Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

3 results (0,14719 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aico RadioLINK Manual Call Point Ei407

Aico RadioLINK Manual Call Point Ei407

Aico RadioLINK Manual Call Point Ei407This call point is powered by a tamper proof sealed inlithium cell giving a completely wire free installation with a 10-year life.The front plate is made from a non-breaking plastic that means if the callpoint is used you can simply reset the plate rather than having to replace it.The Ei407 connects wirelessly using RadioLINKinterconnection technology so once in place you will need to House Code theswitch into the alarm system.Operation The indicator will flash green every 40 seconds to indicatethat the battery is healthyThe indicator will flash amber every 9 seconds to indicatethat the batteries are depletedKey FeaturesAllows for remote triggering of an alarm systemNon-breaking re-settable front platesContains 10-year lithium cell for completely wire freeinstallationConnects wirelessly with all other Aico wirelessinterconnection productsTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarmsEliminates the need for any cabling between the Ei407 and the smoke andor heat alarms within the systemFeatures built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply. If the LED flashes amber every 40 seconds this indicates a depleted battery and the complete unit must be replacedThe product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002-08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt 12000Radio frequency 868MHz in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegalUp to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance also see section 7Range the type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass throughLow battery warning signal LED indicator flashes amber every 40 seconds to indicate depleted battery if this occurs the complete unit should be replacedSimply key to rest the unit no broken glassReplacement key MCRSK availableAmbient temperature range 4c to 40c. Humidity range 0 to 90 relative humidityExternal alarm RadioLINK signal operates sounder on any smoke alarm with a RadioLINK in the systemUnits are in factory code when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After house coding they will only communicate with other units coded at the same timeHouse Code Operate the red House Code switch on the back of the unit. At the same time put all other RadioLINK units in the system into House Code see relevant instruction leaflets. The red LED on the front cover will flash rapidly to indicate that it is in House Code. Each RF base will learn the serial numbers of all units in the system any other RadioLINK units. The number of flashes of the amber light on the RF units indicates the number of alarms in the system. All units will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return them to normal standby immediatelyThe Ei407 can be incorporated into a system consisting of any additional RadioLINK componentsDimensions 85mm x 85mm x 57mm deep including mounting boxWeight 240g including packaging5 year guaranteeManufactured in Ireland

GBP 58.33
1

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee

GBP 61.67
1

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RFTheEi170RF is a mains powered with rechargeable battery back up alarm kitfor the deaf and hard of hearing. Thekit contains aXenon strobe lightthat provide and plug in vibrating pillow pad that will activate when the interconnected alarms are triggered to alert theuser tothe danger.TheEi170RF kit is compatible with the3000Multi-Sensor Fire Alarm Ei2110e160e Seriesalarms and 140RC Series smoke and heat alarms along with any interconnected Carbon Monoxide alarms. This kit links into the alarm system usingRadioLINK wireless interconnection technology making it easier to add into a system and causing less disruption to the occupants on installation.An integral Test button is also present on the front of the unit allowing an easy means of testing the strobe vibration pad and the RadioLINK enabled alarms in the system.As with other RadioLINK products the Ei170 Alarm Kit for the Deaf and Hard of Hearing will need to belinked into the alarm system or House Coded. View ourstep by step guide to House Coding here.Technical Specification A strobe and vibrating pillow pad kit designed to give warning of fire to deaf and hard of hearing occupants. For use with30002110e160eand 140RC Series smoke and heat alarms when used with aRadioLINK baseRadioLINK moduleor theSmartLINKmoduleRadioLINK Carbon MonoxideCO alarms. It can also be used with all other RadioLINK devicesancillaries including the 600 Series RadioLINK smoke and heat alarms.Eliminates the need for any cabling between the Ei170 RF and the smoke heat andor CO alarms used in the system.Requires 230V AC 50Hz mains power supply.The unit has a built-in high-intensity Xenon strobe flash rate 0.8Hz with a wide light output angle.Built-in long life sealed lead acid rechargeable battery to provide back-up power in the event of mains failure. Standby capacity 7 days followed by 15 minutes alarm lifespan 5 years in normal use. The battery is connected by plugging it into the socket in the bottom of the battery box.Comprehensive indicating lights on front of the unitPower Constant green to indicate mains is present flashes amber every 4 seconds with mains absent.Alarm red Flashes every second when the unit has been triggered.Fault amber Flashes every 4 seconds if a fault is detected with panelvibration pad. Flashes every 4 seconds if rechargeable back-up battery is depleted or faulty.RF status blue Illuminates when RF signal is being sent flashes in House Code mode to indicate the number of units learned. Flashes every 40 seconds if RadioLINK smoke alarms have a low battery.Mains transformer is mounted in separate and hard-wired to the strobe unit with 4m of low voltage cable. Supplied with 2m of mains cable and pre-wired 13 amp plug with a 3 amp fuse.Integrated Test button on the front of the unit. Pressing this checks strobe and control circuitry and also send out a RadioLINK alarm signal to other units in the system.The vibrating pillow pad is suitable for mounting under mattresses or pillows and produces strong pulsed vibrations suitable for waking sleepers. Supplied with locking plug and 5m of pre-wired cable.Connecting sockets on rear of unit as followsVibration Pad socket Locking socket JST type VHR-2N. Is pulsed when unit is in alarm.Auxiliary sockets Two auxiliary sockets are available on the rear of the unit to allow connection of additional strobes etc. Locking sockets JST type VHR-2N. Each provides 12V200mA when unit is in alarm. Can be used for any of the following Auxiliary strobe Ei178 auxiliary vibration pad Ei174 or for triggering a radio pager.A clock input socket is also available. This is for use will alarm clocks that have a 3.5mm mono jack output and saves the need for multiple vibration pads. An input of 5-12V AC or DC mains isolated will turn on the vibration pad constant vibration pattern but will not activate the strobe or auxiliary sockets.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal. Complies with EN300220-2V2.1.1.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance.

GBP 279.71
1