Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

24 results (0,14107 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec CA740 Cast 4w Conventional Zone Convertor - No PSU Included

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 130.25
1

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 148.46
1

C-Tec NC943B Conventional Single Zone Call Controller

C-Tec NC941SS Conventional Stainless Steel Single Zone Call Controller with PSU amp Reset Button

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network.

GBP 114.65
1

C-Tec Output Expansion Relay Board EP212

C-Tec NC951 Conventional Accessible Toilet Alarm Kit to BS8300

C-Tec NC951 Conventional Accessible Toilet Alarm Kit to BS8300

C-Tec NC951 Conventional Accessible Toilet Alarm Kit to BS8300The Kit includes everything required for BS8300 clause compliant emergency assistance alarm. Attractively designed and easy to install the NC951 allows a distressed person to raise an alarm in the event of an emergency.To operate the user pulls the cord of a ceiling pull cord to activate a light and sounder outside the WC and on the systems call controller. A new Call Accept facility allows staff to send an intermittent call acknowledgement signal to the WC to confirm help is on the way.The NC951 can be wired in to 4 core stranded security cable but can also be used as a single zone emergency assistance alarm in areas such as changing rooms solariums interview rooms reception areas and more.Kit Contains1 x NC943B 12V 140mA Call Controller cw standby battery and relay1 x NC807C Ceiling Pull Cord1 x NC806CS Overdoor Light cw Sounder1 x NC809DBBT Accessible Toilet Reset Point cw Sounder1 x Accessible WC StickerKey FeaturesThe UKs market-leading Disabled Persons Toilet Alarm kit now with a combined ceiling and wall mountable pull cord unitIncludes everything required for a BS8300 compliant emergency assistance alarmEasy to install simple to useAllows a distressed person to raise an alarm in an emergency. To operate the user pulls the cord of the ceilingwall pull to activate a light and sounder outside the WC and on the systems Call ControllerThe systems Call Accept function allows staff to send an intermittent call acknowledgment signal to the WC to confirm help is on the wayIncludes an NC943B 12V 140mA Call Controller cw standby battery relay NC807C CeilingWall Pull NC806CS Overdoor Light cw Sounder NC809DBBT Accessible Toilet Reset Point cw Sounder NC949 Accessible WC StickerCan be wired in 4 core stranded security cableCan also be used as a single zone assistance alarm in changing rooms solariums interview rooms reception areas more

GBP 116.27
1

C-Tec APXMM Mini-Mixer Plate

C-Tec APXMM Mini-Mixer Plate

C-Tec APXMM Mini-Mixer PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesCombines the functions of anAPXM microphone Outreach plate and an APL dual phono Outreachplate in one double gang device.Accepts balanced or unbalanced microphones with standard 3 pin XLR connectors AND dual phono line level inputs.Gives a more attractive appearance than separate side-by-side single gang Outreach Plates.Counts as one of the total of ten plates permitted aspart of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK doublegang back box.

GBP 96.35
1