Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

242 results (0,17225 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde Airsense Stratos to 10mm Compression Adaptor

Kidde Airsense Stratos 34 Female to 25mm Male Adaptor

Kidde Airsense Stratos 27mm Socket 34 Female to 25mm Female

Kidde Airsense Stratos 25mm Female to 34 Male Adaptor 9-10952

Kidde FP2864C-99 2000 Series - Addressable Fire Panel with 2 to 8 loops 16 - 64 Zones - English UK

Kidde FP2864C-99 2000 Series - Addressable Fire Panel with 2 to 8 loops 16 - 64 Zones - English UK

Kidde FP2864C-99 2000 Series - Addressable Fire Panel with 2 to 8 loops 16 - 64 Zones - English UKThe FP2864C is a versatile addressable fire panel supplied with 2class-A loops. In addition to a generous backlit LCD display itprovides LEDs for indicating both fire and fault conditions with textdescriptions for 16 fire zones on the front panel user interface. Thepanel may be upgraded with an additional 6 class-A loops as well as48 zone indicators full inter-panel networking facilities on both copperor fibre as well as with a LON network bus that supports the AritechLON700 devices and repeaters amongst others.The FP2864C provides extensive maintenance features boastspowerful IO programming and supports both Aritech 2000 and 900series protocols.The FP2864C offers multiple auto-configuration options with extensiveauto detection facilities facilitating quick initial setup even for largesystems. Multiple repeaters in various formats may be connected overa 2-wire network with both class-A and B operating modes whilst up to31 fire panels may be networked together for large applications.In addition to the comprehensive information LEDs the panels largeLCD display allows for every device in the system to be described withup to 80 characters of descriptive text as well as 40 characters forzone descriptions. Complete statistics and graphics indications forevery device are available.Several mechanisms for preventing false alarms including floatingbackground with automatic compensation double knock andcoincidence mode within and between zones as well as soak testfacilities allow the user complete piece of mind.Key FeaturesConfiguration maintenance and graphic PC software supportUp to 128 device addresses per loopFull interpanel network optionsFull range of repeaters and LON700 devices including Dutch andScandinavian fire brigade panels and Scandinavian alarm delay unitsNetworkable black box panelsPower supply for 72-hour autonomyDefault start-up and service modesProgrammable service reminders on-line diagnostics and statisticsMaintenance warnings and soak testing faciltiesOne-man maintenanceFloating background and drift compenstationProgrammable daynight functionalityCoincidence within and between zonesTimed and manual zone controlIO programming with Boolean functions maximum allocated input memory 300Scandinavian variants with Scandinavian firemans key availableEN54 and CPD certified

GBP 2294.45
1

Kidde Airsense EST-DMS Zone Microphone

GBP 866.45
1

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control PanelThe Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel is a ULFM listed extinguishing control panel designed and manufactured to the highest standards in a quality controlled environment. With UL and FM approvals it offers outstanding value and performance for small to medium sized fixed firefighting installations. FireBeta A-XT is supplied in a red enclosure.The 3 initiation circuits allow extinguishant release to be configured to activate from any combination of detection zone inputs. This allows among others any 2 zones from the combination of 3 to activate release making it ideal for applications protecting ceiling room and floor voids.The extensive configuration options of the FireBeta A-XT allow the functionality of the system to be extensively modified. A large LED display on the panel fascia enables easy configuration and control. It additionally displays the time remaining until extinguishing agent release for added user safety.Key FeaturesUL864 and FM listedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stepsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining to releaseSupports up to seven four wire status indicatorsBuilt in extract fan control

GBP 536.48
1

Kidde KE-DBA-ADPW-ZIT Intelligent Addressable Base Accessory - Ziton Adapter White

Kidde KE-DBA-ADPW-ZIT Intelligent Addressable Base Accessory - Ziton Adapter White

Kidde KE-DBA-ADPW-ZIT Intelligent Addressable Base Accessory - Ziton Adapter WhiteThe KE-DBA-ADPW-ZIT is an Excellence series base adapter. It allows easy migration form a legacy Ziton ZP7 series installation by offering the possibility to keep the legacy standard base installation intact but convert to the new Excellence series intelligent detectors.Standard BaseThe adapter base is designed to enable the new Excellence series detectors to be plugged in without any need for force - particularly useful when fitting to suspended ceilings. To make it even easier the base has a one way only fit.The adapter base contains no electronic parts that could be damaged during installation. It automatically locks into the legacy standard base just like fitting a detector The adapter also supports the option to lock the Excellence series detector in place to avoid unauthorised detector removal.As with all Excellence series standard bases the Excellence series base adapter supports Excellence series address tags for neat product identification labelling.Key FeaturesAllows the reuse of legacy Ziton ZP7 standard bases without installation modification in systems upgrading to the new intelligent Excellence series detectorsAutomatic locking to legacy base avoids adapter removal when the new detector is removedSupports the Excellence detector base locking option to prevent unauthorised removal of the Excellence series detectorStandard Excellence series base already integratedHides the legacy base for perfect colour matching to the new Excellence series detectorSupports Excellence series address tags for neat labelling and device identificationEN54 approved with the Excellence series detectors

