Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

29 results (0,14997 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley HLS-RES-V3REP-PL Response Plus Repeater

Vesda VSP-001 VLP amp VLS Programmer Module

Vesda Xtralis LT-ACC-HUB-PWR-HON Hub Direct Power LT Gen 3

Vesda Xtralis VSP-025 Filter Cartridge for VLP VLS VLC amp VLF Pack of 20

Vesda-E VEA VER-A40-40-STX 40-Relay Local StaX Silver

Vesda Xtralis VSW-216 VSM4 Additional PC Licence

Vesda Xtralis VSW-206 VSM4 Primary PC Licence

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount ProgrammerThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review. Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 955.28
1

Vesda VHH-100 Hand Held Programmer Complete with Lead

Vesda VHH-100 Hand Held Programmer Complete with Lead

Vesda VHH-100 Hand Held Programmer Complete with LeadThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack.The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review.Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 919.70
1

Vesda VIC-010 VESDAnet Card for VLF-250 amp VLF-500

Vesda Xtralis OSE-HP-01 OSID Emitter - High Power - Alkaline Battery

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 CoverageThe OSI-10 covers a distance of 30 - 150m with the OSE-SPW. This configuration is for a 1 on 1 system and is not suitable to work with high powered emitters.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.3D Volumetric CoverageA significant benefit of OSID is its ability to provide volumetric coverage. As many as seven emitters can be placed within the field of view of a single imager each placed at different heights. The OSID imagers large viewing angles both horizontal and vertical enable three-dimensional area coverage for design flexibility and additional deployment savings. Unlike other volumetric technologies OSID delivers absolute calibration for consistent detection performance regardless of lighting conditions smoke colour airflows or other environmental conditions.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floorsThe OSI-10 Imager must be paired with either the OSE-SP-01 or OSE-SPW Standard Power Emitter. The OSI-10 can only support one emitter.

GBP 671.33
1

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Grey

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Grey

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - GreyThe Flush Mount Sampling Point patent pending provides a functionally and aesthetically improved alternative to the conical sampling point used in Xtralis Aspirating Smoke Detection ASD pipe networks.Unlike the conical sampling point the Flush Mount Sampling Point provides an easier and faster installation due to its unique design allowing the installation to be completed from one side of a ceiling. It incorporates text XTRALIS FIRE DETECION SYSTEM DO NOT PAINT complying with codes and standards.Designed for secure connection through push fit the sampling point accommodates the various regional capillary tube sizes 6 mm 8 mm 10 mm and commonly used with Xtralis ASD pipe networks making it deployable in all regions. It also accommodates an optional push-in connect adaptor kit VSP-878 for the Americas for increased robustness when used with larger diameter capillary tubing.Its elegant flush design blends in seamlessly into the installation providing considerably improved aesthetics.Key FeaturesSuitable for all Xtralis Aspirating Smoke Detectors providing a standard solutionUnique wing-lock arrangement permits installation from bottom side of ceiling which is ideal for fixed ceilings where access to the other side would be difficult or otherwise impossibleAdjustable wing-lock height to accommodate different ceiling panel thicknessesIncorporates text compliant with codes and standardsDesigned for secure connection through push fitFlush mount design provides less obtrusive installation and improved aestheticsTapered sampling hole helps resist cloggingRoHSREACH compliantPlease note This image is for illustrative purposes only

