Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

229 results (0,19467 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier UT232R-200 USB to RS232 UploadDownload Lead - Windows 10

Notifier Honeywell Digital call station UIM multimode FO converter to DCS or UIM 583317.21

Notifier ECO Photoelectric Smoke Temperature Detector ECO1002A

Notifier Honeywell DKM Plus 18 Button Digital Key Module 583526

Notifier SMART4 White Intelligent Multi-Criteria Detector

Notifier SMART4 White Intelligent Multi-Criteria Detector

Notifier SMART4 White Intelligent Multi-Criteria DetectorFires take many forms from a slow smouldering fire that produces large amounts of smoke and Carbon Monoxide but little heat through to alcohol fires that produce high temperatures very quickly without any evidence of smoke.The SMART4 has a sophisticated brain capable of intelligently combining the data from the four sensing elements to provide a fast response to real fires while remaining extremely resilient to false alarm incidents. Using a combination of Carbon Monoxide Heat Optical smoke sensing and Infrared flame sensing elements enables SMART4 to detect the broadest range of fire conditions providing the earliest warning.How the SMART4 worksThe SMART4 is configured so that it normally operates at a high immunity level changing to become very sensitive to fires when fire characteristics are sensed. In this way transient nuisances are monitored and ignored reducing the false alarm rate.SMART4 dynamically adjusts the detection profile of the device in response to the input from the sensors enabling it to be re-characterised on the fly as the ambient conditions change. Based upon the sensor signals sensor thresholds sensor gain time delays combination sampling rates averaging rates are dynamically adjusted. And if any sensor fails the sensitivity of the remaining sensors are adjusted to compensate and a fault condition is indicated.The IR light sensor helps the detector recognise specific situations such as welding and makes adjustments rapidly in order to further reduce the potential for false alarms. The thermal detection function fuses thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities are likely to create unwanted alarms the detector can be programmed to operate on a Heat only mode automatically reverting to multi sensor operation during the unoccupied period. The SMART4 is thus able to offer exceptional false alarm immunity and excellent fire detection.Key FeaturesUnique true four sensor Multi-criteria detectorFully integrated Infra-Red sensor to support the fire alarm decisionCO gas sensing for fastest response to slow developing and smouldering firesHighest possible immunity to unwanted alarmsAutomatic drift compensation of smoke sensor and CO cellTwin LED indicators providing 360 visibilityWide temperature rangeBuilt in test switchStable communication with high noise immunity

GBP 212.53
1

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control PanelThe Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdS

GBP 2933.30
1

Notifier 011145F UNP Bi-Directional Paging Relay for Analog System Connectivity

Notifier 011145F UNP Bi-Directional Paging Relay for Analog System Connectivity

Notifier 011145F UNP Bi-Directional Paging Relay for Analog System ConnectivityThe 011145F UNP Paging Relay from Syn-Apps is a small PoE network appliance providing many features including unicast-to-multicast conversion that can eliminate bandwidth-intensive unicast streams across WAN connections. The Paging Relay enables fire alarm control panels analog PA systems analog security systems physical contacts and more to integrate seamlessly with the Honeywell UNP Unified Notification Platform.Paging Relay OperationThis patented product allows UNP notifications sent in multicast format to be converted to unicast for multi-site WAN-connected voice networks. The Paging Relay converts incoming streams back to multi-cast at the destination site used for delivery to the following appropriate end-pointsIP phonesIP speakersTraditional PA Systems-via analog audio via RCA or 600 ohm interfacesThe 011145F Paging Relay is small enough to hold in one hand and features plug-n-play technology making installation as simple as connecting an Ethernet cable to a device.Key FeaturesEasily integrates the fire alarm control panels with Honeywell UNP to activate notificationsUnicast-to-multicast conversionAuto registration to Honeywell UNP via DHCPUp to 8MB on-board storage used for audio files or stored announcements600 ohm and RCA line-out ports for overhead paging and analog systemsProvides RCA analog audio input used for Background Music and Music On-Hold MOHContains a SIP interface that allows SRSTCME fail-over support for the enhanced redundancySends trigger notifications when activated via the Sense-In portContains a Web-based interface for customization and software upgradesRelay and Sensor Contact Closure functionality Automatically plays audio files control door and window entries activates sirensstrobes and moreAccepts commands from 3rd party systems to activate locally stored audio to play reducing bandwidth consumption in WAN deploymentsGain control for integration with external audio input devices V4 unitsStream analog audio to IP Multicast for background music when integrated with the Honeywell UNPAutomatic GatingZone PagingSupports up to 10 simultaneous broadcastsLocal authentication servicesNight Ringer FunctionalityDirect Cisco ICM integration

