Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

43 results (0,22067 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder DriverThe MTL5525 Isolating Sounder Driver enables an intrinsically safe sounder located in the hazardous area to be controlled from the safe area.The barrier is designed as a CE marked replacement for the existing MTL3021 barrier. It has one channel and is suitable for connecting loads in Zone 0 IIC T4-T6 hazardous areas if suitably certified. It enables an onoff device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area. It can drive loads such as solenoids alarms LEDs and other low power devices that are certified as intrinsically safe or are classified as nonenergy storing simple apparatus.MTL5500 Series isolating IS interface units offer a compact and easy-to-use means for communicating safely with process measuring indicating actuating and local control equipment in hazardous areas. The range of models handle analogue and binary signals in both directions amplifying or otherwise conditioning them as required and at the same time providing certified explosion protection for equipment and wiring in all zones and all explosive atmospheres. The range has been designed for reliability. It builds on the proven success of the MTL2000 3000 4000 and 5000 Series to bring the benefits of new developments in galvanic isolation without compromising the reliability of the designs from which it has evolved. It is designed from the outset to meet all relevant European Directives. Uniform appearance and connectability of the units and a comprehensive range of accessories and enclosures make planning a pleasure for the user.Key FeaturesInput Type VoltageOutput Type VoltageSignal Conditioner Type IsolationInput Range 1.4 - 4.5 V dcOutput Range 7.8 - 24 VMounting Type DIN RailMinimum Operating Temperature -20CMaximum Operating Temperature 60CNumber of Channels 1Module Type SolenoidAlarm DriverTermination CableOperating Temperature Range -20 - 60 CSeries MTL5000

GBP 213.74
1

Fireclass 517.001.247FC DX170 Enclosure with 170mm DIN Rail

Fireclass 517.001.248FC DX070 Enclosure with 70mm DIN Rail

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF ModuleThe MPM800 is used to provide various expansion capabilities via the remote bus RBUS. The MPM800 is provided as a standalone module but is also incorporated into the circuitry of the OCM800 operator control module to drive the LCD display LEDs key switch and keys on the OCM800 and the operator display module.The OCM800 and MPM800 have an XBUS which can be used to drive up to 80 IO. The MPM800 also has a printer interface for connecting to a serial or parallel printer.An additional printer driver kit is required to allow the MPM800 to drive a printer - a serial isolation module should be used to eliminate earth fault indications caused by some mains connected printers.Up to 15 x MPM modules can be connected to each panel of which 8 can be in the form of OCM800 including the main OCM800 user interface. One OCM800 can also be in the form of an emulated user interface on a remote PC connected via the network or dial up modem.The following IO and LED annunciator modules can be saved from an MPM800Up to 5 x IOB 800 8 in8 out expansion boardUp to 5 x XIOM 800 16 way universal IO boardOne Mimic Panel 80-way LED mimic driver PCBOne 80-way ANN 880 LED mimicOne 40-way ANN 840 LED mimic using red yellow LEDsTwo 20-way COM 820 LED statuscommand modulesThe MPM800 is mounted by plugging directly onto the back of those items markedKey FeaturesFeatures an XBUS whichcan be used to drive up to 80 IOPrinter interface for connecting to a serial or parallel printerDirect Interface to Zonal Displays and other ModulesInterfaces to FIM Board

GBP 230.37
1

Fireclass 508.070.100FC FCG Dongle amp Software CD

Fireclass 516.016.159FC ProReact EN Analogue Nylon Cable 500m

Fireclass FC604S Four Loop Addressable Fire Panel 557.200.651FC

Fireclass FC604S Four Loop Addressable Fire Panel 557.200.651FC

Fireclass FC604S Four Loop Addressable Fire PanelThe FC604S is a four loop FireClass networkable panel with a shallow housing. This panel can have four standard-power loops or two high-power loops with each panel having a maximum of 500 addresses. It features a colour LCD display with 32 zonal LEDs and has a maximum capacity of 17 Ah batteries.The FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments therefore the system is highly resilient to external factors such as electrical noise including interference from electrical signals from other devices and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.It also brings a new FireClass Colour User Interface FC-CUI making it the perfect choice for small to mid-size systems up to 500 devices while keeping cost efficiency in mind. The panel has been specifically engineered to offer increased loop capacity and the option to share loops giving even more flexibility in the systems design and a reduction in installation costs.The new concept of high-power loops makes it easy to migrate from legacy FireClass range to new FC600 platform. The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users.The FC600 range offers integrated fire detection solutions for many mid-size applications including hotels commercial offices healthcare environments industrial and manufacturing facilities.Key FeaturesColour LCD display with 32 zonal LEDsSimple to operate user interfaceFlexible loop configurations with up to 1A current to increase use of loop power and address capacityComprehensive point management10000 event logEditable quiescent display textExtensive special cause and effect programmingManual and automatic walk testAutomatic battery testDetector service functionsFront panel controls enabling text and configuration changesNetworkableUp to seven fully functional repeatersOptional easy-mount plateOptional expansion kit for mounting additional cards