GBP 11.21
1

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman MicrophoneA EST ENT VES fireman microphone is a monitored external device working with Control Units in a redundant communication ring. It can thereby perform a superior function of a system control unit too.A fireman microphone can be used to activate alarm messages as well as general public announcements to choose individual zones and to broadcast live voice messages. It is equipped with programmable function keys which can be used to assign functions as required. Up to 5 EST-EKB-20M keyboard extensions with additional function keys can be attached to a fireman microphone.A CPU switch enables immediate and direct broadcasting of announcements to all zones without any involvement of the control system even during a failure of the central processor. The microphone is able to automatically detect a key failure and an audio path from the microphone capsule inclusive to the Control Unit. A fireman microphone is also equipped with an intercom function and is able to communicate with other microphones in the system.Key FeaturesMonitored microphone and connection of the microphone module to the systemA dedicated evacuation key 3 fully-programmable keys with a possibility of connecting up to five 20-key extensionsBuilt-in 2 contact inputs and 2 relay outputsPOE or external feeder-based power supplyBlack-box function recording all announcements played during an alarmBuilt-in SFP modules and CAT5e for simplicity of implementation of the loop topologyRS485 for communication with external systemsIntercom function between all fireman and zone microphones

GBP 1256.28
1

Kidde 1-23911-K069 FireBeta XT Extinguishing Control Panel 3 Zone 1 Area

Kidde 1-23911-K069 FireBeta XT Extinguishing Control Panel 3 Zone 1 Area

Kidde 1-23911-K069 FireBeta XT Extinguishing Control Panel 3 Zone 1 AreaFireBeta XT extinguishing control panels are designed andmanufactured to the highest standards in a quality controlledenvironment. With its EN12094-1 approvals it offers outstanding valueand performance for small to medium sized fixed firefightinginstallations.The FireBeta XT is supplied in an enclosure that matchesthe design and colour of the status unit range.The 3 detection zone circuits allow extinguishing agent release to beconfigured to activate from any combination of detection zones. Thisallows among others any 2 zones from the combination of 3 toactivate release making it ideal for applications protecting ceilingroom and floor voids.The extensive configuration options of the FireBeta XT allow thefunctionality of the system to be extensively modified to suit theapplication while still complying with EN12094-1 EN54-2 and EN54-4.A large LED display on the panel fascia enables easy configurationand control. It additionally displays the time remaining untilextinguishing agent release for added user safety.The control panel status can be displayed on up to 7 remote statusindicators. This allows the agent release status to be displayed at fore.g. multiple entrances to a protected area adding additional usersafety. The communication between the panel and its status indicatorsis fully monitored.The internal electronics are mounted on a single easily removablesteel plate making the FireBeta XT robust and easy to install.Key FeaturesEN12094-1 EN54-2 and EN54-4 approvedThree detection zones as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage sounder delaysConfigurable detection delaysZero time delay for manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems e.g. aspiration systems Configurable extinguishing agent delays up to 60 seconds in 5 second stepsCountdown timer shows time remaining until releaseSupports up to seven four wire status indicatorsBuilt in extract fan control

GBP 509.66
1

Kidde AirSense ModuLaser Pipe Adaptor Straight Replacement Fitting 9-30796

Kidde AirSense ModuLaser Pipe Adaptor Bend Replacement Fitting 9-30795

Kidde 1-23911-K071 FireBeta XT Status Indicator

Kidde 1-23911-K071 FireBeta XT Status Indicator

Kidde 1-23911-K071 FireBeta XT Status IndicatorThe Kidde 1-23911-K071 FireBeta XT Status Indicator is an accessory to the EN approved FireBeta XTXT extinguishing control panels. They provide detailed status information via 6 high bright LEDs on the status of the extinguishant release control. A LED display shows a countdown of the time remaining in seconds until the extinguishant is released. Status units are normally mounted at various access points into the risk area for notification for safety purposes.Output FunctionsThe following area statuses are signalledManual onlyAutoManualHold activatedDisabledImminentReleasedInput FunctionsTwo supervised inputs are provided on every status unit.AutoManual control An input is provided on the status unit to monitor a door interlock system. This provides additional safety for unmanned areas. Door monitoring interlocks may be fitted to all access points into the risk area which when connected to the status unit automatically changes the operating mode for the extinguishing area between automatic and manual status as the door is locked or unlocked.Extinguishing Hold control By connecting a dedicated hold button to this input activating this button allows the extinguishant release countdown to be stopped while the hold button is active.InstallationEvery status unit is provided in a rugged steel enclosure for surface mounting. Up to 7 status units may be connected to the FireBeta XTXT control panel via a fully monitored RS485 communication link of up to 1200 m.Key FeaturesFour wire connection data and powerRobust high quality surface mount enclosureUp to 7 units per panelEasy access to terminals for easy installationRemote automanual door interlock and extinguishing hold supervised inputsInternal fault diagnosis indicatorsInternal buzzer