GBP 2547.98
1

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.RE

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.RE

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.REIn many installation codes it is necessary to have redundancy in critical signal routes like speaker cables Loop or AB cabling between fire panel and the PAVA system. In some installation codes this includes also the connection to the fire men paging microphone.For very good reason because if the connection to the call station is lost there is no way for any live announcement to people which are potential or actually in high danger. Our paging station also supports redundant cable connection to two separate Comprio not standalone Version of Comprio or DOMs which means its possible to connect two cables CAT5 to one paging station. The digital paging microphone DCSF12 serves for the selection of loudspeaker circuits and for setting off speech announcements as well as various gong or alarm sounds.It features 12 freely configurable keys 13 LED and a handheld microphone. The paging microphone is connected with our DAL Digital Audio Link bus to a Comprio or DOM by means of a standard CAT5 cable. All audio signals and all control signals are transmitted digitally. The function of the digital paging microphone is permanently acoustically monitored. Up to four DAL bus links can be connected to a DOM.Every digital call station in the system can simultaneously generate and receive different voice transmissions and control signals. A digital paging microphone can be offset up to 300 m by means of a CAT5 cable. Extension to a greater distance is possible with fiber optic FO cables - see respective FO converters which are needed additionally. Also a connection with FO cables can be done redundant. If more keys andor LEDs are needed it is possible to add up to six digital key modules DKM18 which allows the increase of the total number of available keys and LEDs to 120 per call station.Key FeaturesHigh failure safety due to redundant transmission routeHand-held microphone with built-in loudspeaker and acoustic microphone monitoringPermanent monitoring of the line to the next interface module24-bit ADDA converter12 freely configurable keysAdditional LED programmable in yellow or redCan be used redundantly as well as non- redundantly

GBP 2068.56
1

Notifier SMART4 Ivory Intelligent Multi-Criteria Detector

Notifier SMART4 Ivory Intelligent Multi-Criteria Detector

Notifier SMART4 Ivory Intelligent Multi-Criteria DetectorThe SMART4 combines 4 separate sensing elements to act as a single unit. CO sensing using EC technology for monitoring CO products from a smouldering fire IR sensing for measuring ambient light levels and flame signatures optical smoke detection and heat detection. The integration of continual monitoring for all four major elements of a fire has enabled us to create a detector that responds far more quickly to an actual fire and has the highest immunity to nuisances. The operating philosophy behind SMART4 was to configure it so that it normally operates at a high immunity level changing to become very sensitive to fires when fire characteristics are sensed. In this way transient nuisances are monitored and ignored reducing the false alarm rate.SMART4 is managed by on-board intelligence running some very advanced algorithms which dynamically adjust the detection profile of the device in response to the input from the sensors enabling it to be re-characterised on the fly as the ambient conditions change. Based upon the sensor signals the program is dynamically changing sensor thresholds changing sensor gain changing time delays changing combination changing sampling rates changing averaging rates and if any sensor fails changing sensitivity of the remaining sensors as well as indicating a fault condition.The IR light sensor helps the detector recognise specific situations such as welding and makes adjustments rapidly in order to further reduce the potential for false alarms caused by nuisances. The thermal detection function fuses thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities are likely to create unwanted alarms the detector can be programmed to operate on a Heat only mode automatically reverting to multi sensor operation during the unoccupied period. The SMART4 is thus able to offer exceptional false alarm immunity and excellent fire detection.

GBP 324.48
1

Notifier Honeywell ABT-NSMA Noise Sensing Microphone

Notifier Honeywell ABT-NSMB Noise Sensing Microphone

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520The digital call station DCS plus allow the selection of loudspeaker circuits the transmission of voice announcements as well as various gongs and alarms. The digital call station is connectable via a standard CAT5 cable to the VARIODYN D1 control devices DOM and Comprio. All control signals up to four simultaneous audio signals and the power supply are transmitted. This connection can be done by single or redundant cabling up to 300 m away.It can be increased to 20 Kilometers by using fiber-optic cabling. The digital call station DCS plus can be expanded with up to six digital keyboard modules DKM plus whereby the total number of available keys and LEDs increases to 120 per communication station. The function of the microphone and the cable connection is permanently monitored. The DCS plus provides an additional external audio input and output which can be used to connect audio devices such as CD players. A 3 m long CAT5 cable to connect the digital call station to a wall jack is included.Key FeaturesHigh failure safety due to redundant transmission routeCost-effective CAT5 cablingElectret gooseneck microphone with cardioid patternExchangeable gooseneck microphone with protection by using a specific tool to lockunlockPermanent monitoring of the microphone and cableMechanical protection against cable disconnectionBuild-in loudspeaker for monitoring and for intercom operation between other paging stationsIndependent additional audio inputoutput e.g. for audio player12 freely configurable keys with independent programmable LEDs

