Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

111 results (0,14076 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo SA7800-870APO Touch Screen Portable Test Set Unit

Apollo SA7800-870APO Touch Screen Portable Test Set Unit

Apollo SA7800-870APO Touch Screen Portable Test Set UnitThe Apollo Test Set is a portable test unit featuring a touch screen display capable of providing several functions in interrogating and controlling all devices connected to the unit either individual devices or compete circuits of analogue addressable devices in the Apollo ranges CoreProtocol Discovery and XP95.How does the product workThe standard view allows devices to be scanned and controlled through the manipulation of the devices output bits. Devices can also be self-tested using the test set and the different functionality modes can also be controlled. The unit may be powered from an AC mains charger unit or from its own internal batteries. The loop or individual address can be connected to the unit using loop connection ports which are located on the top of the device.What problem does this help solveThe device also has the functionality to test the diagnostics and integrity of the loop to find earth faults etc. The device offers fault finding capabilities which allows for time spent on site to be cut down during the commissioning stage of the system installation. The result of this is time reduced on site for the end user which reduces the overall costs of installing Apollo systems.Kit ContainsThe Apollo Test Set UnitA universal chargerTwo red connector cablesTwo black connector cablesTwo yellow connector cablesGreen connector cableXPERT 8 Intelligent Mounting BaseCarry strapQuick Start Guide

GBP 828.46
1

Apollo Discovery Red Open-Area Voice Sounder Beacon - 58000-030APO

Apollo SA5500-300APO Open-Area Sounder Red Body

Apollo SA5500-300APO Open-Area Sounder Red Body

Apollo SA5500-300APO Open-Area Sounder Red BodyThe Intelligent Open-Area Sounder is designed for use inopen-areas and can be connected to anyCoreProtocol Discovery or XP95 system. The Intelligent Open-Area Sounder includes features such as groupand individual control status reporting and selectable tone and volume settings all configuredthrough the fire control panel.The right tone for the installationThe Intelligent Open-Area Sounder offers a choice of 15 evacuationtones including the standard Apollo evacuation tone. A tone is selected during commissioning inorder to suit local regulations or customs.Whichever evacuation tone is selected there is a secondary tonewhich may be used for alerting or warning of a possible evacuation. The right level of soundThe sounder is set during commissioning to one of sevenlevels of sound the highest level being nominally 101 dbA at 1m. At lessthan 60 dbA the lowest level falls outside the scope of the EN54 standard. Ithas been included to provide a very local warning for the use of personnel in particularenvironments such as nurse stations in hospitals.AddressingThe Open-Area Alarm Devices respond to their own individual address which is set via the appropriate XPERTaddress card. Group address and tones on CoreProtocol systems are set using the fire control panel.Location-specific volume settingDetectors and sounder indicators are installed in manydifferent types of environment. When configuring the Intelligent Open-Area Sounder devicesthe adjustment of the volume can be done at the point of installation. The commissioning engineer simply sets the control panel to Set-upand then walks from one device to the next to set the required volume using amagnetic wand. When all devices have been set the engineer simply presses abutton on the control panel which then registers all the individual volumesettings.Key FeaturesAdjustable tone and volume 15 tone pairs seven volume levelsSoftware defined group addressing with up to 16 group addressesAlarm switching by individual device by group address or ofall individual devices on the loopBuilt-in controllable isolatorSet-up and testing of devices at point of installationUnique acoustic self-test

GBP 46.96
1

Apollo SA5501-300APO Open-Area Sounder White Body

Apollo SA5501-300APO Open-Area Sounder White Body

Apollo SA5501-300APO Open-Area Sounder White BodyThe Intelligent Open-Area Sounder is designed for use inopen-areas and can be connected to anyCoreProtocol Discovery or XP95 system. The Intelligent Open-Area Sounder includes features such as groupand individual control status reporting and selectable tone and volume settings all configuredthrough the fire control panel.The right tone for the installationThe Intelligent Open-Area Sounder offers a choice of 15 evacuationtones including the standard Apollo evacuation tone. A tone is selected during commissioning inorder to suit local regulations or customs.Whichever evacuation tone is selected there is a secondary tonewhich may be used for alerting or warning of a possible evacuation. The right level of soundThe sounder is set during commissioning to one of sevenlevels of sound the highest level being nominally 101 dbA at 1m. At lessthan 60 dbA the lowest level falls outside the scope of the EN54 standard. Ithas been included to provide a very local warning for the use of personnel in particularenvironments such as nurse stations in hospitals.AddressingThe Open-Area Alarm Devices respond to their own individual address which is set via the appropriate XPERTaddress card. Group address and tones on CoreProtocol systems are set using the fire control panel.Location-specific volume settingDetectors and sounder indicators are installed in manydifferent types of environment. When configuring the Intelligent Open-Area Sounder devicesthe adjustment of the volume can be done at the point of installation. The commissioning engineer simply sets the control panel to Set-upand then walks from one device to the next to set the required volume using amagnetic wand. When all devices have been set the engineer simply presses abutton on the control panel which then registers all the individual volumesettings.Key FeaturesAdjustable tone and volume 15 tone pairs seven volume levelsSoftware defined group addressing with up to 16 group addressesAlarm switching by individual device by group address or ofall individual devices on the loopBuilt-in controllable isolatorSet-up and testing of devices at point of installationUnique acoustic self-test

