Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

28 results (0,61523 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo RW1300-010 Reach AV Base Cap - White

Apollo RW1300-020 Reach AV Base Cap - Red

Apollo Cat O. XP95 VAD Base with Isolator 45681-709APO

Apollo RW1300-260APO REACH Sounder VAD Base - Black

Apollo RW1300-110APO Reach Sounder Base

Apollo RW1300-211APO Reach Sounder VAD Base Red Flash C-3-10

Apollo RW1300-210APO Reach Sounder VAD Base White Flash C-3-15

Apollo Auto-Aligning Beam Detector 8-50m 29650-069

Apollo Auto-Aligning Beam Detector Additional Head 8-50m 29650-070

Apollo Mounting Plate for 4 Prisms 100m 29600-529

Apollo Auto-Aligning Beam Detector Extension Kit 100m 29600-526

Apollo Beam Detector Surface Mounting Plate for Prisms 29600-528

Apollo Universal Bracket for Beam Detector Heads and Prisms 29600-527

Apollo Mounting Plate for 1 Prism 8-50m 29600-530

Apollo RW1000-600APO Reach Optical Smoke Detector

Apollo Discovery Marine Sounder Visual Indicator Base - 45681-394MAR

Apollo Orbis BR I.S. Heat Detector ORB-HT-51149-APO

Apollo XP95 Beacon Base with Isolator - 45681-333APO

Apollo XP95 Beacon Base with Isolator - 45681-333APO

Apollo XP95 Beacon Base with Isolator - 45681-333APOThe Visual Indicator Base is a loop-powered visual indicator combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The visual indicator base can be used with either a detector fitted or with a cap as a stand-alone alarm device. The base is loop powered so needs no external power supply. It operates at 1728V DC and is polarity-sensitive.Device AddressingThe Base responds to its own individual address set with a DIL switch. It also responds to a group address set by means of a 4-segment DIL switch and to a synchronisation address which is embedded in the unit. Addresses 1 to 111 are used exclusively for individual addresses addresses 112 to 126 are used for group addressing while the synchronisation address to which all units respond is 0. Any Beacon Base on a loop may be freely assigned to a group. The address for any group must be chosen from the range 112126.Addresses 112126 may be used as individual addresses but only if the 4-segment DIL switch is not used ie group addressing is disabled. If the 4-segment DIL switch were set to any number other than the default 127 a pre-set analogue value of 4 would be transmitted to indicate a fault. The Base is normally polled by its individual address. It responds as described below. It is recommended that the synchronisation address 0 be sent by the control panel at regular intervals to align the internal clock of all sounders. The result is that the beacons are synchronised with each other when activated.Key FeaturesVisual indicator flash rate of once per secondSynchronisation of visual indicator flashIndividual and group addressingUnique visual indicator self-testLoop-poweredBuilt-in Isolator

GBP 35.83
1

Apollo XP95 Manual Call Point without Isolator - 55100-905APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201The Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the L1 IN and L1 OUT wiring terminals.This base can only be used with compatible control equipment.OperationAll detectors in the Series 65 range fit into Series 60 standard mounting bases. The bases are of 100mm diameter and have five terminals marked according to their function Line 1 in line 1 out line 2 in and out remote indicator negative earth. Detectors are polarity insensitive so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors.The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 51 to 69mm. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connectorContinues to work during unauthorised removal of detectorsBrand FeaturesWide-operating voltage of 933 V DCWide-operating and storage temperature of -20C to 60CCan be used on security systemsElectrically and mechanically compatible with Series 60Proven detection performance

GBP 2.60
1

Apollo XP95 Optical Smoke Detector 55000-600APO

Apollo XP95 Optical Smoke Detector 55000-600APO

Apollo XP95 Optical Smoke Detector - 55000-600APOThe XP95 range of analogue addressable fire detectors uses tried and trusted technology to give the best performance and has unique features that benefit the installer and the end user. It is suitable for medium-to-large applications with simple installation requirements. As it operates using digital communication XP95 has a high immunity from corruption and is therefore often preferred in a large system where life safety is critical. XP95 products are frequently used in commercial industrial financial government ITtelecoms and healthcare applications.Device AddressingEach XP95 device responds to interrogation and command from central control equipment. It communicates to the panel information on status command bits type location and other information that allows an alarm to be raised even when the device is not itself being interrogated. Message error checking is also provided. The devices are compatible with Discovery systems and control equipment to aid maintenance extension and upgrade of existing systems.A unique patented XPERT card provides simple user friendly and accurate identification of detector location whereby a coded card inserted in the base is read by any detector once it is plugged in. All the electronic components are in the detector but the location information is held in the base. The address card simplifies and speeds up installation and commissioning. Addressing errors during maintenance and service are eliminated.Brand FeaturesAlarm flag for fast alarm reportingAlarm address for fast location of alarmXPERT 7 Card addressingElectronics-free baseEasy installationElegant designKey FeaturesXP95 Discovery and CoreProtocol compatibleResponds well to slowburning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressure

GBP 32.66
1