GBP 1928.22
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Includes1 x 020-538 - Basic Equipment kit 2-8 Loops1 x 020-579 - 7A PSU 4.5A or 7A User selectable1 x 020-543- Dual transmittion path board kit1 x 020-588 - Dual loop board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-485-009 - Extension cover blanking kit1 x 020-481-009 - Extension cover kit

GBP 4722.00
1

Notifier NFXI-SMT2 Analogue Addressable Optical amp Thermal Multi Detector - Black

Notifier NFXI-SMT2 Analogue Addressable Optical amp Thermal Multi Detector - Black

Notifier NFXI-SMT2 Analogue Addressable Optical Thermal Multi Detector - BlackThe Opal multi-criteria multi-sensor photo thermal detector uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fires. The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit.The Opal NFXI-SMT2 conforms to EN54-7 a 58C fixed temperature and rate of rise thermal assistance conforming to EN54-5. The thermal detection function combines thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities may potentially create unwanted alarms the detector can be programmed to operate in a heat only mode automatically reverting to full photo-thermal operation during unoccupied periods.The sensing elements of the Opal NFXI-SMT2 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 107.08
1

Notifier NFX-SMT2-IV Optical amp Thermal Multi Detector - Ivory

Notifier NFX-SMT2-IV Optical amp Thermal Multi Detector - Ivory

Notifier NFX-SMT2 Optical Thermal Multi Detector - IvoryThe Opal multi-criteria multi-sensor photo thermal detector uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fi res. The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit. The Opal NFXI-SMT2 conforms to EN54-7 a 58C fixed temperature and rate of rise thermal assistance conforming to EN54-5.The thermal detection function combines thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities may potentially create unwanted alarms the detector can be programmed to operate in a heat only mode automatically reverting to full photo-thermal operation during unoccupied periods.The sensing elements of the Opal NFXI-SMT2 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 129.79
1

Notifier NFXI-SMT2 Optical amp Thermal Multi Detector - White

Notifier NFXI-SMT2 Optical amp Thermal Multi Detector - White

Notifier NFXI-SMT2 Optical Thermal Multi DetectorThe Opal multi-criteria multi-sensor photo thermal detector uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fires. The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit.The Opal NFXI-SMT2 conforms to EN54-7 a 58C fixed temperature and rate of rise thermal assistance conforming to EN54-5. The thermal detection function combines thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities may potentially create unwanted alarms the detector can be programmed to operate in a heat only mode automatically reverting to full photo-thermal operation during unoccupied periods.The sensing elements of the Opal NFXI-SMT2 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 69.77
1

Notifier Honeywell ABT-DFMS Fireman Microphone

Notifier NFX-MM1M Addressable Mini Monitor input module

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops3 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1x 020-548 - Optional status indicator board kit for 7A PSU1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H620mm W500mm D122mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer1 x 020-541-009 - 7A PSU78AH battery cabinet kit

GBP 6122.94
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops1 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable1 x 020-543 - Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 4599.50
1

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops2 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kitspace for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 5150.30
1

Notifier Local Silence Button Assembly Includes Wiring Loom NF-SIL-B

Notifier Local Silence Button Assembly Includes Wiring Loom NF-SIL-B

Notifier Advanced Alarm Management Notifier Local Silence Button Assembly Includes Wiring Loom NF-SIL-BThe NOTIFIER Local Silence Button in conjunction with the advanced programming provided by the Pearl control panel enables the use of a full BS5839 Part 1 system in applications such as assisted living retirement homes student accommodation high rise residential buildings. Often the risk of false alarm in such buildings has led to these sorts of installation being provided with individual systems for the flats linked to a landlord system for the shared area.The local silence button is a multi-position switch that allows not only sounder test and silencing but also disablement of smoke detection and the indication of disablement. As with other features it is flexible in configuration so that the facilities may be tailored to suit each site.FeaturesBest detection throughout. Allows Opal multi criteria detectors to reduce false alarms.Fully configurable. Allowing the installer to design delay periods and response times on all parts of the system in order to ensure it meets your building requirements.Flexible and simple to install. The Local Silence Button is available in a kit including wiring loom and loop moduleSupporting compliance. BS5839 Part 6 requires the alarm in each dwelling to be tested on a regular basis. This activity is logged on the Pearl system allowing landlords to check the residents are performing this task ensuring fire safety and compliance.

GBP 113.57
1