Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

100 results (0,14083 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Haes SZAOV-1001 Single Zone AOV Panel

Haes HS-5101 Single Loop Analogue Control Panel

Haes HS-5101 Single Loop Analogue Control Panel

Haes HS-5101 Single Loop Analogue Control PanelThe HS-5100 series of control panels are supplied with a single loop driver card 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The Panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networkingOn board printer option M enclosure only20 zonal LED indicatorsProgrammable push buttons

GBP 1086.13
1

Haes MZAOV-1001A 3 amp AOV Control Panel - Single Zone Non Extendable

Haes MZAOV-1001A 3 amp AOV Control Panel - Single Zone Non Extendable

Haes MZAOV-1001A 3 amp AOV Control Panel - Single Zone Non ExtendableMZAOV-1001A is a single detection zone non extendable smoke vent control panel with integral 3 amp power supply designed to control 24vdc actuators or magnets.The panel has battery backup capability and assures that actuators can be powered in the event of a mains failure.Vent controls and indications are provided on the front of the control panel with a large graphical LCD display and integral control inputs to accept signals from remote contacts smoke detectors and manual controls.Optional support for Rain Sensor and PIR inputs for environmental control and trap injury protection plus 010v inputs and outputs to allow control interfacing with BMS systems and positional control Act output.The MZAOV control panel range has been developed to provide a comprehensive solution to smoke vent control scenarios.Key Features3 amp integral PSULarge graphical displayEasy to programSingle detection zone Conventional or Twin-wireInput from other detection systems to activateMonitored Actuator output for controlling smoke ventsSwitch input to control wide combination of ventsFireman switch input to override all other inputsAll inputs and actuator outputs monitored for Short and Open CircuitUser switch inputs configurable as local fireman switchesThermostat input - Ventilation mode. Vents openable in 10 stepsOptional support for Rain sensor PIR and BMS controlMonitoring of unused inputs and outputs can be disabled

GBP 545.29
1

Haes ESG-1002 Esprit Extinguishant Control Panel Single Flood Area 3.4A PSU

Haes ESG-1001 Esprit-G Extinguishant Control Panel Single Flood Area 1.2A PSU

Haes ESG-1001 Esprit-G Extinguishant Control Panel Single Flood Area 1.2A PSU

Haes ESG-1001 Esprit-G Extinguishant Control Panel SingleFlood Area 1.2A PSUThe Esprit extinguishant release control panels are fullyconfigurable to control automatic extinguishant release scenarios. The single flood area control panel has 3 detection circuitsand support for metron and solenoid type actuators. Programmable countdowntimers are provided for Extinguishant Delay Extinguishant Duration FloodingTime and Extract Time. The control panel has a large graphical display witheasy to navigate menus. Remote status units are available as well as remoteHold Off Abort Buttons.Esprit-G panelssupport a large range of conventional detectors including Apollo Hochiki Nittan. The panels are supplied with a 1.2 or 3.4 amp internal switchmode power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging.Esprit-G panels are approved to European standards EN12094-1 EN54-2 EN54-4.Key FeaturesSingle flooding area3 detection zonesApproved to EN12094-1 EN54- 2 EN54-4Fully configurable zone voting for gas release4 programmable sounder circuitsConfigurable sounder delaysZero time delay option for manual call pointsCompatible with IS barriersNon-latching zone input optionExtinguishant delay 0-60 secondsExtinguishant duration 1-300 secondsFlooding time 60-1800secondsExtract time 1-90 minutesGraphical back lit LCD displayAccess controls via key switch or code entryTime and date stamped event logAlarm counterCompany logo can be programmed in displayRS 485 communications for remote status unitsKey switch status controlFire fault stage signal relays2 amp actuator circuitHold abort flow switch manual release mode control andpressure switch monitoring inputs1.2 amp PSU for 7Ah batteries

GBP 432.04
1

Haes ESG-2002 Esprit Mini Remote Status Unit

Haes Red Fire Alarm Mains Isolate Switch with Back Box - FAIS-R-B

Haes Lockdown Alert Alarm Relay

Haes CWSS-RB-S8 Sounder Beacon - Red Body - Red Lens - First Fix

Haes CWSS-RB-S7 Sounder Beacon - Red Body - Red Lens

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 370.74
1

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 317.90
1

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 294.74
1