Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

220 results (0,15044 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall Amplifier Line Monitor with Automatic Amplifier Changeover BVRDACO

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4The BVRD2M4 is a four-zone voice alarm router with the same great features as the BVRD2M designed for smaller installations and networked decentralised systems.Key FeaturesDSP control.Possible to monitor up to four dual AB circuits.Four electronically balanced inputs. Input one is configurable with all call processor bypass and is normally used for the fire microphone in voice alarm systems. All inputs have both independent priority and level settings allowing for dual mode emergency and normal page.Up to fifteen priority levels are available. If two concurrent routes are set at the same priority they will be treated on a first come first served basis. Priorities are changeable.Three band parametric plus bass and treble equalisation on all inputs with limitercompressor enhancing the intelligibility of the system.Four audio electronically balanced 0dBM outputs with ten band parametric equalisation and audio delay of up to one second.Fully monitored surveillance at either 30Hz or 20kHz faults are recorded in the history log.Built-in real-time clock enables detailed logging and reporting including detected faults. Indicates time date month and year. Also used for night time volume reduction timed message trigger and to control external inputs. The history log can be accessed via the USB2 port on the front panel.Six flash stored 57 second messages with independent level surveillance and timing. Settings and messages are changeable password protected via the USB2 port.Nine selectable chimes pre-announcement tones of up to eight seconds in length.Up to 126 EVAS routers can be networked using fibre or copper to produce a truly sophisticated VA network.Message synchronisation even on a decentralised system.Ambient noise sensing using optional ambient noise sensing microphones.Amplifier changeover for up to three zones using optional relay board product code BVRD2M4ACO.Two RS485 ports for networking microphones etc.Zone grouping and barring on BVRD voice alarm controller.

GBP 1813.49
1

Baldwin Boxall Eight Zone Emergency Fire Microphone BFM408

Baldwin Boxall Single Zone Emergency Fire Microphone BFM401

Baldwin Boxall Four Zone Emergency Fire Microphone BFM404

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2M

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2M

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2MThe VIGIL EVAS BVRD2M DSP-controlled router is well-established and has been installed in many prestigious sites Worldwide.VIGIL EVAS routers are feature rich and in common with all Baldwin Boxall products are built to a very high standard. A voice alarm system MUST work when needed during an emergency such as a fire. Baldwin Boxalls voice alarm systems are renowned for their reliability and can be installed with confidence.There are two routers in the EVAS range the BVRD2M and the BVRD2M4 as well as slave router options. The modular style of the VIGIL2 voice alarm system offers great choice and flexibility. It is as suitable for small systems as it is for very large networked systems.Key FeaturesDSP control.Eight electronically balanced inputs. Inputs one and two are configurable with all call processor bypass and are normally reserved for fire microphones. All inputs have both independent priority and level settings.Up to fifteen priority levels are available. If two concurrent routes are set at the same priority they will be treated on a first come first served basis. Priorities are changeable.Three band parametric plus bass and treble equalisation on all inputs with limitercompressor enhancing the intelligibility of the system.All call failsafe emergency message generator twenty second EPROM.Seven electronically balanced audio outputs with ten band parametric equalisation and audio delay of up to one second.Fully monitored surveillance at either 30Hz or 20kHz faults are recorded in the history log. All inputs outputs and DSP messages can be aurally monitored through a loudspeaker on the front panel.Built-in real-time clock enables detailed logging and reporting including detected faults. Indicates time date month and year. Also used for night time volume reduction timed message trigger and to control external inputs. The history log can be accessed via the USB2 port on the front panel.Six flash stored 57 second messages with independent level surveillance and timing. For longer non-critical messages up to three can be combined. Settings and messages are changeable password protected via the USB2 port.Nine selectable chimes pre-announcement tones of up to eight seconds in length.Expandable with BVRD2S slave router and CANBUS modules.Up to 126 EVAS routers can be networked using fibre or copper to produce a truly sophisticated digital VA network.Message synchronisation even on a decentralised system.Ambient noise sensing.Amplifier changeover one in ten.Two RS485 ports for networking microphones etc.Zone grouping and barring on BVRD voice alarm controller.

GBP 4187.64
1

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCFThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCF red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFS.Push catch door slot lock version available BVOCFL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 540.70
1

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFL red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFSL.Slot lock door push catch version available BVOCF.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 576.98
1

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFSL fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCFL.Slot lock door push catch version available BVOCFS.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 799.25
1

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFS

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFS

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFSThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFS fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCF.Push catch door slot lock version available BVOCFSL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 762.05
1

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCCThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.