GBP 981.83
1

Fireclass FC602S Two Loop Addressable Fire Panel 557.200.650FC

Fireclass FC602S Two Loop Addressable Fire Panel 557.200.650FC

Fireclass FC602S Two Loop Addressable Fire PanelThe FC602S is a compact two-loop FireClass networkable panel with a shallow housing. It can have two standard-power loops or one high-power loop with each panel having a maximum of 250 addresses. The panel features a colour LCD display with 32 zonal LEDs and has a maximum capacity of 17Ah batteries.The FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments therefore the system is highly resilient to external factors such as electrical noise including interference from electrical signals from other devices and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.It also brings a new FireClass Colour User Interface FC-CUI making it the perfect choice for small to mid-size systems up to 500 devices while keeping cost efficiency in mind. The panel has been specifically engineered to offer increased loop capacity and the option to share loops giving even more flexibility in the systems design and a reduction in installation costs. The new concept of high-power loops makes it easy to migrate from legacy FireClass range to new FC600 platform.The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users. The FC600 range offers integrated fire detection solutions for many mid-size applications including hotels commercial offices healthcare environments industrial and manufacturing facilities.Key FeaturesColour LCD display with 32 zonal LEDsSimple to operate user interfaceFlexible loop configurations with up to 1A current to increase use of loop power and address capacityComprehensive point management10000 event logEditable quiescent display textExtensive special cause and effect programmingManual and automatic walk testAutomatic battery testDetector service functionsFront panel controls enabling text and configuration changesNetworkableUp to seven fully functional repeatersOptional easy-mount plateOptional expansion kit for mounting additional cards

GBP 765.65
1

Fireclass 557.200.650FC FC602S Two Loop Addressable Fire Panel

Fireclass 557.200.650FC FC602S Two Loop Addressable Fire Panel

Fireclass 557.200.650FC FC602S Two Loop Addressable Fire PanelThe FC602S is a compact two-loop FireClass networkable panel with a shallow housing. It can have two standard-power loops or one high-power loop with each panel having a maximum of 250 addresses. The panel features a colour LCD display with 32 zonal LEDs and has a maximum capacity of 17Ah batteries.The FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments therefore the system is highly resilient to external factors such as electrical noise including interference from electrical signals from other devices and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.It also brings a new FireClass Colour User Interface FC-CUI making it the perfect choice for small to mid-size systems up to 500 devices while keeping cost efficiency in mind. The panel has been specifically engineered to offer increased loop capacity and the option to share loops giving even more flexibility in the systems design and a reduction in installation costs. The new concept of high-power loops makes it easy to migrate from legacy FireClass range to new FC600 platform.The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users. The FC600 range offers integrated fire detection solutions for many mid-size applications including hotels commercial offices healthcare environments industrial and manufacturing facilities.Key FeaturesColour LCD display with 32 zonal LEDsSimple to operate user interfaceFlexible loop configurations with up to 1A current to increase use of loop power and address capacityComprehensive point management10000 event logEditable quiescent display textExtensive special cause and effect programmingManual and automatic walk testAutomatic battery testDetector service functionsFront panel controls enabling text and configuration changesNetworkableUp to seven fully functional repeatersOptional easy-mount plateOptional expansion kit for mounting additional cards

GBP 992.05
1

Fireclass 557.200.651FC FC604S Four Loop Addressable Fire Panel

Fireclass 557.200.651FC FC604S Four Loop Addressable Fire Panel

Fireclass 557.200.651FC FC604S Four Loop Addressable Fire PanelThe FC604S is a four loop FireClass networkable panel with a shallow housing. This panel can have four standard-power loops or two high-power loops with each panel having a maximum of 500 addresses. It features a colour LCD display with 32 zonal LEDs and has a maximum capacity of 17 Ah batteries.The FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments therefore the system is highly resilient to external factors such as electrical noise including interference from electrical signals from other devices and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.It also brings a new FireClass Colour User Interface FC-CUI making it the perfect choice for small to mid-size systems up to 500 devices while keeping cost efficiency in mind. The panel has been specifically engineered to offer increased loop capacity and the option to share loops giving even more flexibility in the systems design and a reduction in installation costs.The new concept of high-power loops makes it easy to migrate from legacy FireClass range to new FC600 platform. The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users.The FC600 range offers integrated fire detection solutions for many mid-size applications including hotels commercial offices healthcare environments industrial and manufacturing facilities.Key FeaturesColour LCD display with 32 zonal LEDsSimple to operate user interfaceFlexible loop configurations with up to 1A current to increase use of loop power and address capacityComprehensive point management10000 event logEditable quiescent display textExtensive special cause and effect programmingManual and automatic walk testAutomatic battery testDetector service functionsFront panel controls enabling text and configuration changesNetworkableUp to seven fully functional repeatersOptional easy-mount plateOptional expansion kit for mounting additional cards

GBP 1213.54
1

Fireclass FC500IP3 TCPIP Board for FC500 Fire Panels

Fireclass FCG-001 Fireclass Graphics Panel Software

Fireclass 4B-I Isolator Detector Base

FC410QMO Fireclass Quad Monitored Output Module

Fireclass 516.016.020FC ProReact Analogue Cable PVC 500m

Fireclass 508.070.005FC FCG Additional Client Licence

Fireclass 508.070.004FC FCG Software Licence 11-24 Panel

Fireclass 508.070.003FC FCG Software Licence 5-10 Panel

Fireclass 508.070.001FC FCG Software Licence - 1 Panel

Fireclass 508.070.002FC FCG Software Licence 2-4 Panel

Fireclass 557.202.811FC CPU801 Spare CPU

Fireclass 516.016.019FC ProReact Analogue Cable PVC 200m