Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

40 results (0,15041 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis WHTFLXI25B 25mm Flexible 1m Long Bend

Vesda Xtralis M8 Nut - Pack of 10 PIP-029

Vesda Xtralis 25mm10mm Compression Adaptor Pack of 10

Vesda Xtralis WHTCTII0250-10 25mm10mm White Capillary Tee

Vesda Xtralis 25mm 2-Way Ball Valve

Vesda Xtralis 25mm In-line Expansion Socket 100mm PIP-019

Vesda Xtralis Discreet Clear End Cap for 10mm OD Tube Pack of 10

Vesda-E VEA VSP-990-330 6mm Microbore Tube UL-compliant Plenum-rated 330ft

Vesda-E VEA VSP-990-330 6mm Microbore Tube UL-compliant Plenum-rated 330ft

Vesda-E VEA VSP-990-330 6mm Microbore Tube UL-compliant Plenum-rated 330ftVESDA-E VEA microbore tubes are custom made high quality plenum rated flame retardant polyethylene tubes. They have superior stress crack resistance for reliable long-term performance. They are lightweight and flexible for easy handling and installation and marked with a white ink numbering system over the full length of the tubing. The numbering system includes individual unique identification of each tube and distance marking at regular intervals making them very efficient to install and keep clean installationrecords.These tubes come in black colour with red stripes for use in smoke detection and meet requirements of global installation codes. These tubes have no active components and they eliminate the need for any electrical wiring for smoke detection resulting in fast and easy installation without the need to follow electrical codes.It is important to use VESDA-E VEA microbore tubes with the VESDA-E VEA detectors to maintain their smoke detection performance. These tubes come in two different diameters 6mm and 4mm.VEA micrbore tube fittings comprise of straight unions and other types of joiners and 6mm to 4mm adaptors for easy installations blanking plugs are used to block the unused ports on VEA.Key FeaturesPlenum ratedFlame retardantHigh quality polyethylene materialStress crack resistantUnique IDDistance marking at regular intervalsMeets requirements of global installation codesListings ApprovalsUL 1820NFPA 90AEN 54-202006 clause 5.7BS EN 61386-12007 clauses 10.2 10.3 and 12.2

GBP 156.30
1

Vesda Xtralis 128-015 Smoke Detector Pipe Label - Pack of 100

Vesda Xtralis 059-007 Conical Sampling Point Kit

Vesda Xtralis 128-014-XTR Label Sampling Point Roll of 100

Vesda Xtralis PIP-001-2.4 Red ABS Pipe - 2.4m Length Pack of 25

Vesda-E VEA VSP-990-NYLON-BLK 6mm Microbore Nylon Black 100m

Vesda Xtralis PIP-014 Pipe Cutters

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 CoverageThe OSI-10 covers a distance of 30 - 150m with the OSE-SPW. This configuration is for a 1 on 1 system and is not suitable to work with high powered emitters.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.3D Volumetric CoverageA significant benefit of OSID is its ability to provide volumetric coverage. As many as seven emitters can be placed within the field of view of a single imager each placed at different heights. The OSID imagers large viewing angles both horizontal and vertical enable three-dimensional area coverage for design flexibility and additional deployment savings. Unlike other volumetric technologies OSID delivers absolute calibration for consistent detection performance regardless of lighting conditions smoke colour airflows or other environmental conditions.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floorsThe OSI-10 Imager must be paired with either the OSE-SP-01 or OSE-SPW Standard Power Emitter. The OSI-10 can only support one emitter.

GBP 671.33
1

Vesda VHX-1420 Metal Box HLI Modbus Type 3

Vesda VHX-1420 Metal Box HLI Modbus Type 3

Vesda VHX-1420 Metal Box HLI Modbus Type 3The VESDA Modbus Type 3 High Level Interface HLI integrates VESDAnet network with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Modbus Type 3 HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information that is available from VESDA detectors as well as the ability to control and configure these devices. Alarms are reported to the host within a few seconds of a detector reaching an alarm condition.Exact performance is dependent on the polling strategy and size of the monitored network. The Modbus Type 3 HLI is able to support up to 100 VESDA detectors on a single VESDAnet network. The wall-mounted version is housed in a metal enclosure allowing for permanent mounting on a flat surface. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module making the wall-mounted HLI a cost-effective solution to your interface requirements.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol SupportsVESDA VLP VLS VLC VLF VLI and VFT-15 detectorsVESDA-E VEP VEU and VEA detectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearn

