Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

94 results (0,14927 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall Omnicare Type A Green Emergency Steward Telephone with Lock Door BVOCETL

Baldwin Boxall BV3ADIS VIGIL 3 Slave DC Line Monitoring IsolatorChangeover Mod

Baldwin Boxall Omnicare Type A Green Emergency Steward Telephone with Push Door BVOCET

Baldwin Boxall ECLIPSE 4 CASE BATT BOX BVECASE4BATT

Baldwin Boxall Omnicare Combined Red Fire Telephone and Green DRS Unit BVOCCGCP

Baldwin Boxall Omnicare Combined Red Locking Door CW Beacon BVOCCLB

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMP

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMP

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMPVIGIL2 voice alarm system power supplies employ switch mode techniques to improve efficiency and reduce unwanted heat dissipation and weight.Key FeaturesThe BVSMP has two individually protected outputs at 24V the BVSMPLT has one.Each BVSMP will drive either two BV225 two BV125D or two BV050Q.Each BVSMPLT will drive one BV225 one BV125D or one BV050Q.Provide independent power converters with current and overvoltage protection circuits.Continual monitoring of the charger and all DC outputs ensures reliability.Standby batteries are continually float charged by the unit. Ensuring that in the event of mains failure power is maintained.Built-in deep battery discharge cut off preventing total discharge that can destroy the standby batteries in the event of AC power failure for long periods.A protected output is provided to power a mixer or auxiliary circuits.In the event of a fault condition an internal relay releases providing a changeover contact. A fault will be indicated on the EVAS router.The constant voltage charger is set for the recommended float charge. Should the battery fall below this level the BVSMP will charge at a constant rate of three Amps progressively reducing once the battery has achieved its nominal float level.Outputs together with a volt-free fault changeover contact are provided by a nine-way crimp connector plug and socket.Several chargers may be paralleled when used for larger systems. Paralleled BVSMPs must be synchronised.

GBP 1243.78
1

Baldwin Boxall Omnicare Monitor Mounted Telephone Handset BVOCTSHSM

Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEP

Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEP

Baldwin Boxall BVCRM3 Rack Mount Kit for Mini Consoles 8-32 Way 7U

Baldwin Boxall Omnicare Comb Red PDoor CW Beacon BVOCCB

Baldwin Boxall Omnicare Repeater Unit BVOCRIF

Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050Q

Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050Q

Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050QThe Vigil2 BV050Q contains four independent 50 Watt Class D Power amplifiers each with one 500 mV balanced input and a 50 Watt 100V Line output. The front panel status indicators show Supply Healthy Overload Over Temperature and Output Level 10 and 100 max output level for each amplifier. The Active Indicator illuminates when the amplifier is not in Sleep Mode. CLASS D amplifiers are 80 efficient therefore reducing unwanted heat dissipation and power input requirements. Rated output power is obtainable using a 22V battery supply.The BV050Q has a Sleep mode automatically reducing the standby current requirement to typically 50mA per amplifier when operating on batteries. Channel gain may be individually set using the potentiometers on the board behind the front panel. The audio inputs to the amplifiers are presented on separate RJ45 connectors each connector providing the balanced audio input and a ground connection. The outputs are presented on 6-way plugscrew termination connectors providing 50V or 100V output. The 24V DC input is presented on a 2-way crimp connected plug and socket. The power output stage of the amplifier is protected against overload conditions i.e. short circuits or abnormal loads etc. Should the amplifier be subjected to an abnormal load the input to the power amplifier is attenuated to a safe level.The amplifiers output voltage is also sensed and should it exceed 100V the input signal will be attenuated ensuring safe operation without creating unnecessary distortion. Over temperature protection is provided using a sensor attached to the output stage heat sink. Should the temperature exceed 90 Degrees Celsius the input signal to will be attenuated to a safe level and the Overtemp LED will be illuminated. If the system is under surveillance it will cause the surveillance detector to indicate a fault condition due to the gain reduction. Up to three BV050Q Amplifier modules may be mounted in one BVMF equipment frame or more normally two amplifier modules and one switched mode power supply charger module.

GBP 1973.16
1

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAMThe BVLAM provides 8 zone 100V line relay switching loudspeaker zone selection from 1 amplifier.It incorporates impedance monitoring on all 8 loudspeaker lines when the zone is not selected. If the load increases impedance decreases the appropriate fault LED illuminates steady and if the load decreases impedance increases the fault LED will flash.The impedance changes for a fault to be detected is selected to either 20 or 40 using the mode DIL switch 8. If the impedance falls to approximately 50 of its original value the line is considered to be short circuit and will not be selected to the amplifier.All 8 zone select inputs will access when it is between 2 to 6.5V. An open circuit access input above 15V will be indicated by the appropriate fault LED flashing and a short circuit access input below 2V by the fault LED illuminating steady.Under all fault conditions the OK LED will extinguish and the common fault relay volt-free contacts to change state.Key FeaturesRack-mountable unit 1U high. Two units can be mounted across one rack shelf.Provides eight loudspeaker zone selection from one amplifier.On receipt of a signal from an input ie zone selecting microphone the BVLAM triggers the amplifier to output to the selected zone.An internal relay enables zone switching.The BVLAM provides constant impedance monitoring on each of the eight loudspeaker circuits when not selected.LEDs are used to indicate a drop or increase in impedance - set at either 20 or 40 by DIL switches.Note due to detection accuracy BVLAM is only suitable for BS5839-8 voice alarm systems with less than five speakers per circuit.Access faults on any of the zones from the microphone are indicated by LEDs on the BVLAM.Additional LED indicators are provided to show system healthy and supply healthy.The Baldwin Boxall Impedance Monitor BVLAM provides a combination of zones relay switches from one amplifier. It changes if a fault is detected.

GBP 880.90
1

Baldwin Boxall Consisting BVOC64S.BY90 amp BVOBATT2 BVOC64S

Baldwin Boxall Consisting BVOC64S.BY90 amp BVOBATT2 BVOC64S

Baldwin Boxall Consisting BVOC64S.BY90 BVOBATT2 BVOC64SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 5360.64
1

Baldwin Boxall Consisting BVOC80S.BY90 amp BVOBATT2 BVOC80S

Baldwin Boxall Consisting BVOC80S.BY90 amp BVOBATT2 BVOC80S

Baldwin Boxall Consisting BVOC80S.BY90 BVOBATT2 BVOC80SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 6598.97
1

Baldwin Boxall Consisting BVOC16MS. ampBY24 BVOC16MS

Baldwin Boxall Consisting BVOC16MS. ampBY24 BVOC16MS

Baldwin Boxall Consisting BVOC16MS. BY24 BVOC16MSOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 2110.15
1

Baldwin Boxall Consisting BVOC32MS. ampBY24 BVOC32MS

Baldwin Boxall Consisting BVOC32MS. ampBY24 BVOC32MS

Baldwin Boxall Consisting BVOC32MS. BY24 BVOC32MSOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 2874.91
1