Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

77 results (0,15956 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec MM-24-00-00-6PS3 Addressable Matrix Panel CW PSU

Kentec Syncro Ident Programmable LED Indication Panel 24 Way

Kentec Syncro Ident Programmable LED Indication Panel 24 Way

Kentec Syncro Ident Programmable LED Indication PanelSyncro Ident panels provide a compact and attractive display for up to 24 indications from a Syncro or Syncro AS fire control panel. As with all inputs and outputs on the Syncro system each indicator is fully programmable to indicate a variety of events as well as being fully programmable via cause and effects to operate in response to logically connected inputs. Each indication defaults to a zonal fire indicator but may be configured via the Loop Explorer configuration utility to operate upon any event type or combination of inputs.Requiring only a low current 24V power supply and a 2 core data connection to the fire panel Syncro Ident panels can be installed quickly and easily to provide supplementary information on the status of the fire alarm system with the minimum of cost and effort. The compact slimline enclosure is unobtrusive and is ideal for mounting in locations where a larger control and indication unit would be unsuitable. Each indication has a dedicated field for customized text to provide a concise description of the indication. Multiple Syncro Ident panels can be connected to the Syncro serial bus to provide a diverse range of indications at multiple locations.Key Features8 and 24 LED versions available as standardLarge versions available to special orderUp to 16 x 24 ways Syncro Ident can be connected to each fire panelProgrammable flashing or steady statesRed yellow or green indications optionsCommon Fire Fault and Disabled indicationCustomisable label identification tagsBuzzer with silence control and re-soundLamp test controlLow power 24V DC supplyConnects to 2 wire Syncro RS485 data busMultiple language options

GBP 384.62
1

Kentec K1619911 Battery Box to Match Syncro Styling Max 24 AH Battery Surface

Kentec Syncro AS Lite Single Loop Surface Control Panel LA80161M2 - Apollo Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LH80161M2 - Hochiki Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LV80161M2 - Argus Vega Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LH81161M2 - Hochiki Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LA81161M2 - Apollo Protocol

Kentec Syncro AS Lite Single Loop Surface Control Panel LV81161M2 - Argus Vega Protocol

Kentec K1885-48 Sigma A-CP Conventional Annunciator Panel Grey

Kentec K1885-18 Sigma A-CP Conventional Annunciator Panel Red

Kentec K41102SST Disabled Refuge 2 Line Central Unit

Kentec K41232SST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41232SST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41232SST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Surface MountingThe Disabled Refuge 32 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 17Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel32x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 5784.11
1

Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED DisplayThe master panel can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired inline with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesRadial WiredFlush mounting8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2450.78
1

Kentec K41216SST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41216SST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41216SST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Surface MountingThe Disabled Refuge 16 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features16x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 4415.09
1

Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 8 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is wired to disabled refuge outstations by a loop type circuit. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.There is space for 7Ah batteries provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2371.82
1

Kentec K41232FST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41232FST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41232FST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 32 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 17Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel32x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 5441.84
1

Kentec K41108SST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108SST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108SST Disabled Refuge8 Line Central Unit with OLED DisplayThe Disabled Refuge8 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2404.33
1

Kentec K41216FST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41216FST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41216FST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 16 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features16x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 4072.82
1