GBP 2399.28
1

Vesda Xtralis 25mm Flexible 1m Long Bend

Vesda Xtralis 25mm Flexible 1m Long Bend

Vesda Xtralis 25mm Flexible 1m Long BendWith over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Always use tools specifically designed forplastic pipe.Protective gloves are recommended for usewhen solvent cementing. If hands come into contact with cement use a waterless abrasive soap.Avoid sources of heat or open flames when solvent cementing. Do not smoke.Always chamfer and deburr pipe ends.Use the proper solvent cement note air shipments of solvent cement are forbidden by law.Always replace lids on cans when not in use.Never dilute solvent cement.Keep jointing surfaces dry in wet weather.Avoid direct inhalation of fumes. Use in a well-ventilated area.Wipe up spills or leaks immediately with clean lint free cloth or paper towels.Follow recommended cure times prior to testing the system.Prevent excessive solvent cement from running into the pipe or fitting socket.The Integrity of air sampling systems may be affected if proper CPVC solvent cement is not used. The Safety Crewdisclaims responsibility for any air sampling pipe system constructed with cements other than those recommended.Please note The PIP-021 is equivalent to the REDFLXI25B.

GBP 24.38
1

Vesda Xtralis VHX-0320 PC Link HLI Access Protocol

Vesda Xtralis VHX-0320 PC Link HLI Access Protocol

Vesda Xtralis VHX-0320 PC Link HLI Access ProtocolThe VESDA Access High Level Interface HLI integrates VESDAnet networks with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Access HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information available from VESDA detectors as well as the ability to control and configure these devices.The Access HLI is able to report alarms to the host within a few seconds of a detector reaching an alarm condition. Exact performance is dependent on the polling strategy and size of the monitored network. The Access HLI is able to support up to 100 VESDA detectors on a single VESDAnet network. A standard unit used to provide a flexible solution where permanent mounting is not required. In this case a VESDAnet socket interface is required to connect the HLI onto the VESDAnet network.Key FeaturesDirect access and monitoring of your entire VESDAnet networkSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol Supports VESDA VLP VLS VLC VLF VLI and VFT-15 range of DetectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearnAsynchronous notification of the device state including alarm level detailed faults and current thresholds

GBP 1268.46
1

Vesda Xtralis REDFLEXI25B 25mm Flexible 1m Long Bend

Vesda Xtralis REDFLEXI25B 25mm Flexible 1m Long Bend

Vesda Xtralis REDFLEXI25B 25mm Flexible 1m Long BendWith over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Always use tools specifically designed forplastic pipe.Protective gloves are recommended for usewhen solvent cementing. If hands come into contact with cement use a waterless abrasive soap.Avoid sources of heat or open flames when solvent cementing. Do not smoke.Always chamfer and deburr pipe ends.Use the proper solvent cement note air shipments of solvent cement are forbidden by law.Always replace lids on cans when not in use.Never dilute solvent cement.Keep jointing surfaces dry in wet weather.Avoid direct inhalation of fumes. Use in a well-ventilated area.Wipe up spills or leaks immediately with clean lint free cloth or paper towels.Follow recommended cure times prior to testing the system.Prevent excessive solvent cement from running into the pipe or fitting socket.The Integrity of air sampling systems may be affected if proper CPVC solvent cement is not used. The Safety Crewdisclaims responsibility for any air sampling pipe system constructed with cements other than those recommended.Please note The PIP-021 is equivalent to the REDFLXI25B.

GBP 24.38
1

Vesda-E VEA VSP-991 4mm Microbore Tube 50m

Vesda-E VEA VSP-991 4mm Microbore Tube 50m

Vesda-E VEA VSP-991 4mm Microbore Tube 50mVESDA-E VEA microbore tubes are custom made high quality plenum rated flame retardant polyethylene tubes. They have superior stress crack resistance for reliable long-term performance. They are lightweight and flexible for easy handling and installation and marked with a white ink numbering system over the full length of the tubing.The numbering system includes individual unique identification of each tube and distance marking at regular intervals making them very efficient to install and keep clean installation records. These tubes come in black colour with red stripes for use in smoke detection and meet requirements of global installation codes.These tubes have no active components and they eliminate the need for any electrical wiring for smoke detection resulting in fast and easy installation without the need to follow electrical codes.It is important to use VESDA-E VEA microbore tubes with the VESDA-E VEA detectors to maintain their smoke detection performance.These tubes come in two different diameters 6mm and 4mm. For more information on tube usage refer to VESDA-E VEA Product Guides documents 27034 and 27035 and VEA Microbore Tube Length Calculator document 29262.VEA microbe tube fittings comprise of straight unions and other types of joiners and 6mm to 4mm adaptors for easy installations blanking plugs are used to block the unused ports on VEA.Key FeaturesPlenum ratedFlame retardantHigh quality polyethylene materialStress crack resistantUnique IDDistance marking at regular intervalsMeets requirements of global installation codes

