the system.The Ei413 is conformant to EN300220-1 RF Performance in accordance with EN300220-2 and EN301489-1 EMC referencing EN301489-3.The unit is powered from the alarm panel and requires 11 to 30VDC. Unit current rating 15mA Standby 60mA Alarm Max.The unit has three sets Normally Open Normally Closed and Common of built-in wiring contacts for connection to the panel rated at 30V 1 Amp. On the contacts closing the unit will dependent on which set of contacts are connected indicate a fire CO leak or fault to the panel. The unit also has a Normally Open volt-free set of contacts to link from the panel to it so if the panel is activated the unit will transmit a RadioLINK signal to the alarms in the system to activate them they will sound.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal.Up to 12 RadioLINK units can be used in one system. Range may be a limiting factor.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Units are in factory code when received they will communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code Switch on all RadioLINK units in the system see the instructions supplied with the other RadioLINK units being used. The LED indicator on the front cover of the Ei413 will flash blue slowly this indicates that it is transmitting its unique serial number to all other RadioLINK units in House Code. After a short time the unit will flash to indicate the number of units in the system 2 flashes 2 units 3 flashes 3 units etc.. The Ei413 will return to normal standby mode automatically after 15 minutes. Pressing the House Code Switch again will return it to normal standby immediately.Designed for surface mounting or can be fitted into certain alarm panels provided the casing is not a metallic construction which may restrict RF signals.Dimensions 88mm x 88mm x 28mm.Weight 150g.Ambient Temperature Range 0C to 40C.5 year guarantee.Manufactured in Ireland.