GBP 876.36
1

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCLThe combined unit for the Omnicare LOOP-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.

GBP 886.33
1

Baldwin Boxall Large Format Touch Screen Monitor cw Software for Customisation BVRDTSMMON

Baldwin Boxall OmniCarePLUS Control Hub with Touch Screen PC and Monitor Mounted Phone BVOCTSPCM

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSPThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 1041.47
1

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSLThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 1071.41
1

Baldwin Boxall Call Point Red Cord Wall Mounted Stainless Steel DTASCPW

Baldwin Boxall BVECASE5 Eclipse5 comes with BVMBC amp BV3AOM8 amp BVECASE5AT amp Fan Tray

Baldwin Boxall BVECASE5 Eclipse5 comes with BVMBC amp BV3AOM8 amp BVECASE5AT amp Fan Tray

Baldwin Boxall BVECASE5 Eclipse5 comes with BVMBC BV3AOM8 BVECASE5AT Fan TrayThe VIGIL Eclipse5 is a powerful standalone voice evacuation public address system. A complete fully monitored system which takes less floor space and is ideal for fitting into building risers or places where space is restricted. Modular and fully networkable the VIGIL Eclipse5 provides the solution for any site.The unit houses the required number of input and output modules one BVMBC battery charger Network Interface modules if required suitable batteries and a choice of up to four amplifier mainframes.Key FeaturesA fully integrated voice evacuation system the Eclipse5 takes up minimal floor space and is secured by bolting to a wall or suitable solid uprightEach Eclipse5 is capable of up to 16 zonesConnect up to eight inputs to each Eclipse5Due to its upright design the Eclipse5 is ideal for fitting within the risers of towers and other similar style buildings or small spacesThe system will continue to function in the event of a mains power failure 24 hours quiescent and 30 minutes full use. For some systems a bolt on battery enclosure is required to house additional batteriesModular system with a choice of amplification using the VIGIL3 Ethernet routeing backbone and VIGIL3 transformerless amplifiersMessage synchronisation - even on decentralised systems - with the ability to store up to 254 monitored messagesFully monitored via selectable surveillance using either AC or DC line monitoring methods.The Eclipse5 accepts VIGIL3 two or four way input modulesElectronically balanced 0dBM with up to 24 band parametric equalisation and audio delay of up to one secondOptions include ambient noise sensing facility using noise sensing microphones and an all call fire microphone which can be fitted on the front panelNetworking is via copper multi-mode fibre single mode fibre or any combination of these with 64 simultaneous audio channels.It is possible to network up to 100 Eclipse5 units together offering a total system size of 400 inputs and 800 outputsEclipse5 supports our paging microphone fire microphones and touchscreen control optionsDimensions mm 1125 H x 500 W x 200 D

GBP 4524.20
1

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMP

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMP

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMPVIGIL2 voice alarm system power supplies employ switch mode techniques to improve efficiency and reduce unwanted heat dissipation and weight.Key FeaturesThe BVSMP has two individually protected outputs at 24V the BVSMPLT has one.Each BVSMP will drive either two BV225 two BV125D or two BV050Q.Each BVSMPLT will drive one BV225 one BV125D or one BV050Q.Provide independent power converters with current and overvoltage protection circuits.Continual monitoring of the charger and all DC outputs ensures reliability.Standby batteries are continually float charged by the unit. Ensuring that in the event of mains failure power is maintained.Built-in deep battery discharge cut off preventing total discharge that can destroy the standby batteries in the event of AC power failure for long periods.A protected output is provided to power a mixer or auxiliary circuits.In the event of a fault condition an internal relay releases providing a changeover contact. A fault will be indicated on the EVAS router.The constant voltage charger is set for the recommended float charge. Should the battery fall below this level the BVSMP will charge at a constant rate of three Amps progressively reducing once the battery has achieved its nominal float level.Outputs together with a volt-free fault changeover contact are provided by a nine-way crimp connector plug and socket.Several chargers may be paralleled when used for larger systems. Paralleled BVSMPs must be synchronised.

GBP 1243.78
1

Baldwin Boxall CARE2 Type A Red Fire Telephone with Push Door C2FTRP