GBP 267.11
1

Vesda VHX-1320 Metal Box HLI Access Protocol

Vesda VHX-1320 Metal Box HLI Access Protocol

Vesda VHX-1320 Metal Box HLI Access ProtocolThe VESDA Access High Level Interface HLI integrates VESDAnet networks with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Access HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information available from VESDA detectors as well as the ability to control and configure these devices.The Access HLI is able to report alarms to the host within a few seconds of a detector reaching an alarm condition. Exact performance is dependent on the polling strategy and size of the monitored network. The Access HLI is able to support up to 100 VESDA detectors on a single VESDAnet network.The wall-mounted version is housed in a metal enclosure allowing for permanent mounting on a flat surface. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module making the wall-mounted HLI a cost-effective solution to your interface requirements.Key FeaturesDirect access and monitoring of your entire VESDAnet networkSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol SupportsVESDA VLP VLS VLC VLF VLI and VFT-15 range of DetectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearnAsynchronous notification of the device state including alarm level detailed faults and current thresholds

GBP 2399.28
1

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 966.89
1

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEXDualPipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 1237.62
1

Vesda Xtralis In-Line Filter Red VSP-850-R

Vesda Xtralis In-Line Filter Red VSP-850-R

Vesda Xtralis In-Line Filter Red VSP-850-RThe Xtralis In-Line Filter provides Xtralis customers the ability to address a wide array of harsh environments with high levels of airborne contaminants in a simple and cost-effective manner.Unlike other in-line filtration solutions available on the market the Xtralis In-Line Filter provides superior performance in terms of improving detector longevity and reducing maintenance frequency. Having tapered inlet and outlet means the Xtralis In-Line Filter is easily fitted in line with the sampling pipe without the need for any additional pipe fittings hence reducing the cost of installation. Filter elements can be easily replaced without having to remove the filter from the pipe network hence simplifying maintenance. Its elegant design blends in seamlessly into the installation where up to four can be installed side-by-side on Xtralis multi-pipe installations.The arrows on the Xtralis In-Line Filter cover indicate the direction of airflow aiding ease of correct mounting. As the airflow enters the filter housing it impinges on the filter elements which are positioned at a certain angle within the filter housing. This arrangement maximizes the filter element surface area subjected to the airflow hence promoting a longer filter life.Key FeaturesSuitable for all Xtralis Aspirating Smoke DetectorsImproved detector longevity in applications with high levels of air-borne contaminationReduces maintenance intervals thus reducing total cost of ownershipRequires no additional pipe fittings thus reducing cost of installationImproved aestheticsVertical or horizontal mountingCompatible with metric 25mm OD and imperial 1 OD pipes eliminating the need for pipe adaptors

GBP 135.30
1

Vesda Xtralis VSP-850-G In-line Filter Grey

Vesda Xtralis VSP-850-G In-line Filter Grey

Vesda Xtralis VSP-850-G In-line Filter GreyThe Xtralis In-Line Filter provides Xtralis customers the ability to address a wide array of harsh environments with high levels of airborne contaminants in a simple and cost-effective manner.Unlike other in-line filtration solutions available on the market the Xtralis In-Line Filter provides superior performance in terms of improving detector longevity and reducing maintenance frequency. Having tapered inlet and outlet means the Xtralis In-Line Filter is easily fitted in line with the sampling pipe without the need for any additional pipe fittings hence reducing the cost of installation. Filter elements can be easily replaced without having to remove the filter from the pipe network hence simplifying maintenance. Its elegant design blends in seamlessly into the installation where up to four can be installed side-by-side on Xtralis multi-pipe installations.The arrows on the Xtralis In-Line Filter cover indicate the direction of airflow aiding ease of correct mounting. As the airflow enters the filter housing it impinges on the filter elements which are positioned at a certain angle within the filter housing. This arrangement maximizes the filter element surface area subjected to the airflow hence promoting a longer filter life.Key FeaturesSuitable for all Xtralis Aspirating Smoke DetectorsImproved detector longevity in applications with high levels of air-borne contaminationReduces maintenance intervals thus reducing total cost of ownershipRequires no additional pipe fittings thus reducing cost of installationImproved aestheticsVertical or horizontal mountingCompatible with metric 25mm OD and imperial 1 OD pipes eliminating the need for pipe adaptors

GBP 135.30
1