Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

24 results (0,13832 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley MI-DCZRM Non-Addressable Zone Monitor Module

Morley MI-DCZRM Non-Addressable Zone Monitor Module

Please note This product is now obsolete however we may still have some in stock. The replacement is theMorley MI-DCZRME Analogue Addressable Monitor Module.Morley MI-DCZRM Non-Addressable Zone Monitor ModuleThe MI-DCZRM addressable zone monitor module allows a zone of non-addressable devices to communicate with a Morley-IAS protocol analogue addressable system. As a result existing non-addressable zones can be integrated into a Morley-IAS protocol system. The module monitors a zone of two-wire non-addressable devices.Each MI-DCZRM uses one of 99 available module addresses on a loop. A fault signal will be transmitted to the panel in case of an open circuit or short circuit on the non-addressable zone wiring or when the external fault input is pulled low can be used for power supply monitoring. A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm subject to current limitations.Key FeaturesConnection of a zone of non-addressable detectors to an analogue addressable fire systemBuilt in isolation allowing system installation in stages without loss of protectionMonitors open circuit and short circuit faultsTRI-Colour Status LEDZone powered from addressable loop wiring or external 24V PSURemote reset of non-addressable zoneMonitoring of external power supplyExternal fault inputCPD approval to EN54-17 and EN54-18 LPCB and VdSDIN rail mountable consistent with all other modulesSupport for an extended power supply range as low as 18Vdc 60mA with an External PSU

GBP 82.21
1

Morley Horizon 2 Zone Conventional Fire Alarm Control Panel

Morley Horizon 2 Zone Conventional Fire Alarm Control Panel

Morley Horizon 2 Zone Conventional Fire Alarm Control PanelThe Horizon series of conventional control panels has been developed to provide a simple and reliable solution to the demands of todays fire detection solutions. The Horizon range has been designed with both installer and end users requirements in mind. For installers Horizon offers an out of the box and on the wall solution.A combination of quick installation an enhanced feature set and advanced programming allows installers to meet the demands of the user quickly and simply. Equipped with configurable class change inputs coincidence detection programmable delays to allow alarm verification and the facility to interface to larger house alarm systems.For end users clear visible indications easy to operate functions and a big red key to activate the control buttons make for simple and unambiguous operation. Engineered and built to the same high standard as all Morley-IAS control panels the Horizon system forms an essential part of any fire alarm solution.The Horizon series of conventional control panels has been designed for use in small to medium commercial environments. It is especially suitable for Garages Retail Units Shops Restaurants Doctors Surgeries Public Offices and Nursery Schools.Key FeaturesSimple user friendly designSimple to installIntuitive to use2 4 or 8 ZonesWalk testEnhanced feature setMultilingual text insertsDesigned to comply with EN54 part 2 and part 4

GBP 242.35
1

Morley Horizon 8 Zone Conventional Fire Alarm Control Panel

Morley Horizon 8 Zone Conventional Fire Alarm Control Panel

Morley Horizon 8 Zone Conventional Fire Alarm Control PanelThe Horizon series of conventional control panels has been developed to provide a simple and reliable solution to the demands of todays fire detection solutions. The Horizon range has been designed with both installer and end users requirements in mind. For installers Horizon offers an out of the box and on the wall solution.A combination of quick installation an enhanced feature set and advanced programming allows installers to meet the demands of the user quickly and simply. Equipped with configurable class change inputs coincidence detection programmable delays to allow alarm verification and the facility to interface to larger house alarm systems.For end users clear visible indications easy to operate functions and a big red key to activate the control buttons make for simple and unambiguous operation. Engineered and built to the same high standard as all Morley-IAS control panels the Horizon system forms an essential part of any fire alarm solution.The Horizon series of conventional control panels has been designed for use in small to medium commercial environments. It is especially suitable for Garages Retail Units Shops Restaurants Doctors Surgeries Public Offices and Nursery Schools.Key FeaturesSimple user friendly designSimple to installIntuitive to use2 4 or 8 ZonesWalk testEnhanced feature setMultilingual text insertsDesigned to comply with EN54 part 2 and part 4

GBP 444.77
1

Morley Horizon 4 Zone Conventional Fire Alarm Control Panel

Morley Horizon 4 Zone Conventional Fire Alarm Control Panel

Morley Horizon 4 Zone Conventional Fire Alarm Control PanelThe Horizon series of conventional control panels has been developed to provide a simple and reliable solution to the demands of todays fire detection solutions. The Horizon range has been designed with both installer and end users requirements in mind. For installers Horizon offers an out of the box and on the wall solution.A combination of quick installation an enhanced feature set and advanced programming allows installers to meet the demands of the user quickly and simply. Equipped with configurable class change inputs coincidence detection programmable delays to allow alarm verification and the facility to interface to larger house alarm systems.For end users clear visible indications easy to operate functions and a big red key to activate the control buttons make for simple and unambiguous operation. Engineered and built to the same high standard as all Morley-IAS control panels the Horizon system forms an essential part of any fire alarm solution.The Horizon series of conventional control panels has been designed for use in small to medium commercial environments. It is especially suitable for Garages Retail Units Shops Restaurants Doctors Surgeries Public Offices and Nursery Schools.Key FeaturesSimple user friendly designSimple to installIntuitive to use2 4 or 8 ZonesWalk testEnhanced feature setMultilingual text insertsDesigned to comply with EN54 part 2 and part 4

