Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

10 results (0,18252 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aico EI3018EF Eco-Fit Pack - CO Alarm - 230V With 10 Year Rechargeable Lithium Back-up

Aico Ei3016 230v 3000 Series Optical Smoke Alarm

Aico Ei3016 230v 3000 Series Optical Smoke Alarm

Aico Ei3016 230v 3000 Series Optical Smoke AlarmThe Ei3016 Optical Smoke Alarm contains a high-performance optical smoke sensor which is best for detecting slow smoldering fires. In addition the smoke chamber design integrated insect screen and unique automatic dust compensation reduce the risk of false alarms. The Ei3016 runs on 230V AC mains power. In the event of mains failure the 10 Year built in tamper-proof rechargeable lithium cells will provide back-up supply and continuous operation.The Ei3016 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The Ei3016 self-checks its sensor battery and internal circuitry every 48 seconds. Any fault condition found will be indicated by a combination of yellow LED flashes andor audible beeps. The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED.The alarm is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesContains a high-performance optical sensorMains powered with 10-year rechargeable Lithium cell back-upCompatible with interconnection and monitoring technologyAudioLINK TM Data extraction technologyDust compensation - unique self-monitoring mechanismEasi-Fit base10 Year lifeSensor Type OpticalSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensor electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red alarm silence mode memory. Yellow fault eventMemory Records last alarm eventFixing easi-fit base suppliedOperating Temperature -10C to 40CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardant

GBP 72.89
1

Aico Ei208 Carbon Monoxide CO Alarm

Aico Ei3014 230v 3000 Series Heat Alarm

Aico Ei3014 230v 3000 Series Heat Alarm

Aico Ei3014 230v 3000 Series Heat AlarmSuitable for detecting Heat in both the kitchen or garagethe Ei3014 Heat Alarm contains our tried and tested high-performance ThermistorHeat sensor. The Thermistor has been designed using a smaller thermal massproviding a faster alarm response when the trigger temperature of 58C isreached. Best for detecting heat build-up from large flaming fires it candifferentiate from smoke or steam to drastically reduce false alarms.The Ei3014 Heat Alarm is SmartLINK compatible Simply plugin an Ei3000MRF module for wireless interconnection data extraction andreal-time notifications of alarm activations and events via the SmartLINKGateway and Portal.The Heat Alarm contains AudioLINKtechnology which allowsyou to extract real time data from the alarm using its sounder directly to asmartphone or tablet via an App. A simple to read report is generateddisplaying details such as activation dates sensor status and alarm life thatcan be emailed to help form part of property records.The Ei3014 Heat Alarm is fully compatible with all otherAico alarms and accessories whether a system needs upgrading or an existingsystem needs expanding and works with either hard-wired RadioLINK or hybridinterconnecting systems.Key FeaturesContains a fast response Thermistor Heat sensorMains powered with a 10-year rechargeable lithium cellback-upAdd an Ei3000MRF SmartLINK module for wirelessinterconnection and data extractionCompatible with other Aico mains powered devicesBuilt-in AudioLINK data extraction technologyGrade D1 and compliant with Scottish legislationSupplied with an easy-fit base10 Year Guarantee

GBP 73.07
1

Aico RadioLINK Carbon Monoxide Smoke Alarm Ei208WRF

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee

GBP 61.67
1

Aico Ei3018 230v 3000 Series Carbon Monoxide Alarm

Aico Ei3018 230v 3000 Series Carbon Monoxide Alarm

Aico Ei3018 230v 3000 Series Carbon Monoxide AlarmThe Ei3018 is a Carbon Monoxide CO Alarm powered by 230V AC mains power and has built in tamper proof rechargeable lithium cells that act as a battery back up in the event of mains failure. These rechargeable lithium cells are designed to last the life of the CO alarm. The Ei3018 has a high performance proven electrochemical sensor 10 year life to sense CO presence. The sensor is individually calibrated and tested in CO gas to ensure accuracy. In alarm the flash rate of the red LED indicates the level of CO detected.The Ei3018 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The Ei3018 can operate as a standalone alarm or can be interconnected either by hard-wire or wirelessly using the EI3000MRF module enabling it to communicate with compatible alarms and accessories. Up to 12 devices can be interconnected.The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED. The alarm is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesSensor Types Electrochemical cell10 year lifeEasi-fit baseAudioLINK data extraction technologyCompatible with other Aico mains powered devicesAdd an Ei3000MRF module for wireless interconnection and data extractionMains powered with 10 year rechargeable lithium cell back-upContains our proven Electrochemical CO sensorSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensors electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red pre alarm alarm silence mode memory. Yellow fault eventMemory Records last alarm eventOperating Temperature -10C to 35CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardantDimensions Product 150mm x 55mmDimensions Boxed 180mm x 155mm x 62mmWeight 310g product only 376g boxedGuarantee 5 years