GBP 161.27
1

Kidde Airsense APIC Card Notifier Protocol 9-30433

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit. EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems. It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity.In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers.If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier. The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 1823.00
1

Kidde 1-23911-K073 FireBeta XT Status Indicator With Key Switch

Kidde 1-23911-K073 FireBeta XT Status Indicator With Key Switch

Kidde 1-23911-K073 FireBeta XT Status Indicator With Key SwitchThe Kidde 1-23911-K073 FireBeta XT Status Indicator with Key Switch is an accessory to the EN approved FireBeta XTXT extinguishing control panels. They provide detailed status information via 6 high bright LEDs on the status of the extinguishant release control. A LED display shows a countdown of the time remaining in seconds until the extinguishant is released. Status units are normally mounted at various access points into the risk area for notification for safety purposes.For systems where local control of the AutomaticManual mode are required the Kidde 1-23911-K073 FireBeta XT Status Indicator with Key Switch units are supplied with this control fitted. It allows the extinguishing system operation to be locally changed from automatic to manual mode on the status unit.Output FunctionsThe following area statuses are signalledManual onlyAutoManualHold activatedDisabledImminentReleasedInput FunctionsTwo supervised inputs are provided on every status unit.AutoManual control An input is provided on the status unit to monitor a door interlock system. This provides additional safety for unmanned areas. Door monitoring interlocks may be fitted to all access points into the risk area which when connected to the status unit automatically changes the operating mode for the extinguishing area between automatic and manual status as the door is locked or unlocked.Extinguishing Hold control By connecting a dedicated hold button to this input activating this button allows the extinguishant release countdown to be stopped while the hold button is active.InstallationEvery status unit is provided in a rugged steel enclosure for surface mounting. Up to 7 status units may be connected to the FireBeta XTXT control panel via a fully monitored RS485 communication link of up to 1200 m.Key FeaturesManual only Automatic Manual mode select key switchFour wire connection data and powerRobust high quality surface mount enclosureUp to 7 units per panelRemote automanual door interlock and extinguishing hold supervised inputsEasy access to terminals for easy installationInternal fault diagnosis indicatorsInternal buzzer

GBP 180.37
1

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems.It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity. In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers. If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier.The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system. Furthermore EST-CU-11LT can be equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system such extended configuration is included in EST-CU-11LCD Control Unit.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 2213.64
1

Kidde Airsense Quick Release Airline Valve 9-10976

Kidde Airsense Quick Release Airline Valve 9-10976

Kidde Airsense Quick Release Airline Valve 9-10976When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With introduction of the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process. The low pressure compressed air can now be easily connected to the quick release.At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy connection of airlineRobust ball valve to protect ASDFor use with 9-10978 - check valve

GBP 82.97
1

Kidde N-MC-FE Glass Trigger Element For Intelligent Manual Call Points Pack of 10

Kidde N-MC-FE Glass Trigger Element For Intelligent Manual Call Points Pack of 10

Kidde N-MC-FE Glass Trigger Element For Intelligent Manual Call Points Pack of 10The N-MC-FE is a glass trigger element for compatible Type-A series manual call points. It may be used as alternative for resettable elements that are normally used in these manual call points. The N-MC-FE allows the manual call point to be easily activated without the need for tools.The N-MC-FE uses clear black print on a brilliant white background. An arrow on either side pointing inwards towards a dot indicates to the operator where to push on the element to activate the manual call point.Installation of the frangible element in a compatible manual call point is made easy by the design of the manual call point. Using the test key the front cover of the manual call point is removed allowing the insertion of the N-MC-FE with a quick and simple action.The coated glass element is designed to break easily and safely across a vertical running break guide consistently in the same place. Little force is required to break the element eliminating the need for special tools to facilitate activation. The glass coating ensures no splintering of the glass avoiding possible injury to the operator during the activation process.Key FeaturesQuick installation without special toolsEasy to retrofitCoated glass prevents operator injury by controlling the glass break and avoiding glass fragmentsEasy break glass for smooth and consistent breaks in the same positionEasy to operate without the need for hammersEN54 certified with compatible manual call points

GBP 15.40
1