Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

139 results (0,13578 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m Radius

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m Radius

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m RadiusThe GS903N acoustic glassbreak sensor combines high false alarmimmunity and excellent detection by recognizing the exact frequencypattern generated by glass breaking. Instead of listening for a loudsound at one or two characteristic frequencies the GS903N listens at30 points across the glassbreak frequency spectrum. This not onlyenables it to discriminate common false alarm sources but alsoensures detection of even the quietest of breaks so it can be used withblinds or light curtains. The GS903N is recommended for perimeterloops and is designed to function in occupied areas. In 24-hour loopapplications where the detector is armed all day and all night thefalse alarm technology will be pushed to its limit. Some sounds canduplicate the points on the glassbreak pattern that the GS903 detects.Install the GS903N on a perimeter loop which is armed whenever thedoor and window contacts are armed. The GS903N false alarmimmunity is best in rooms with only moderate noise. For 24-houroccupied area protection use our Shock Detectors. The GS903N maynot consistently detect cracks in glass or bullets which break throughthe glass. Glassbreak detectors should always be backed up byinterior protection.Easy to install and testAvailable in both surface and flush mount versions GS913Ninstallation is quick and easy. There are no sensitivity adjustments toworry about and a new test feature means only one trip up the ladder.Simply activate the tester next to the GS903N and the unit goes intotest mode.A unique test assures end-users that the unit is powered and ready todetect. The sensor will blink twice but will not trip when a loud hardclap is made close to the unit.Pattern Recognition TechnologyThe GS903N detects in a full 360 coverage pattern with a 7.5 mrange from detector to glass. By listening at more than 30 frequencypoints the GS903N can tell the difference between common falsealarm sources and the noise of breaking glass.Key FeaturesNo sensitivity adjustment requiredDetects through blinds and light curtainsEnd user can test sensor operation with a clap of the hands GS903NGS913NRated for all types of glass including plate laminated tempered and wiredListens for the pattern of breaking glass across the frequency spectrumConsistent detection even of soft quiet glass breaks

GBP 74.56
1

Aritech WB1-HF Belden 9504 Cable - Low Smoke Halogen Free - 500 Metres Roll

Aritech AS619 Outdoor Siren

Aritech AS631V Outdoor Siren Inox VDS - Red Lens Beacon

Aritech ET010 Fibre-Glass Telescopic Pole - 4.5m

Aritech ATS1521N 2 Way Audio Smart Satellite

Aritech DC501 Mini Pull-Away Contact To Protect Free-Standing Items - 2m Cable - NC

Aritech 2000 Series Zone Monitor Unit - including IO-2Box IU2055NC

Aritech 2000 Series Zone Monitor Unit - including IO-2Box IU2055NC

Aritech 2000 Series Zone Monitor Unit - including IO-2Box IU2055NCThe IU2055NC is and addressable 2000 Series two-wire zone monitor designed to provide an interface between conventional fire detectors and an addressable 2000 series protocol fire alarm control panel. The IU2055NC enables the addressable panel to monitor the presence and operation of up to 30 conventional detectors in standard or up to 20 in intrinsically safe configurations.ApplicationThe IU2055NC allows for the upgrade and inclusion of an existing or new conventional fire zone into and addressable detection loop. It supervises the conventional zone circuit for open and short circuits and monitors it for alarm conditions. Any abnormal conditions are reported to the control panel and are indicated on the IU2055NC with a yellow LED. The unit supports alarm verification and CleanMe. It resets by cycling power to the zone circuit as directed by the fire panel.OperationThe IU2055NC is connected to the panel via a two-wire communication loop that provides power and carries control and input data. The module address is easily set with two rotary switches. The address setting is non-volatile and will not be lost in the event of a power failure.The 2000 series conventional zone monitor utilizes an advanced digital data communications protocol that ensures the integrity of the data communication with extensive error correction algorithms.Key DetailsMonitors up to 30 standard conventional or up to 20 intrinsically safe conventional detectorsZone supervised for open and short circuitsSupports alarm verification and CleanMe functionsLoop poweredEasy numeric addressingSupports standard and intrinsically safe applicationsCECPR certified to EN5418

GBP 55.72
1