GBP 46.96
1

Apollo SA5501-320APO Open-Area VID White Body White Flash

Apollo Loop-Powered Amber Visual Indicator - 55000-879APO

Apollo SA5501-321APO Open-Area VID White Body Red Flash

Apollo Loop-Powered Clear Visual Indicator 55000-878APO

Apollo SA5500-351APO Open-Area Sounder VID Red Body Red Flash

Apollo SA5500-350APO Open-Area Sounder VID Red Body White Flash

Apollo SA5501-350APO Open-Area Sounder VID White Body White Flash

Apollo Integrated Base Sounder without Isolator 45681-278APO

Apollo SA5501-351APO Open-Area Sounder VID White Body Red Flash

Apollo XP95 Beacon Base with Isolator - 45681-333APO

Apollo XP95 Beacon Base with Isolator - 45681-333APO

Apollo XP95 Beacon Base with Isolator - 45681-333APOThe Visual Indicator Base is a loop-powered visual indicator combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The visual indicator base can be used with either a detector fitted or with a cap as a stand-alone alarm device. The base is loop powered so needs no external power supply. It operates at 1728V DC and is polarity-sensitive.Device AddressingThe Base responds to its own individual address set with a DIL switch. It also responds to a group address set by means of a 4-segment DIL switch and to a synchronisation address which is embedded in the unit. Addresses 1 to 111 are used exclusively for individual addresses addresses 112 to 126 are used for group addressing while the synchronisation address to which all units respond is 0. Any Beacon Base on a loop may be freely assigned to a group. The address for any group must be chosen from the range 112126.Addresses 112126 may be used as individual addresses but only if the 4-segment DIL switch is not used ie group addressing is disabled. If the 4-segment DIL switch were set to any number other than the default 127 a pre-set analogue value of 4 would be transmitted to indicate a fault. The Base is normally polled by its individual address. It responds as described below. It is recommended that the synchronisation address 0 be sent by the control panel at regular intervals to align the internal clock of all sounders. The result is that the beacons are synchronised with each other when activated.Key FeaturesVisual indicator flash rate of once per secondSynchronisation of visual indicator flashIndividual and group addressingUnique visual indicator self-testLoop-poweredBuilt-in Isolator

GBP 35.83
1

Apollo SA4700-102APO Intelligent Input Output Unit

Apollo SA5000-202APO XPERT 8 Intelligent Mounting Base - Red

Apollo XPA-CB-14019-APO XPander Multisensor Detector with Sounder Base

Apollo XPA-CB-14027-APO XPander Multisensor Detector with Sounder VID Base White Flash

Apollo SA4700-104APO Intelligent Twin Input Output Unit

Apollo Discovery Red Open-Area Voice Sounder - 58000-010APO

Apollo XPander Combined Sounder Base XPA-WB-14036-APO

Apollo XPander Combined Sounder Beacon Base XPA-WB-14037-APO

Apollo XPA-MC-14101-APO XPander Manual Call Point - Integral Radio Base

Apollo Blank XPert Card for XPander Wireless Range -Red 29600-399

Apollo Blank XPert Card for XPander Wireless Range -Red 29600-399

Apollo Blank XPert Card for XPander Wireless Range RedSpare singular blank XPERT card in red for the XPander range. XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop.XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Brand Featuresmodern styling loop-powered interface operating on 868MHz wireless addresses seen by control panel as normal addresses radio base with wireless circuitry and battery compartment chamber designed to inhibit dirt penetration and thus reduce false alarms automatic drift compensation with DirtAlert warning algorithms for transient alarm rejection FasTest reduces time taken to test detectors remote test facility 3-5 years battery lifeProduct InformationAddress card supplied with all bases. Using a coding guide pips are removed to set the address of the inserted device.Key FeaturesSimplifies and speeds up installation and commissioningAddress remains the same no matter how often detectors are replacedUses patented proven technologyFlexibility to create any address

GBP 0.24
1

Apollo XPander Manual Call Point Integral Radio Base - XPA-MC-14006-APO