Gent 8 Zone Auto Reset Fire Alarm Control Panel Gent 8 Zone Auto Reset Fire Alarm Control Panel, Auto Reset: Yes, Control Types: Cancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms, MPN: 75585-08 GBP 362.50 1
Gent 2 Zone Auto Reset Fire Alarm Control Panel Gent 2 Zone Auto Reset Fire Alarm Control Panel, Auto Reset: Yes, Control Types: Cancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms, MPN: 75585-02 GBP 213.20 1
Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel Gent 13270-08LB 8 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12. GBP 445.02 1
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel Gent 13270-04LB 4 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12. GBP 345.66 1
Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel Gent 13270-02LB 2 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12. GBP 256.49 1
Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less BatteriesBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12. GBP 349.91 1
Gent 13270-29 Flush Plate for 1-8 Panel and Repeat Panel Variants Gent 13270-29 Flush Plate for 1-8 Panel and Repeat Panel VariantsThe Gent 13270-29 is a flush mounting plate for the Gent Xenex fire alarm panel range. This product is ideal for giving a neat finish to a control panel that has been recessed into a wall.This part is compatible with the 1 2 4 and 8 zone Gent Xenex Panels along with the Gent Xenex repeater panel.Key FeaturesFlushing frame for Gent Xenex fire alarm panels and repeaterFits 2 4 or 8 zone panels GBP 67.94 1
Gent S4-34410 Single Channel Interface LV Input Gent S4-34410 Single Channel Interface LV InputInterfaces are used to link the fire alarm system to other plant management devices such as sprinklers and security systems. They can also be used to link to a zone of conventional detectors. The Vigilon system can accommodate a high capacity of single channel interfaces on the loop operating both inputs and outputs.The loop powered four channel interface range has individually sectored outputs with channel 1 set as a loop powered zone module. All interfaces are seen by the panel as one address although each inputoutput can have a separate label displayed at the panel. Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup.Key FeaturesGent Interface units are designed to provide heavy duty relay switching for 24V applications with contacts rated at 10AConnects directly to the Vigilon system GBP 74.74 1
Gent VIG-MIM-A3 A3 Zonal and Graphic Mimic Gent VIG-MIM-A3 A3 Zonal and Graphic MimicA Vigilon A3 Mimic panel VIG-MIM-A3 must be connected to a loop circuit of a Vigilon fire detection and alarm system. It is used to provide indication of fire events in the system. However it can also be used to provide indication of fault and supervisory events in the system. The panel can be mounted in landscape or portrait orientation. A Customised Mimic holds a pictorial overlay that represents the protected building or an area within.A fire event is indicated by the illumination of appropriate red LEDs behind the overlay to show the location of the fire. A Zonal Mimic provides a traditional zone by zone indication of a fire. Each zone is given a location label to identify the area within a building. The panel illumination defaults to a Zonal Mimic but can be reprogrammed during commissioning to be a Customised Mimic.An array of red lights illuminates individually or in groups. Illuminations may be applied to include custom shapes text and digital clock in small or large size. A site specific welcome message may be configured for display during quiescent conditions that can scroll if it is too long to fit the display area. First or last fire flashing option with in phase or anti phase flash. The panel has its own mains derived power supply with battery for standby power in the event of mains supply failure.Key FeaturesThe panel illumination defaults to a Zonal Mimic but can be programmed during commissioning to be a Customised MimicThe panel has its own mains derived power supply with battery Repeat Panels and Mimics require external power supplyThe panel is supplied with pre-printed and blank high quality UV protected A3 sheets GBP 2007.71 1
