Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

12 results (0,13879 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

FFE Fireray 5000-103 Fireray 5000 System ULFM

FFE Fireray 5000-103 Fireray 5000 System ULFM

FFE Fireray 5000-103 Fireray 5000 System ULFMThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.25 ft. to 330 ft. 8m to 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1191.90
1

FFE Fireray 5000-104 Fireray 5000 System Long Range ULFM

FFE Fireray 5000-104 Fireray 5000 System Long Range ULFM

FFE Fireray 5000-104 Fireray 5000 System Long Range ULFMThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1313.70
1

FFE Fireray 5000-003 Fireray 5000 Controller ULFM

FFE Fireray 5000-003 Fireray 5000 Controller ULFM

FFE Fireray 5000-003 Fireray 5000 Controller ULFMA spare Fireray 5000 controller.The Fireray 5000 Spare System Controller supports up to two Fireray 5000 beam detector heads.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesSpare System Controller low levelLogs the 50 most recent eventsProgrammable sensitivity and fire thresholds20mm cable gland knock-outs on system controller2-wire interface from system controller to detectorWorking optical path for detector alignmentIdeally suited protecting large areas where use of traditional detectors would be difficultcostly to install5 year warranty

GBP 887.40
1

FFE Fireray 5000-001 Fireray 5000 Controller EN

FFE Fireray 5000-001 Fireray 5000 Controller EN

FFE Fireray 5000-001 Fireray 5000 Controller ENA spare Fireray 5000 controller.The Fireray 5000 Spare System Controller supports up to two Fireray 5000 beam detector heads.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesSpare System Controller low levelLogs the 50 most recent eventsProgrammable sensitivity and fire thresholds20mm cable gland knock-outs on system controller2-wire interface from system controller to detectorWorking optical path for detector alignmentIdeally suited protecting large areas where use of traditional detectors would be difficultcostly to install5 year warranty

GBP 887.40
1

FFE Fireray 5000-112 Fireray 5000 System NF

FFE Fireray 5000-112 Fireray 5000 System NF

FFE Fireray 5000-112 Fireray 5000 System NFThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.25 ft. to 330 ft. 8m to 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1191.90
1

FFE Fireray 5000-113 Fireray 5000 System Long Range NF

FFE Fireray 5000-113 Fireray 5000 System Long Range NF

FFE Fireray 5000-113 Fireray 5000 System Long Range NFThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1313.70
1

FFE Fireray 5000-046 Fireray 5000 Detector - Long Range ULFM

FFE Fireray 5000-046 Fireray 5000 Detector - Long Range ULFM

FFE Fireray 5000-046 Fireray 5000 Detector - Long Range ULFMA spare Fireray 5000 detector - long range.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1078.80
1

FFE Fireray 3000-103 Fireray 3000 System UL

FFE Fireray 3000-103 Fireray 3000 System UL

FFE 3000-103 Fireray 3000 System ULThe Fireray 3000 End to End Infra-red Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings.The Fireray 3000 is ideal for applications where line of sight for the IR infra-red detection path is narrow and where the building structure use reflective surfaces.The projected beam type smoke detector shall be listed to U.L. 268 and shall consist of up to two transmitters two receivers and a single low level remote control unit. The detector shall operate between a range of 16.5 ft. to 393 ft. 5m to 120m. The temperature range of the system shall be -4F to 131F -20C to 55C. The receiver shall include an integral built-in laser pointer to assist in optimum alignment.The beam detector shall feature automatic gain control which will compensate for gradual signal deterioration from dirt accumulation on the lenses. The receiver heads shall incorporate a Wide Field of View to ensure the unit is always receiving maximum signal available. The system shall include a low level remote display and control unit with LCD read-out for set-up reporting and testing of up to 2 separate sets of heads. The system shall be capable of sending separate Trouble and Alarm signals for each of the sets of heads. The system shall be capable of programming alarm thresholds of 25 to 60 in 1 increments. The system shall be capable of programming delay to fault and delay to alarm from 2 seconds to 30 seconds in 1 second increments.Key FeaturesSeparate Transmitter and Receiver HeadsLateral Spacing per NFPA 72 is 60 feetIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Channel capabilitySeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationKnockouts for ease of installation and wiring

GBP 1392.00
1

FFE Fireray 5000-048 Fireray 5000 Detector NF

FFE Fireray 5000-048 Fireray 5000 Detector NF

FFE Fireray 5000-048 Fireray 5000 Detector NFA spare Fireray 5000 detector NF.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.2 ft to 328 ft 8 m to 100 mLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 948.30
1

FFE Fireray 5000-031 Fireray 5000 Detector ULFM

FFE Fireray 5000-031 Fireray 5000 Detector ULFM

FFE Fireray 5000-031 Fireray 5000 Detector ULFMA spare Fireray 5000 detector.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.2 ft to 328 ft 8 m to 100 mLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 948.30
1

Fireray 3000 Exd Explosion Proof Detector 3000-026

Fireray 3000 Exd Explosion Proof Infrared Beam Smoke Detector 3000-115