Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

19 results (0,14581 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley EVCS-TASP4 4-Way Splitter Emergency Assist

Morley ZX 4-Way Programmable Output Relay Module

Morley ZX 4-Way Programmable Sounder Card

Morley Intelligent Hand-Held Diagnostic Test Unit for Analogue Loops POL-200-TS

Morley Intelligent Hand-Held Diagnostic Test Unit for Analogue Loops POL-200-TS

Morley Intelligent Hand-Held Diagnostic Test Unit for Analogue Loops POL-200-TSThe POL-200-TS loop tester is a versatile measurement and analysis tool that assists technicians with the installation and maintenance of fi re detection systems. The POL-200-TS recognizes all addressable loop elements with the CLIP OPAL ADVANCED Notifier Morley-IAS System Sensor and Honeywell protocols. In addition the loop tester is portable and easy to use so you can work loop by loop before the panel is installed from any location on the loop.Innovative InterfaceUsing the device is simple graphical touch screen with user-friendly icons and clear automated one-touch functions. It can even be used while wearing gloves.Loop MappingThe mapping function uses the device isolators to check the loop cabling topology and map the loop. On the screen it is possible to see the production date and detailed information of detectors inputs and outputs. Similarly one can read the status of equipment or even detect internal equipment faults.Maintenance and TestingThe log function generates a data fi le including information regarding the status of each loop device. It allows accurate control of system operation through the loop and device status report to anticipate and record equipment maintenance tasks.Simple OperationThe touch screen is designed for maximum simplicity with intuitive icons. The device performs the functions automatically when these are selected. The loop display clearly identifies the equipment type position and number of loop components.Key FeaturesVerification and maintenanceColour touch-screenUser-friendly functionalityCompatibility with CLIP OPAL ADVANCED Notifier Morley-IAS System Sensor and Honeywell protocolsTesting of loop faults short circuits from positive and or negative to shieldingDetailed information and device controlStatus logInternal memory and USB port for PC connection update or download recordings12VDC power supply or internal batteries

GBP 2138.72
1

Morley EVCS-HANDSET Remote Jack Handset

Morley MI-DCMOE Output Control Module

Morley Network 16 Digital Master Panel EVCS-MPX-16

Morley HON-CGW-MBB Fixed CLSS Gateway Ethernet and Wifi

Morley MI-DCZRM Non-Addressable Zone Monitor Module

Morley MI-DCZRM Non-Addressable Zone Monitor Module

Please note This product is now obsolete however we may still have some in stock. The replacement is theMorley MI-DCZRME Analogue Addressable Monitor Module.Morley MI-DCZRM Non-Addressable Zone Monitor ModuleThe MI-DCZRM addressable zone monitor module allows a zone of non-addressable devices to communicate with a Morley-IAS protocol analogue addressable system. As a result existing non-addressable zones can be integrated into a Morley-IAS protocol system. The module monitors a zone of two-wire non-addressable devices.Each MI-DCZRM uses one of 99 available module addresses on a loop. A fault signal will be transmitted to the panel in case of an open circuit or short circuit on the non-addressable zone wiring or when the external fault input is pulled low can be used for power supply monitoring. A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm subject to current limitations.Key FeaturesConnection of a zone of non-addressable detectors to an analogue addressable fire systemBuilt in isolation allowing system installation in stages without loss of protectionMonitors open circuit and short circuit faultsTRI-Colour Status LEDZone powered from addressable loop wiring or external 24V PSURemote reset of non-addressable zoneMonitoring of external power supplyExternal fault inputCPD approval to EN54-17 and EN54-18 LPCB and VdSDIN rail mountable consistent with all other modulesSupport for an extended power supply range as low as 18Vdc 60mA with an External PSU

GBP 82.21
1

Morley HLS-RES-V3AI Response Aid Paging System V3

Morley HLS-RES-V3AI Response Aid Paging System V3

Morley HLS-RES-V3AI Response Aid Paging System V3The Response Paging System offers the latest innovations in wireless paging and monitoring. Its a cost effective and flexible system that provides the ability to quickly respond to activated alarms.The Response Aid paging unit consists of a wall-mounted HIPS High Impact Polystyrene enclosure containing a 4 watt transmitter enclosed in an aluminium surround. It includes a 240-volt 3-pin plug status indicator LED for Power and Transmission and straight wire antenna connected to the top of the enclosure using a 38 BNC bayonet connection.The unit has the capability of 15 dry contacts 7 inputs and 8 outputs. The Input contacts can be set to normally open NO or normally closed NC with the Output contacts being normally open NO. An input contact on one paging transmitter can trigger and output contact on another Response paging transmitter on the same site widening the scope and application that Response Plus can be installed.In the event of transmitter failure power supply failure and a loss in power output from the transmitter there is a Fault output normally closed alarm accessible via internal terminal header. This is to be connected back to the fire alarm panel to alert the fire alarm panel of any failures. The system includes battery backup as standard for a minimum 24 hours after mains power failures. There is a low voltage detection sounder which will alert in the event of low battery.The Response Aid transmitter is fully site programmable via the internal LCD display and mini keypad. The transmitter can be programmed to support and range of Honeywell fire control panel platforms and additional 3rd party protocols.

GBP 2848.23
1

Morley D2E Duct Detector Housing with B401 Base

Morley D2E Duct Detector Housing with B401 Base

Morley D2E Duct Detector Housing with B401 BaseThe InnovairFlex 2DE 2-wire photoelectric duct smoke detector features a pivoting housing that fits various applications both square and rectangular footprints mount to round or rectangular duct work. The new duct smoke detector senses airflow speeds ranging from 1.5-20m per second with proven precision. The enhancements built into this model improve false alarm immunity with plug-in sensor head broaden operation temperature -20 to 70 degree and humidity 0 to 95 percent non-condensing ranges while simplifying installation and maintenance. These advance features can detect smoke even in the harshest duct applications.The new design provides more wiring space with an added 20mm conduit knockout. Numbers and labels for terminal designations are consistent with previous Innovair models. The new sampling tube can be clicked into position with one smooth motion from either the front or the back of the detector.The InnovairFlex D2E duct smoke detector has signals to indicate trouble and maintenance conditions. Additionally a cover tamper feature is incorporated to indicate a trouble condition for removed or improperly installed sensor cover. An improved cover design with an integrated low-flow feature isolates the sensor head from low-flow technology for simple maintenance.Key FeaturesPhotoelectric integrated low-flow technologyAir velocity rating from 1.5 ms to 20.3 msecVersatile mounting options in square or rectangular configuration with modular constructionPlug-in sensorSuperb false alarm immunity with the latest sensor technologyBroader ranges for operating temperature -20C to 70C and humidity 0 to 95 non-condensingPatented sampling tube installs from front or back of the detector with no tools requiredA cover tamper feature to indicate a trouble condition for removed or improperly installed sensor coverIncreased wiring space with 15mm and 20mm conduit knockoutImproved LED status24 VDCBackward compatibility with existing DH400 range including remote accessoriesPlease Note this product does not come complete with a detector please use the 2351E.

GBP 215.50
1