Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

68 results (0,14902 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec CFP Network Driver Card CFP761

C-Tec CFP760 8 Zone Repeater Panel

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels.Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 315.26
1

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 433.36
1

C-Tec FPROSG Calibrated Audio Signal Generator

C-Tec ZFP240CA ZFP 2 Loop Panel 5A 40LED CAST

C-Tec QT602KSSS Quantec Stainless Steel Call Point - Key Reset with Sounder

C-Tec ZFP140CA ZFP 1 Loop Panel 5A 40LED CAST

C-Tec ZFP120CA ZFP 1 Loop Panel 5A 20LED CAST

C-Tec ZFP1CA ZFP 1 Loop Panel 5A CAST

C-Tec ZFP2CA ZFP 2 Loop Panel 5A Cast

C-Tec ZFP220CA ZFP 2 Loop 5A 20LED CAST

C-Tec ZFP140PCA ZFP 1 Loop Panel 5A 40LED CAST cw Printer

C-Tec ZFP240PCA ZFP 2 Loop Panel 5A 40LED CAST cw Printer

C-Tec BF433CEASW Wall Sounder VID - Self Testing - White

C-Tec ZFP220PCA ZFP 2 Loop Panel 5A 20LED CAST cw Printer

C-Tec ZFP120PCA ZFP 1 Loop Panel 5A 20LED CAST cw Printer

C-Tec NC805MD Portable Movement Detector

C-Tec QT707S Quantec Surveyor Data Management Software

C-Tec 16 Line SigTEL Master Controller cw handset. Max 2 x 7Ah batteries ECU-16

C-Tec 16 Line SigTEL Master Controller cw handset. Max 2 x 7Ah batteries ECU-16

C-Tec 16 Line SigTEL Master Controller cw handset. Max 2 x 7Ah batteries ECU-16Designed foruse with our popular SigTEL system the ECU-16 features a new-look high-performance handset to allow operators tocommunicate with up to 16 disabled refuge or firetelephone systems.The controllers powerful networking capabilities also allow up to 14ECU-16 mastercontrollers to be interlinked to create systems of up to224 lines. A separate ECU-224desk control unit can also be connectedtoallow communication with up to 224outstations from a single point.Compatible with C-TECs entire range of Type A Fire Telephone andType B Disabled Refugeoutstations and remote fire telephonehandsets the controller can be easilyinterfaced to NC951 accessibletoilet alarms PDA hearing loop systems strobesCCTV activation relaysand more.Key FeaturesA new 16-line Master Controller for use with our SigTEL disabled refuge fire telephone and stadium marshallingsystem.Allows operators to communicate with up to four disabled refuge or fire telephone outstations.Includes an attractive semi-recessed handset.Improved SigTEL networking capability allow systems of up to 224 lines to be created with optionaladditional desk unit control.Backlit LCD and unique auto-learn facility allows fast system set up.Can be semi-flush mounted using an AFP385 bezel.Operation can be maintained for 24 hours standby and 3 hours in use using 2 x 12V 7 Ahr batteries.Easily interfaced to NC951 accessible toilet alarms PDA range hearingloop systems strobes CCTV activation relays etc.

GBP 1906.25
1

C-Tec PDA11DD 1000m2 Free-Standing Phased-Shifting Hearing Loop Amplifier