Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

22 results (0,12793 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier Honeywell ABT-DMS Zone Microphone

Notifier NFS 8 Zone Conventional Fire Alarm Panel

Notifier NFS 2 Zone Conventional Fire Alarm Panel

Notifier NFS 4 Zone Conventional Fire Alarm Panel

Notifier NFS3-EXT Single Area 3 Zone Extinguishant Control Panel

Notifier 719782-2430 Bose FreeSpace IZA 2120-HZ Integrated Zone Amplifier

Notifier 719782-2430 Bose FreeSpace IZA 2120-HZ Integrated Zone Amplifier

Notifier 719782-2430 Bose FreeSpace IZA 2120-HZ Integrated Zone AmplifierFor backgroundforeground music and paging applications Bose Professional FreeSpace IZA 2120-HZ integrated zone amplifier elevates the audio experience when using FreeSpace loudspeakers.Optimised for commercial applications FreeSpace IZA amplifiers feature selectable Loudspeaker EQ to enrich audio quality Opti-Voice paging for clear speech intelligibility while providing seamless transitions and Dynamic EQ that ensures full and balanced music at any volume level.Key FeaturesTrue two-zone capability provides two independent outputs that each support volumesource selection remotes EQ tone controls and pagingauxiliary routing optionsOpti-Voice paging equalizes the vocal frequency range for clear speech intelligibility while providing seamless transitionsDynamic EQ ensures full and balanced music at any volume levelIndependent Loudspeaker EQ per output enriches audio quality and simplifies connection to Bose Professional loudspeakers FreeSpace 3 systems FS3B subwoofer FS2CSEP FS4CESE and the DesignMax DM2C-LPSDual remotes support optional volumesource selection for independent or combined zone control which eliminates the need for bulky inefficient and sound-altering 70100V in-line volume controlsReliable 2 x 120 W Class-D amplification optimized for 70100V high-impedance applicationsIntuitive feature setup enables the amplifier to be configured without a PC for remote paging auxiliary inputoutput and automatic standby optionsAuto-Standby feature allows the amplifier to consume less power when not in useSimplified front panel interface provides end users with tone source selection and master volume controls as well as a connection to mobile sources via a 3.5 mm connectorRemote muting allows the amplifier to be muted via a centralised control system

GBP 2232.47
1

Notifier Honeywell ABT-DMS-LCD Zone Microphone with LCD

Notifier 719782-2440 Bose FreeSpace IZA 2120-LZ Integrated Zone Amplifier

Notifier 719782-2440 Bose FreeSpace IZA 2120-LZ Integrated Zone Amplifier

Notifier 719782-2440 Bose FreeSpace IZA 2120-LZ Integrated Zone AmplifierFor backgroundforeground music and paging applications Bose Professional FreeSpace IZA 2120-LZ integrated zone amplifier elevates the audio experience when using FreeSpace loudspeakers.Optimised for commercial applications FreeSpace IZA amplifiers feature selectable Loudspeaker EQ to enrich audio quality Opti-Voice paging for clear speech intelligibility while providing seamless transitions and Dynamic EQ that ensures full and balanced music at any volume level.Key FeaturesOpti-Voice paging equalizes the vocal frequency range for clear speech intelligibility while providing seamless transitionsDynamic EQ ensures full and balanced music at any volume levelLoudspeaker EQ enriches audio quality and simplifies connection to Bose Professional loudspeakers FreeSpace FS2CSEP FS4CESE and DesignMax DM2C-LPS DM3CSERemote option for volumesource selection eliminates the need for bulky inefficient and sound-altering in-line volume controlsReliable 2 x 120 W Class-D amplification optimized for low-impedance applicationsIntuitive feature setup enables the amplifier to be configured without a PC for output remote paging auxiliary inputoutput and automatic standby optionsAuto-Standby feature allows the amplifier to consume less power when not in useSimplified front panel interface provides end users with tone source selection and master volume controls as well as a connection to mobile sources via a 3.5 mm connectorRemote muting allows the amplifier to be muted via a centralized control system

GBP 2006.44
1

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops2 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kitspace for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 5150.30
1

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops3 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1x 020-548 - Optional status indicator board kit for 7A PSU1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H620mm W500mm D122mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer1 x 020-541-009 - 7A PSU78AH battery cabinet kit

GBP 6122.94
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops1 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable1 x 020-543 - Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 4599.50
1

Notifier NFX-MM1M Addressable Mini Monitor input module

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKITThe NOTIFIER Local Silence Button in conjunction with the advanced programmingprovided by the Pearl control panel enables the use of a full BS5839 Part 1 system inapplications such as assisted living retirement homes student accommodation highrise residential buildings. Often the risk of false alarm in such buildings has led to thesesorts of installation being provided with individual systems for the flats linked to alandlord system for the shared area.The use of the NOTIFIER local silence button and Type-B dependency programmingnow enables full BS 5839 Part 1 systems to be installed in all areas.Type B DependencyType B dependency allows a zone to be defined for each individual flat that acts as ifit were a separate system. On receipt of an unconfirmed fire signal from a flat onlythe local alarm within the flat is given. If the alarm is confirmed by a second signal thesystem proceeds to the relevant evacuation stage general alarm or part of stagedevacuation. Alternatively if the confirmation signal is not given the system may resetautomatically without attendance by facility management staff.Local Silence ButtonThe local silence button is a multi-position switch that allows not only sounder test andsilencing but also disablement of smoke detection and the indication of disablement. Aswith other features it is flexible in configuration so that the facilities may be tailored tosuit each site.NOTIFIER NF-SIL-BKIT LOCAL SILENCE BUTTON KIT FEATURESBest detection throughout. AllowsOpal multi criteria detectors to reducefalse alarms.Fully configurable. Allowing theinstaller to design delay periods andresponse times on all parts of thesystem in order to ensure it meetsyour building requirements.Flexible and simple to install. TheLocal Silence Button is available in a kitincluding wiring loom and loop moduleSupporting compliance. BS5839 Part6 requires the alarm in each dwellingto be tested on a regular basis. Thisactivity is logged on the Pearl systemallowing landlords to check theresidents are performing this taskensuring fire safety and compliance.Local Silence of an AlarmThe user is able to silence the local sounder or sounder beacons within their premisesby pressing the Fire Alarm Silence button when a detector has activated within theirpremises. When the site is in a full evacuation mode this feature is disabled and thelocal sounder or sounder beacons cannot be silenced by the user.Local DisablementIf the user believes that they may generate an unwanted alarm from a smoke detectorwithin their premises they can press and hold the Fire Alarm Silence button for 5seconds. The yellow LED illuminates which will then disable the detection in that zoneonly for a configurable period of between 5-15 minutes in accordance with BS5839 Part 6.At the end of the configured period the zone will automatically re-enable all detectionwill be active and the LED will be extinguished.Local TestA test feature is available which allows the user to operate the sounder or sounderbeacons within the local zone by pressing and holding down the Fire Alarm Testbutton once released the sounder or sounder beacons will silence.ConnectionThe button is connected to the Pearl loop via a Notifier 21 dual input single outputinterface unit and a 5-core cable.

GBP 287.16
1

Notifier NFS-10LU 10 Lamp Extinguishant Control Repeater

Notifier Honeywell ABT-DFMS Fireman Microphone