Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

30 results (0,14494 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec FF388-2 FP8 8 Zone Fire Panel

C-Tec SAP501EX SAP 1 Loop 16 Zone Addressable Sprinkler Monitoring Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master PanelNC812KE NC822KE and NC832KE indicator panels are fully compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on the devices wired to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. An optional Mute button is also provided to allow the user to silence standard calls.Standard Calls when triggered by a calling device the indicator panels internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Indicator Panels Mute Button if fitted silences the Panels internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Emergency Calls when triggered by a calling device theIndicator Panels internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted at the Panel. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesFully compatible with C-TECs entire range of 800 Series Call System componentsCapable of indicating standard constant tone and emergency intermittent tone calls10 20 or 30 zonal alarm LEDs dependent on model purchased see below for parts listingOptional mute button2 volt-free relay contactsSurface mountingConnections for optional Repeater panels and sounders to increase call indication levels

GBP 466.69
1

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 633.78
1

C-Tec XFP501EH XFP Addressable Single Loop 16 Zone Panel - Hochiki Protocol

C-Tec XFP501EH XFP Addressable Single Loop 16 Zone Panel - Hochiki Protocol

C-Tec XFP501EH XFP Addressable Single Loop 16 Zone Panel - Hochiki ProtocolC-TECs XFP single loop 16 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in an attractiveflush or surface mountable plastic enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling entry-level addressable fire panels. Packed full of engineering features-some of which are not available on more expensive alternativessee feature list below-the XFP501EX is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 467.00
1

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP two loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 796.78
1

C-Tec XFP501EX XFP Addressable Single Loop 16 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501EX XFP Addressable Single Loop 16 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501EX XFP Addressable Single Loop 16 Zone Panel - XP95 Discovery ProtocolC-TECs XFP single loop 16 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in an attractiveflush or surface mountable plastic enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling entry-level addressable fire panels. Packed full of engineering features-some of which are not available on more expensive alternativessee feature list below-the XFP501EX is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 467.00
1

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 633.78
1

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP two loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 796.78
1

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteriesC-TECs tried and trusted XFP two loop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 13.With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful two loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Key features include 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 701.32
1

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah BatteriesC-TECs tried and trusted XFP oneloop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful one loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 557.02
1

C-Tec BF3593S Stainless Steel Glazed Enclosure

C-Tec PDA5DD 200m2 Free Standing Phase-Array Hearing Loop Amplifier

C-Tec EAP28CAEA EAP 2L 8Z 5A CAST C-TEC EACIE Complete With Cabinet

C-Tec PDA7DW 500m2 Wall-Mounting Phased-Shifting Hearing Loop Amplifier

C-Tec PDA5DW 200m2 Wall-Mounting Phased-Shifting Hearing Loop Amplifier

C-Tec PDA11DW 1000m2 Wall-Mounting Phased-Shifting Hearing Loop Amplifier

C-Tec PDA11DD 1000m2 Free-Standing Phased-Shifting Hearing Loop Amplifier

C-Tec PDA7DD 500m2 Free-Standing Phased-Shifting Hearing Loop Amplifier

C-Tec PDA11SD 1000m2 Free-Standing Hearing Loop Amplifier 11A