Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

311 results (0,15579 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo XP95 Heat Detector High Temperature 55000-401APO

Apollo XP95 Heat Detector High Temperature 55000-401APO

Apollo XP95 Heat Detector High Temperature 55000-401APOThe XP95 Heat Detector monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature. The XP95 range features two heat detectors standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55C. The high temperature detector classified as a CS device will report an alarm at 90C.OperationThe XP95 heat detectors have a low air flow resistance case made of self-extinguishing white polycarbonate. The devices monitor heat by using a single thermistor network which provides a voltage output proportional to the external air temperature. The standard heat detectors 55000-400 and 55000-420 respond to increasing air temperature in such a way that they are classified as an A2S device. Both devices will give 55 counts at 55C. A high temperature CS heat detector 55000-401 which can be installed in a typical ambient temperature of 55C is available. This device will give 55 counts at 90C.ApplicationThe choice of detector from the XP95 range follows the well-established principles of system design. That is the optimum detector type will depend on the type of fire risk and fire load and the type of environment in which the detector is sited. For general use smoke detectors are recommended since these give the highest level of protection. Smoke detectors from the XP95 range may be optical or multisensor types. It is generally accepted that ionisation types have a high sensitivity to flaming fires whereas optical detectors have high sensitivity to smouldering fires.Key FeaturesIdeal in environments that are dirty or smoky under natural conditionsWell suited for warehouses loading bays and car-parksUnaffected by wind or atmospheric pressure

GBP 32.66
1

Apollo Mounting Plate for 4 Prisms 100m 29600-529

Apollo Beam Detector Surface Mounting Plate for Prisms 29600-528

Apollo AlarmSense CS Heat Detector High Temperature 55000-193APO

Apollo Mounting Plate for 1 Prism 8-50m 29600-530

Apollo Universal Bracket for Beam Detector Heads and Prisms 29600-527

Apollo Singular Transparent Hinged Cover for Apollo Call Point 44251-189APO

Apollo Blank XPert Card for XPander Wireless Range -Red 29600-399

Apollo Blank XPert Card for XPander Wireless Range -Red 29600-399

Apollo Blank XPert Card for XPander Wireless Range RedSpare singular blank XPERT card in red for the XPander range. XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop.XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Brand Featuresmodern styling loop-powered interface operating on 868MHz wireless addresses seen by control panel as normal addresses radio base with wireless circuitry and battery compartment chamber designed to inhibit dirt penetration and thus reduce false alarms automatic drift compensation with DirtAlert warning algorithms for transient alarm rejection FasTest reduces time taken to test detectors remote test facility 3-5 years battery lifeProduct InformationAddress card supplied with all bases. Using a coding guide pips are removed to set the address of the inserted device.Key FeaturesSimplifies and speeds up installation and commissioningAddress remains the same no matter how often detectors are replacedUses patented proven technologyFlexibility to create any address

GBP 0.24
1

Apollo Blank XPert Card for XPander Wireless Range - White 29600-413

Apollo Wall Loop Powered VAD White Body White Flash 55000-744APO

Apollo Ceiling Loop Powered VAD White Body White Flash 55000-745APO

Apollo Ceiling Loop Powered VAD Red Body White Flash

Apollo Wall Loop Powered VAD Red Body White Flash 55000-741APO

Apollo Auto-Aligning Beam Detector Additional Head 8-50m 29650-070

Apollo Auto-Aligning Beam Detector 8-50m 29650-069

Apollo Auto-Aligning Beam Detector Extension Kit 100m 29600-526

Apollo XP95 Loop-Powered Beacon Red Beacon 55000-877APO

Apollo Discovery Manual Call Point with Isolator 58100-908APO

Apollo RW1000-760APO REACH Multi-Sensor Detector OpticalHeat Black Body