Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

26 results (0,16062 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

SAS RED2092 Single Reset Infrared Unit

SAS RED2081 Single Alarm Infrared Unit

SAS Caring Technology Touch-Hub-RED System Hub And Power Supply Unit - Staff Attack

SAS Caring Technology Touch-Curo-Key-PIR Touch Curo Key for Bed PIR

SAS Caring Technology Touch-Display-Network-FL Flush Touch LCD Text Indicator Panel

SAS Caring Technology Touch-Display-RedAlert-FL Flush Touch LCD Text Indicator Panel

SAS Caring Technology Touch-Curo-Key-CPS Touch Curo Key For Cronapress Strip

SAS Caring Technology Touch-Curo-Key-SR Touch Curo Key Unit To Operate Swing Rooms

SAS Caring Technology Touch-Eye-IS IR Reset Only Receive Alarm Level Contacts Doortop Intastop

SAS Caring Technology Touch-ODL-NA Non-Addressable Touch Over Door Light - NO Contact Only

SAS Caring Technology Touch-DISP-ODL-RS Display Over Door Light With Relay amp Sounder

SAS Touch-Hub-NET System Control Hub and Power Supply

SAS TouchPearPush Pear Push Lead CW Straight Jack Plug - Orange - RAL 2000

SAS Caring Technology Touch-Curo-Key-DM Touch Curo Key for Door Monitor - With ArmDisarm Functions

SAS Caring Technology Touch-Curo-Key-DM Touch Curo Key for Door Monitor - With ArmDisarm Functions

SAS Caring Technology Touch-Curo-Key-DM Touch Curo Key for Door Monitor - With ArmDisarm FunctionsDesigned for challenging environments. The staff reset unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The staff reset unit is situated near a monitored door at hip height and. Under normal operation if the door is opened the SRU triggers an elevated call ALARM it is then reset by the Curo at very close range. Touching the Curo on the depicted graphic will reset the alarm. The SRU can be dis-armed to ignore the door state by manually touching the Curo on the graphic this mode is commonly used through the day. The LED will acknowledge with a brief white colour followed by a blue flash. To return the SRU to normal operation touch the Curo on the graphic there will be a white acknowledge followed by a red flash. Whenever the SRU is set there will be a brief period where the door state will be ignored this is engineer adjustable and if set to zero there will be no delay to ARMED. During the delay to arm a relay output closes which could be used as an electronic lock release. Note there is no means to reset device by emergency services so a break-glass unit must be used. The staff reset unit is addressable and its 20-character name is programmed by infrared only. Available with an optional buzzer if greater audibility is needed. Included 2x torx M3.5 x 25mm security screws. Note Curo refers to the staff alarm fob personal alarm transmitter.Key FeaturesFascia 95mm x 95mm x 5.4mmBack box Single gang depth 25mm recommendedLED RGBWeight with back box 78g 250gSupply current 2.5mA inactive 38mA activeNetwork R B and YTemperature 0-50C

GBP 186.30
1

SAS Caring Technology Touch-Curo-Key-RU Touch Curo Key for Room Unit

SAS Caring Technology Touch-Curo-Key-RU Touch Curo Key for Room Unit

SAS Caring Technology Touch-Curo-Key-RU Touch Curo Key for Room UnitDesigned for challenging environments. The staff reset unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The staff reset unit is situated near a monitored door at hip height and. Under normal operation if the door is opened the SRU triggers an elevated call ALARM it is then reset by the Curo at very close range.Touching the Curo on the depicted graphic will reset the alarm. The SRU can be dis-armed to ignore the door state by manually touching the Curo on the graphic this mode is commonly used through the day. The LED will acknowledge with a brief white colour followed by a blue flash. To return the SRU to normal operation touch the Curo on the graphic there will be a white acknowledge followed by a red flash. Whenever the SRU is set there will be a brief period where the door state will be ignored this is engineer adjustable and if set to zero there will be no delay to ARMED. During the delay to arm a relay output closes which could be used as an electronic lock release. Note there is no means to reset device by emergency services so a break-glass unit must be used. The staff reset unit is addressable and its 20-character name is programmed by infrared only.Available with an optional buzzer if greater audibility is needed. Included 2x torx M3.5 x 25mm security screws. Note Curo refers to the staff alarm fob personal alarm transmitter.Key FeaturesFascia 95mm x 95mm x 5.4mmBack box Single gang depth 25mm recommendedLED RGBWeight with back box 78g 250gSupply current 2.5mA inactive 38mA activeNetwork R B and YTemperature 0-50C

GBP 186.30
1

SAS Caring Technology Touch-PB-ATT Panic Button Alarm Level

SAS Caring Technology Touch-PB Panic Button Alarm Level

SAS RED205 Infrared Receiver Ceiling Mounted

SAS NET204M Remote Input Call Point Alarm Call Facility Push Button Reset

SAS RED234 Datastore Software Package with RS232 Port with 3m Lead

SAS NET234 Data Store Software

SAS NET205M Patient Call Unit with Alarm amp Crash Call Facilities Push Button Reset

SAS NET205MPC Net205M with Pull Cord

SAS RED2086RF Radio Curo Alarm Unit