Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke DetectorThe MR601TEx detectors react to the whole range of fire products from slow smouldering fires producing visible particles to open flaming fires producing large numbers of very hot smaller sized aerosols. It combines optical and heat detector technology to detect clear burning fire products which hitherto could only be easily detected by ion-chamber detectors.For normal ambient conditions the high-performance optical detector behaves as a normal optical detector. Only when a rapid rise in temperature is detected does the sensitivity of the detector increase and the presence of smoke will confirm a fire condition which will be transmitted as an alarm level.The MR601TEX overcomes the slower response of optical detectors to hot burning fires by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature. In this way it is intended to become a detector which will suit some of the risks currently covered by ion chamber detectors. Smoke detectors will not detect burning alcohol or other clean burning liquids which do not generate smoke particles.The MR601TEx detector is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus and is certified to ATEX Code Ex II 1G and Cenelec Code EEx ia IIC T5.Key FeaturesIntelligent Universal SmokeHeatCO detectorLow profile discreet and unobtrusiveSuperior performance and reliabilityDesigned for fast easy installationOptional locking kitMay be used in systems that meet BS5839 Pt 1Integral and remote alarm LEDCertified to ATEX Ex II 1GD and Cenelec Ex ia IIC T5Ex iaD 20 T100oCComplies to EN54-7 for Smoke Detectors and EN54-5 for Heat Detectors

GBP 84.19
1

Fireclass 516.061.001.YFC MDU601Ex Enhanced Carbon Monoxide Fire amp Heat Detector

Fireclass 577.001.035FC 601SB Conventional Sounder Base

Fireclass 2501033FC 24Vdc White Plastic Door Holder

Fireclass 2501034FC 230Vac White Plastic Door Holder

Fireclass 516.900.002FC 701PH Conventional Optical Heat Detector

Fireclass 516.900.002FC 701PH Conventional Optical Heat Detector

Fireclass 516.900.002FC 701PH Conventional Optical Heat DetectorThe Fireclass 701PH is a conventional optical smoke heat enhanced detector ideal for use with the Tyco FireClass range of conventional fire alarm control panels.The 701PH Optical and Heat Detector is suitable for normal ambient conditions where the high-performance optical detector behaves as a normal optical detector. Only when a rapid rise in temperature is detected does the sensitivity of the detector increase and the condition change. This is the first conventional detector from Johnson Controls to be certified to the EN54-29 standard for multi-sensors.The 700 Series Intelligent Conventional Fire Detection Range is the first conventional detector range from Johnson Controls that uses algorithms to determine fire conditions more precisely. This provides superior performance and improved false alarm rejection rates.Through innovative design the built-in micro-processors in the 700 Series detectors offer built-in drift compensation which extends the life of the detectors thereby reducing service costs to the customers. Installers only need one fitting to complete the installation.Key FeaturesDesigned for fast easy installationLow operational voltageAvailable as smoke fixed heat RoR heat and photo heatBackward compatibility with 600 seriesCompatible with 4B-D 4B and 5B basesLow profile and discreet designApproval to EN54 LPCB standardsImproved detection algorithmsBuilt-in drift compensationEN54 approval

GBP 11.09
1

Fireclass PS-12120FC 12 Volt 12 Ampere Battery

Fireclass 514.001.109FC MCP220Ex Conventional Weatherproof Intrinsically Safe Call Point

Fireclass PS-12170FC 12 Volt 17 Ampere Battery

Fireclass 4B-D Conventional Diode Base

Fireclass 516.900.004FC 702H Conventional Fixed Temp Heat Detector - 60C EN

Fireclass 568.001.018FC MC600 Relay Base

Fireclass 557.202.811FC CPU801 Spare CPU

Fireclass 516.900.005FC 703H Conventional Fixed Temp Heat Detector - 90C EN

Fireclass 516.900.003FC 701H Conventional Rate of Rise Heat Detector - 60C EN

Fireclass PS-12380FC 12 Volt 38 Ampere Battery

Fireclass 4B 4quot Detector Base

Fireclass 601CH Conventional Enhanced Carbon Monoxide Detector

Fireclass 601F Conventional Solar Blind Infrared Flame Detector

Fireclass 516.052.041.YFC MD611Ex Conventional Fixed Temperature Heat Detector

Fireclass 516.052.051.YFC MD601Ex Conventional Rate of Rise Heat Detector

Fireclass 516.900.001FC 701P Conventional Optical Detector

FireClass FC460PC Multi-Sensor Smoke Heat and Carbon Monoxide Detector

Fireclass 577.001.037FC 601SBD Conventional Diode Sounder Base

Fireclass 577.001.037FC 601SBD Conventional Diode Sounder Base

Fireclass 577.001.037FC 601SBD Conventional Diode Sounder BaseFireclass offer a choice of functional bases including the 601SBD EN54-3 approved low current sounder base with adjustable volume and tone. They do not require the use of a separate base and fit directly to a standard electrical box or the CTA adaptor plate.The Fireclass range of conventional detector ancillaries have been designed with the needs of the installer in mind. The range includes standard and diode bases sounder beacon and relay bases and the unique time saver ceiling tile adaptor.The 601SBD is for use in detection circuits complying with BS5839 Part 1 which requires that if callpoints are wired after detectors on a zone circuit the removal of a detector will not affect the operation of these callpoints. Removal of the detector should not prevent the sounder operating but will flag up a fault at the control panel.The 601SBD Diode Sounder Base provides eight tone and variable volume settings. It is identified by a green park clip.Key FeaturesAesthetically discreetSuperior performance and reliabilityDesigned for rapid installationManufactured to EN54 part 3.Integral sounder and detector baseVolume and tone adjustable after installationLow Power SynchronisationDo not require use of a standard baseSounder Base provides a sounder function on collective fire detection circuitsOperates independently of the detector circuit and may be used without an associated detectorRequires an external 24Vdc supply and provides eight tones and variable volume settings

GBP 171.46