Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

67 results (0,16831 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A

GBP 734.00
1

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone ConventionalSigma XT control panels are multi-area extinguishantcontrol panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones ofconventional detection with up to 4 extinguishant areas are available.Standalone extinguishant control units are also availablewith 2 monitored inputs to receive initiating signals from remote firedetection control panels or addressable modules.Each Extinguishant area has a comprehensive set of inputsand outputs and is configurable via a simple programming interface. Allextinguishant areas may have up to 7 serially connected Sigma SI statusindication and control units or ancillary relay boards connected via a simple 4core cable. The versatility of the control panel can be enhanced further by thefitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort input

GBP 2019.97
1

Kentec Syncro 4 Way Conventional Detection Zone Module K545

Kentec Sigma CP 4 Zone Conventional Fire Alarm Panel K11040M2

Kentec Sigma CP 4 Zone Conventional Fire Alarm Panel K11040M2

Kentec Sigma CP 4 Zone Conventional Fire Alarm PanelK11040M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration

GBP 318.37
1

Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2

Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2

Kentec Sigma CP2 Zone Conventional Fire Alarm PanelThe Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11 range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configurationSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power output

GBP 300.32
1

Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2

Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2

Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration

GBP 361.14
1

Kentec Sigma XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1 K11031M2

Kentec Sigma XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1 K11031M2

Kentec SigmaK11031M2XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1Designed and manufactured to the highest standards in a quality controlled environment and with European EN12094-1 approvals the Sigma XT K11031M2 extinguishant releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations. With three detection zones as standard extinguishant release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three type activations such as would be required for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma XT K11031M2 allow the functionality of the system to be extensively modified while still complying with the requirements of the controlling standard for the equipment EN12094-1 EN54-2 and EN54-4. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until extinguishant release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the extinguishant system status. With all of the electronics mounted on a single easily removable steel plate Sigma XT panels are both robust and easy to install. Sigma XT is supplied in an enclosure that matches the design and colour of the Sigma CP range.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-4Three detection zones as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage sounder delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable extinguishant delays up to 60 seconds in 5 second stepsConfigurable extinguishant duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until releaseSupports up to seven four wire status indicatorsBuilt in Extract Fan control

GBP 587.21
1

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V Grey

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V Grey

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V GreyThe Sigma A-CP is a range of conventional fire control panels with an optionalbuilt-in communicator.With two four or eight initiating circuits all panels can be extensivelyconfigured via a simple front panel operated programming method.The low standby power requirements and cost effective small batteries allowthe panel to be mounted in a discrete enclosure which is available in red orgrey.A simple programming method using just 3 front panel buttons allows anextensive list of configuration options to be set and reviewed.Single board construction enables easy removal of all electronic parts byremoving just two screws and ample provision of cable entry knockoutssimplify installation.4 Amp notification appliance power and built-in selectable sync protocolsprovide ample power and control for a wide range of standard notificationappliances.The built-in RS485 communications bus provides the facility to connect 4wire annunciators or ancillary relay boards to provide further indication andcontrol options throughout a premises.The optional DACT allows dual line reporting to central stations and providesa 500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1