Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

15 results (0,13784 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cooper Menvier 400034FIRE-0074 BACNET LON Interface

Cooper CPT341 Conventional Photo-Thermal Detector MPT951 EFXN632

Cooper CMT390 Conventional Fixed Heat Detector 92 Degrees EFXN526 MHT890

Cooper CFR330 Conventional Rate of Rise Heat Detector EFXN525 MFR830

Cooper CPD321 Conventional Optical Smoke Detector EFXN533 MPD821

Cooper EFXN533 Conventional Optical Smoke Detector CPD321 MPD821

Cooper CAP320 Intelligent Addressable Optical Smoke Sensor MAP820 FXN723 400002FIRE-0002X

Cooper Menvier 400032FIRE-0072 LON to TCP-IP Convertor

Cooper Menvier 400033FIRE-0073 LON Network Booster

Cooper CAPT340 Intelligent Addressable Photo Thermal Sensor MAOH850 FNX722 400004FIRE-0004X

Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor MAH830 FXN725 400003FIRE-0003X

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode HeatSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensation

GBP 34.94
1

Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor

Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor

Cooper Menvier 400004FIRE-0004X Addressable Photo-ThermalSensor This range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice

GBP 42.90
1

Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor

Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor

Cooper Menvier 400002FIRE-0002X Addressable Optical SmokeSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice

GBP 34.98
1

Cooper NCDR Dual Redundant Network Card

Cooper NCDR Dual Redundant Network Card

Cooper NCDR Dual Redundant Network CardThe NCDR is the heart beat of the Cooper true Pier-to Pier fault tolerant network. It allows information from any Cooper input and output device to be passed over the network and display on any Cooper Addressable Fire panels or remote display such the Sire monitor or the Cooper Graphic Package. Information such as Fire General Alarm Pre-alarm Faults Disablement and status information from any panel is accessible on the Cooper Pier to Pier network thus allowing site wide cause and effect functionality.Simply by adding and connecting the NCDR network card allows any Cooper addressable Fire Alarm control Panel to be networked. All other panels on the network will be instantly aware of a panel as soon as it is given valid network address thus allowing additional panels to be added at any time with a minimum amount of re-programming. The NCDR dual channel serial gateway consists of two channels each using a FT3150 Smart transceiver and FT-X1 communication transformer.Each Neuron supports a serial 232 interface allowing the Master Neuron to communicate with the host equipment and also to send messages to and receive messages from the Slave Neuron. This allows nodes to communicate using 2 separate networks simultaneously thereby providing continuous communication in the event of open or short circuit faults on either network. Software prevents the duplication of messages. The network can be mounted inside the cooper addressable fire panels.

GBP 318.67
1