Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

82 results (0,15469 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

SAS NET208 Infrared Call Transmitter For Use With NET207 Range

SAS Caring Technology Touch-Curo-Key-PIR Touch Curo Key for Bed PIR

SAS Caring Technology Touch-Curo-Key-CPS Touch Curo Key For Cronapress Strip

SAS NET218 Door Monitoring Unit with Key Switch for Isolation Reset

SAS Caring Technology Touch-Curo-Key-RU Touch Curo Key for Room Unit

SAS Caring Technology Touch-Curo-Key-RU Touch Curo Key for Room Unit

SAS Caring Technology Touch-Curo-Key-RU Touch Curo Key for Room UnitDesigned for challenging environments. The staff reset unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The staff reset unit is situated near a monitored door at hip height and. Under normal operation if the door is opened the SRU triggers an elevated call ALARM it is then reset by the Curo at very close range.Touching the Curo on the depicted graphic will reset the alarm. The SRU can be dis-armed to ignore the door state by manually touching the Curo on the graphic this mode is commonly used through the day. The LED will acknowledge with a brief white colour followed by a blue flash. To return the SRU to normal operation touch the Curo on the graphic there will be a white acknowledge followed by a red flash. Whenever the SRU is set there will be a brief period where the door state will be ignored this is engineer adjustable and if set to zero there will be no delay to ARMED. During the delay to arm a relay output closes which could be used as an electronic lock release. Note there is no means to reset device by emergency services so a break-glass unit must be used. The staff reset unit is addressable and its 20-character name is programmed by infrared only.Available with an optional buzzer if greater audibility is needed. Included 2x torx M3.5 x 25mm security screws. Note Curo refers to the staff alarm fob personal alarm transmitter.Key FeaturesFascia 95mm x 95mm x 5.4mmBack box Single gang depth 25mm recommendedLED RGBWeight with back box 78g 250gSupply current 2.5mA inactive 38mA activeNetwork R B and YTemperature 0-50C

GBP 186.30
1

SAS Caring Technology Touch-Curo-Key-DM Touch Curo Key for Door Monitor - With ArmDisarm Functions

SAS Caring Technology Touch-Curo-Key-DM Touch Curo Key for Door Monitor - With ArmDisarm Functions

SAS Caring Technology Touch-Curo-Key-DM Touch Curo Key for Door Monitor - With ArmDisarm FunctionsDesigned for challenging environments. The staff reset unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The staff reset unit is situated near a monitored door at hip height and. Under normal operation if the door is opened the SRU triggers an elevated call ALARM it is then reset by the Curo at very close range. Touching the Curo on the depicted graphic will reset the alarm. The SRU can be dis-armed to ignore the door state by manually touching the Curo on the graphic this mode is commonly used through the day. The LED will acknowledge with a brief white colour followed by a blue flash. To return the SRU to normal operation touch the Curo on the graphic there will be a white acknowledge followed by a red flash. Whenever the SRU is set there will be a brief period where the door state will be ignored this is engineer adjustable and if set to zero there will be no delay to ARMED. During the delay to arm a relay output closes which could be used as an electronic lock release. Note there is no means to reset device by emergency services so a break-glass unit must be used. The staff reset unit is addressable and its 20-character name is programmed by infrared only. Available with an optional buzzer if greater audibility is needed. Included 2x torx M3.5 x 25mm security screws. Note Curo refers to the staff alarm fob personal alarm transmitter.Key FeaturesFascia 95mm x 95mm x 5.4mmBack box Single gang depth 25mm recommendedLED RGBWeight with back box 78g 250gSupply current 2.5mA inactive 38mA activeNetwork R B and YTemperature 0-50C

GBP 186.30
1

SAS Caring Technology Touch-Eye-EXL Touch External Infrared Sensor

SAS RED255 External Infrared Receiver

SAS Caring Technology Touch-Eye-EXL-AL Touch External Infrared Sensor With Metal Anti Lig Collar - BOX 36

SAS Caring Technology Touch-Display-Network-SF Vandal Resistant Display and Sounder