Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire Panel 2 - 8 Zone
Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire PanelThe Sigma CP-A AlarmSense range consists of a series of conventional two four and eight zone fire alarm control panels. The AlarmSense system enables all detection and sounder devices in a given zone to be wired to the same pair of cables greatly reducing the cabling and installation requirements and hence costs.The AlarmSense range of devices includes smoke and heat detectors call points base sounders base sounderbeacons and relay units all wired to the same pair of cables. Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common zonal or two-stage alarms by simply setting one of the panels configuration options.Selection of the AlarmSense local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode alarms are restricted such that only the sounder connected to the activated detector will operate initially.The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset a general alarm will sound throughout the premises. The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or call outs while still providing secure high quality fire protection throughout the premises.Key Features2 wire systems reduces installation cabling2-wire repeaters and ancillary boards via serial busFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay for detectors onlyZonal sounder delay for call points onlyCoincidence output via ancillary boardShort circuit fire selectable by zoneNon latching selection by zoneSilent zones common sounder outputsZone input delay for sprinkler system connectionAlarmSense local alarm feature supportedSimple single board constructionInstaller friendlyCompatible with all AlarmSense devicesTwo conventional monitored sounder outputs3 Amp power supplyAuxiliary power outputFully certified to BS EN54-2 and BS EN54-4Allows systems to be installed in accordance with BS5839 Part 6Variants AvailablePart NumberDescriptionKA11020M2Sigma CPA Alarmsense Conventional Panel 2 Zones SurfaceKA11040M2Sigma CPA Alarmsense Conventional Panel 4 Zones SurfaceKA11080M2Sigma CPA Alarmsense Conventional Panel 8 Zones Surface