Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

2 results (0,14059 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vent-Axia Lo-Carbon Heat Save

Vent-Axia Lo-Carbon Heat Save

Vent-Axia Lo-Carbon Heat Save Product Part Number Vent-Axia Lo-Carbon Heat Save - 496036 Vent-Axia Wired Zone Control Panel - 496037 Description Through-The-Wall Heat recovery Unit The Vent-Axia Lo-Carbon Heat Save is a ventilation unit designed for living rooms and bedrooms in single and multi-family buildings. The unit is usually located in an exterior wall to provide new air to the room. The Vent-Axia Lo-Carbon Heat Save uses a reversible fan to extract dirty air from the room and replace it with outside air 70 seconds later. This air passes through a filter to ensure that clean air enters the room. These systems work best in pairs as when one unit is extracting, the other can be supplying air to provide a balanced ventilation system. They are controlled by a SENWZP Sentinel wired zone controller which can operate up to 8 units in synchronization. This provides a single room or whole house balanced ventilation system with heat recovery. As well as filtering the air, the Vent-Axia Lo-Carbon Heat Save uses a thermal accumulator to extract warmth from the outgoing air and uses it to temper the incoming air to avoid the feeling of cold drafts and recover heat that would otherwise be lost to the outside. Typical Installation The Vent-Axia Lo-Carbon Heat Save can be fitted in a 180mm diameter hole. Maximum wall thickness is 460mm or 745mm with optional wall tube (see accessories). The wall sleeve length (included up to 460mm) can be cut down to size to fit any wall thickness. Vent-Axia Lo-Carbon Heat Save units work best in pairs. When one unit is extracting, the other can be supplying air to provide a balanced ventilation system. They alternate direction every 70 seconds when the thermal accumulator on the extract unit has warmed up allowing the supply air to benefit from these thermal gains. They are controlled by a SENWZP Sentinel wired zone controller. This is fully modular and controllable with customized ventilation profiles available so that every room in the home can have the perfect ventilation.

GBP 413.62
1

Vent Axia Lo-Carbon Sentinel Kinetic Cooker Hood

Vent Axia Lo-Carbon Sentinel Kinetic Cooker Hood

Vent Axia Sentinel Kinetic heat recovery unit with Cooker Hood Product Part Number Vent Axia Kinetic CWH L (White Cooker Hood) - 446756 Description The Sentinel Kinetic Cooker Hood is designed to fit in a 600mm wide aperture above a hob. The telescopic hood incorporates two flat removable metal grease filters, low energy light bulbs and is available with a White or Brushed Aluminium front trim. The hood contains an integral fire damper in accordance with BRE Digest 398 and is connected to the heat recovery unit by a galvanised steel duct with access for cleaning. When the hood is opened, the heat recovery unit goes to boost speed and the summer bypass automatically opens to prevent cooking by-products entering the heat recovery cell. As an additional safety feature, the duct also contains a thermal cut-out fuse which turns off the MVHR unit in the event of excessive temperature in the airway. Cooker Hood units cannot be handed on-site and must be purchased as left hand (L) or right hand (R) models. The Lo-Carbon Sentinel Kinetic BH is the UKs bestselling heat recovery unit for people looking for a top quality unit at a realistic cost. Suitable for houses up to 150 m2 and meets the latest requirements of the Building Regulations ADF and ADL for whole house system ventilation. Filtration 2 x G4 with the option of a F7 pollen intake filter Controllability The Lo-Carbon Sentinel Kinetic models have 3 fully adjustable speeds and a purge setting (maximum flow). Provided with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range Boost can be achieved with almost any type of sensor or switch including momentary  Integral Humidity Sensor The integral humidity sensor (models with H suffix) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature Construction The outer enclosure is constructed of PVC with the inner body being constructed of EPP Motors The unit has 2 x low energy, high efficiency EC/DC motors Installation Spigot Options The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after

GBP 2862.29
1