GBP 302.26
1

Morley FS20X-211-24-6 Stainless Steel IR2 UV Zone 1 Flame Detector

Morley FS20X-211-24-6 Stainless Steel IR2 UV Zone 1 Flame Detector

Morley FS20X-211-24-6 Stainless Steel IR2 UV Zone 1 Flame DetectorBased on the foundation of the highly successful and reliable SS4 detector the FS20X detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X is a Multi-Spectrum and UVDual IRVIS fire and flame detector with a proven UV solar-blind sensor. The FS20X exhibits faster false-alarm free response to fires over a wider temperature range and with a much longer detection range compared to conventional UVIR detectors. Conventional and older technology UVIR detectors using narrow band 4.3 micron IR sensors will not respond to smokyfires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated obscured or absorbed by thick smoke or detector lens contaminations. All UV sensors will be attenuated to some degree. Also these old technology UVIR detectors will not alarm to any fire if they are installed behind ordinary window glass.The FS20 detector using advanced patented algorithms for signal processing and fire and flame analysis is designed to alarm to all types of fires in all industrial environmental conditions. If the detectors UV signal is degraded due to heavy smoke or a contaminated lens the FS20Xs patented WideBand IR Near Band IR and Visible sensors will still alarm to fire albeit at a reduced sensitivity and slower response time.Key FeaturesPatented WideBand IR Infrared combined with UltravioletDetection range greater than 60 m 200 feet to 0.1 m2 1 sq. ft. heptane firePatented Electronic Frequency AnalysisVisible sensor for optimum false alarm rejectionSelectable detection sensitivitiesSolar blind 90 cone-of-visionDual microprocessors for reliable performanceReal-time clock for accurate time dating of eventsFirePic Up to 6 pre-fire event data storageEvent log Up to 200 events with date and time stampBuilt-in RS-485 ModBus communicationBuilt-in non-isolated 4-20 mA analog output sink or sourceAlarm Fault and Fire Verification relaysAutomatic Optical Path and Electronic self-testPatented Electronics Module for component protection with plug-in terminations for easy field installationTwo 25 mm conduit entries or two NPTLow power consumptionHigh RFI and EMI immunityFM hazardous area approvedEx d ATEX approvedCU-TR approvedINMETRO approvedMeets SIL 2 requirementsCertified to EN54-102002 optionFM 3260 performanceApplicationsRefineries and oil production facilitiesOff-Shore platformsTurbineCompressor enclosuresAcetylene processing and storageOil and Gas pipelines and pumping stationsLNGLPG loading and unloading facilitiesNatural Gas and CNG plantsEthanol Methanol and IPA production and storageCrude oil and gasoline storage and tank farmsAircraft hangarsHydrogen plants and storagePaint and solvent storageChemical production storage and loading facilitiesPower plantsSilane gas storage

GBP 3434.89
1

Morley 721-001-200 ZX5Se Addressable 1-5 Loop Control Panel 200 Zone LEDs Multi-Protocol

Morley 721-001-200 ZX5Se Addressable 1-5 Loop Control Panel 200 Zone LEDs Multi-Protocol

Morley 721-001-200 ZX5Se Addressable 1-5 Loop Control Panel 200 Zone LEDs Multi-ProtocolOrder loop cards for the ZX5Se panel separately. Please scroll down to see options below.The ZX5Se range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed

GBP 4959.26
1

Morley 721-001-140 ZX5Se Addressable 1-5 Loop Control Panel 140 Zone LEDs Multi-Protocol

Morley 721-001-140 ZX5Se Addressable 1-5 Loop Control Panel 140 Zone LEDs Multi-Protocol

Morley 721-001-140 ZX5Se Addressable 1-5 Loop Control Panel 140 Zone LEDs Multi-ProtocolOrder loop cards for the ZX5Se panel separately. Please scroll down to see options below.The ZX5Se range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed

GBP 4290.05
1

Morley M210EA-CZR Analogue Addressable Monitor Module

Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Multi-Protocol

Morley DXc2 Addressable 2 Loop Fire Alarm Control Panel Morley-IAS Protocol

Morley DXc2 2 Loop Addressable Control Panel Multi-Protocol

Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Morley-IAS Protocol

Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Multi-Protocol

Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Morley-IAS Protocol

Morley MA-8000-01 Morley-IAS Max four Loop expandable to eight networkable For System Sensor amp Apollo protocol

Morley MA-8000-01 Morley-IAS Max four Loop expandable to eight networkable For System Sensor amp Apollo protocol

Morley MA-8000-01Morley-IAS Max fourloop expandable to eight networkable For System Sensor Apollo protocolMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 1772.89
1

Morley MA-2000-01 Morley-IAS Max 2 Loop

Morley MA-2000-01 Morley-IAS Max 2 Loop

Morley MA-2000-01 Morley-IAS Max 2 LoopMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 1102.98
1

Morley MA-1000-01 Morley-IAS Max Single Loop Non-Networkable For System Sensor amp Apollo

Morley MA-1000-01 Morley-IAS Max Single Loop Non-Networkable For System Sensor amp Apollo

Morley MA-1000-01 Morley-IAS Max Single Loop Non-Networkable For System Sensor ApolloMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 826.88
1