Gent S4-34450 4 Channel Interface IO PCB Only Gent S4-34450 4 Channel Interface IO PCB OnlyThe S4-34450 is a loop powered interface designed for use with the Vigilon range of fire alarm system control panels. This interface unit features 4 input output channels which can be used to control services within a building.Interfaces are used to link the fire alarm system to other plant management devices such as sprinklers and security systems. They can also be used to link to a zone of conventional detectors.The Vigilon system can accommodate a high capacity of single channel interfaces on the loop operating both inputs and outputs.The loop powered four channel interface range has individually sectored outputs with channel 1 set as a loop powered zone module.All interfaces are seen by the panel as one address although each inputoutput can have a separate label displayed at the panel.Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup.Key FeaturesLoop Powered devices reducing cost of installation and maintenanceIndividual addresses to maximise information and flexible cause and effectEach device with EN54-17 short circuit handling for enhanced system integrityComprehensive range of functionality in each device variant to simplify system designComplete range of mounting enclosures and accessoriesOptions to connect conventional fire detectors such as flame and beam detectorsCertified to EN54-17 and EN54-18 GBP 214.87 1
Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor amp Sounder Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor SounderThe GENT S4T-771-S Self-Test Dual Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 156.26 1
Gent S4T-710 S4 SELF TEST Optical Heat Sensor Gent S4T-710 S4 SELF TEST Optical Heat SensorThe GENT S4T-710 Self-Test Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 105.31 1
Gent S4T-711 S4 SELF TEST Dual Optical Heat Sensor Gent S4T-711 S4 SELF TEST Dual Optical Heat SensorThe S4T-711 Self-Test Dual Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 121.45 1
Gent S4T-770-S S4 SELF TEST Optical Heat Sensor amp Sounder Gent S4T-770-S S4 SELF TEST Optical Heat Sensor SounderThe GENT S4T-770-S Self-Test Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 134.18 1
Gent S4T-720 S4 SELF TEST Heat Sensor Gent S4T-720 S4 SELF TEST Heat SensorThe GENT S4T-720 Self-Test Heat Sensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 100.21 1
Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder Gent S4T-780-S S4 SELF TEST Heat Sensor and SounderThe GENT S4T-780-S Self-Test Heat Sensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 141.83 1
Gent 805595.10 Wireless Transceiver Interface Gent 805595.10 Wireless Transceiver InterfaceThis wireless transponder is designed for wall mounting. The wireless transponder communicates with up to 32 other wireless devices. These can be wireless of various types from intelligent automatic fire detectors or wireless interfaces with manual call points andor alarm signalling devices of the IQ8-family. Using the System IQ8ControlFlexES Control the wireless transponder integrates the intelligent automatic detectors with and without alarm signalling devices manual call point and IQ8Alarm Plus signalling devices in the esserbus esserbus-PLus via the wireless base andor wireless interface.The detector base allows esserbus integration of intelligent automatic detectors as bus devices with individual addressing via the transponder. Up to 10 transponders can be operated on one loop. The transponder can be linked with the loop as well as with a conventional detector zone or it can be operated as a stand-alone unit. Potential-free outputs for common fault and common fire are available. For system 8000 the transponder for RF devices can only be connected by using a potential-free relay to 4 IN2 OUT or 1 IN transponder because it is not compatible with panel 8000 and it cannot be used as a bus device.Key FeaturesRF communication with up to 32 usersmaximum 32 wireless basesmaximum 10 wireless interfaces with IQ8MCP manual call pointsmaximum 10 control groups for wireless interface with IQ8QuadIQ8Alarm Plus alarm signalling devicesesserbus integration of all RF. Devices as individually addressable usersThe RF devices can be assigned in up to 32 detector zonesAlarm and fault transmission in accordance with EN 54-2Connection to esserbus of IQ8Control FlexES Control panels as bus device as well as to a conventional detector zonesStand-alone operationPotential-free outputs for common fault and common fire GBP 1502.39 1
Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor Voice Sounder High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 189.40 1
Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor Voice Sounder High Power RedThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 235.25 1
Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 192.79 1
Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor Voice SounderThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 190.24 1
Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor Voice Sounder High Power Red VAD - BlackThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 319.33 1