GBP 89.60
1

Aico RadioLINK Panel Interface Ei413

Aico RadioLINK Panel Interface Ei413

Aico RadioLINK Panel Interface Ei413The Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and fire alarmsecurity alarm panels. The module will decode aFire Carbon Monoxide and fault signals from RadioLINK devices and activate the Panel accordingly and will also work the other way activating the domestic alarms if it receives a signal from the Panel.The module is powered either directly from the Panel Systemor from an external source.Operation of the Ei413 RadioLINK Panel Interference ModuleOn receiving a Volt-free switched hardwired signal from the panel the module will transmit a RadioLINK alarm signal to activate the alarms in the systemIf a fire alarm has activated the module will recognise the signal as a fire and switch the relevant contacts to activate the panelIf a Carbon Monoxidealarm has activated the module will recognise the signal as a Carbon Monoxideleak and switch the relevant contacts to activate the panelTechnical SpecificationEliminate the need for any cabling between the Ei413 and the smokeheatCO alarms used in the system.The Ei413 is conformant to EN300220-1 RF Performance in accordance with EN300220-2 and EN301489-1 EMC referencing EN301489-3.The unit is powered from the alarm panel and requires 11 to 30VDC. Unit current rating 15mA Standby 60mA Alarm Max.The unit has three sets Normally Open Normally Closed and Common of built-in wiring contacts for connection to the panel rated at 30V 1 Amp. On the contacts closing the unit will dependent on which set of contacts are connected indicate a fire CO leak or fault to the panel. The unit also has a Normally Open volt-free set of contacts to link from the panel to it so if the panel is activated the unit will transmit a RadioLINK signal to the alarms in the system to activate them they will sound.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal.Up to 12 RadioLINK units can be used in one system. Range may be a limiting factor.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Units are in factory code when received they will communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code Switch on all RadioLINK units in the system see the instructions supplied with the other RadioLINK units being used. The LED indicator on the front cover of the Ei413 will flash blue slowly this indicates that it is transmitting its unique serial number to all other RadioLINK units in House Code. After a short time the unit will flash to indicate the number of units in the system 2 flashes 2 units 3 flashes 3 units etc.. The Ei413 will return to normal standby mode automatically after 15 minutes. Pressing the House Code Switch again will return it to normal standby immediately.Designed for surface mounting or can be fitted into certain alarm panels provided the casing is not a metallic construction which may restrict RF signals.Dimensions 88mm x 88mm x 28mm.Weight 150g.Ambient Temperature Range 0C to 40C.5 year guarantee.Manufactured in Ireland.

GBP 76.93
1

Aico RadioLINK Manual Call Point Ei407

Aico RadioLINK Manual Call Point Ei407

Aico RadioLINK Manual Call Point Ei407This call point is powered by a tamper proof sealed inlithium cell giving a completely wire free installation with a 10-year life.The front plate is made from a non-breaking plastic that means if the callpoint is used you can simply reset the plate rather than having to replace it.The Ei407 connects wirelessly using RadioLINKinterconnection technology so once in place you will need to House Code theswitch into the alarm system.Operation The indicator will flash green every 40 seconds to indicatethat the battery is healthyThe indicator will flash amber every 9 seconds to indicatethat the batteries are depletedKey FeaturesAllows for remote triggering of an alarm systemNon-breaking re-settable front platesContains 10-year lithium cell for completely wire freeinstallationConnects wirelessly with all other Aico wirelessinterconnection productsTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarmsEliminates the need for any cabling between the Ei407 and the smoke andor heat alarms within the systemFeatures built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply. If the LED flashes amber every 40 seconds this indicates a depleted battery and the complete unit must be replacedThe product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002-08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt 12000Radio frequency 868MHz in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegalUp to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance also see section 7Range the type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass throughLow battery warning signal LED indicator flashes amber every 40 seconds to indicate depleted battery if this occurs the complete unit should be replacedSimply key to rest the unit no broken glassReplacement key MCRSK availableAmbient temperature range 4c to 40c. Humidity range 0 to 90 relative humidityExternal alarm RadioLINK signal operates sounder on any smoke alarm with a RadioLINK in the systemUnits are in factory code when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After house coding they will only communicate with other units coded at the same timeHouse Code Operate the red House Code switch on the back of the unit. At the same time put all other RadioLINK units in the system into House Code see relevant instruction leaflets. The red LED on the front cover will flash rapidly to indicate that it is in House Code. Each RF base will learn the serial numbers of all units in the system any other RadioLINK units. The number of flashes of the amber light on the RF units indicates the number of alarms in the system. All units will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return them to normal standby immediatelyThe Ei407 can be incorporated into a system consisting of any additional RadioLINK componentsDimensions 85mm x 85mm x 57mm deep including mounting boxWeight 240g including packaging5 year guaranteeManufactured in Ireland

GBP 58.33
1

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay Rechargeable Battery Back-up Ei428The Ei428 is a mains powered relay module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.The module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easi-fit or RadioLINK base. However a cover Ei128COV is available if needed and containsa set of volt free contacts as standard.The replay module can beconfigured to give a 230V output or a 24V output using an external 24V supplyOperation of Ei428 RadioLINK Relay ModuleOn receiving a RadioLINK signal from one of the alarms in the system the relay contacts will be operated causing a signal to be sent to the system to which it is connectedThe indicator on the cover will show a constant green light when the mains power is connected.Technical SpecificationA relay module with cover to allow flexibility in siting.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei428 and the smoke heat and CO alarms used in the system.Requires 230V AC Mains Power Supply Green LED to indicate mains power is present.Features built-in tamper proof Rechargeable Vanadium Pentoxide lithium standby cells capable of lasting at least 10 years and powering the module initially for at least 2 months in the event of mains power failure. The cell manufacturer endorses a minimum 10-year life expectation for the rechargeable cells which are activated by operating the battery switch inside the module.The product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002 08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt.12000.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Low back-up warning signal LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.Volt free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power or on back-up cells in the event of mains failure.A RadioLINK Manual Call Point Ei407 and remote control switches Ei450 Ei412 and Ei411H are also available for use in the system. See separate specification sheets for further information.Features 1 x 25mm trunking for for surface wiring and centre knockout for recess wiring.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 140mm diameter x 27mm depth weight inclusive of packaging 220g.5 year guarantee.Manufactured in Ireland.Key FeaturesDesigned for use with all RadioLINK Professional alarms and accessoriesRechargeable Lithium battery back-upVolt-free contacts as supplied for multiple usesCan be configured to switch a 230V or 24V outputTrunking knock-outs for easy and neat wiringContinuous or Pulse operation5 Year Guarantee

GBP 98.36
1