GBP 25.51
1

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Black

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Black

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - BlackThe Flush Mount Sampling Point patent pending provides a functionally and aesthetically improved alternative to the conical sampling point used in Xtralis Aspirating Smoke Detection ASD pipe networks.Unlike the conical sampling point the Flush Mount Sampling Point provides an easier and faster installation due to its unique design allowing the installation to be completed from one side of a ceiling. It incorporates text XTRALIS FIRE DETECION SYSTEM DO NOT PAINT complying with codes and standards.Designed for secure connection through push fit the sampling point accommodates the various regional capillary tube sizes 6 mm 8 mm 10 mm and commonly used with Xtralis ASD pipe networks making it deployable in all regions. It also accommodates an optional push-in connect adaptor kit VSP-878 for the Americas for increased robustness when used with larger diameter capillary tubing.Its elegant flush design blends in seamlessly into the installation providing considerably improved aesthetics.Key FeaturesSuitable for all Xtralis Aspirating Smoke Detectors providing a standard solutionUnique wing-lock arrangement permits installation from bottom side of ceiling which is ideal for fixed ceilings where access to the other side would be difficult or otherwise impossibleAdjustable wing-lock height to accommodate different ceiling panel thicknessesIncorporates text compliant with codes and standardsDesigned for secure connection through push fitFlush mount design provides less obtrusive installation and improved aestheticsTapered sampling hole helps resist cloggingRoHSREACH compliantPlease note This picture is for illustrative purposes only

GBP 25.06
1

Vesda VSP-005 VLP VLS VLC amp VLF Filter

Vesda VSP-005 VLP VLS VLC amp VLF Filter

Vesda VSP-005 VLP VLS VLC VLF FilterThe VESDA replacement filter cartridge is used to replace filter cartridges in VESDA LaserCOMPACT LaserFOCUS LaserPLUS and LaserSCANNER detectors. One model fits all detectors.Importance of Changing the FilterThe filters used in VESDA detectors are key to the performance of the detector. VESDA filers remove dust contamination from the sampled air providing a clean air bleed to preserve the optics in the detection chamber. Like any other filter filters in VESDA detectors must be replaced regularly to ensure optimum efficiency.It is recommended that the filter is replaced in the VESDA VLC VLS VLP and VLF every two years to maintain the operational integrity of the detector you may want to consider replacing the filter more frequently if the detector is used in dusty or dirty conditions. Instructions on how to do this can be found in the replacement instructions in the download section below.Replacing the FilterBefore replacing the filter in your detector it may be necessary to advise any monitoring authorities that the detector may be offline for a short period.Ensure that the area surrounding the filter is clear of dirt and debris and remove the filter. Do not attempt to clean and reuse the filter VESDA filters are intended for single-use only. Once the new filter has been inserted the detector needs to be informed that a new filter has been installed.Key FeaturesEasy swap replacement filterFits VLC VLF VLP and VLS VESDA detectorsAvailable singly or in packs of 2090 mm x 63 mm x 30 mm 3.5 in. x 2.5 in. x 1.2 in.

GBP 69.64
1

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish Honeywell OnlyThe VESDA ModBus High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs or Fire Alarm Control Panels FACPs otherwise known as host that support the ModBus protocol. There are two models availableModBus HLI Type 1 VHX-0400 which echoes each character received on the RS232 link back to the host together with reply message.ModBus HLI Type 2 VHX-0410 which has the echoing function disabled.Key FeaturesDirect access and monitoring of your VESDAnet system.Seamless data transfer.Easily configured using Xtralis configuring and monitoring software packages.DescriptionOne ModBus HLI is used to interface to a VESDAnet. Modbus HLI supports up to a maximum of 40 VESDA detectors on a VESDAnet.The Modbus HLI supports VESDAnet detector zone numbers between 1 to 200. The Modbus HLI divides up the address range into to 7 logical networks. For example the first 30 addresses are considered in network 1 addresses between 31 to 60 are in network 2 and so on.Smoke and Alarm LevelsThe Smoke Level is reported relative to the Fire Alarm threshold where the full scale is 20. For example if the Fire Alarm threshold is 0.5 obsm a level of 0.1obsm is reported as 4. In other words the Actual Smoke level Reported smoke value Fire1 Threshold 20.FaultsAll VESDAnet faults are mapped on one or more of the Modbus HLI faults which are listed belowHead FaultHead Fault Battery and MainsHead Fault Scanner2 and Flow FaultVESDAnet faults categorised as network faults are mapped onto all zones whereas zone faults are mapped onto that particular zone.

GBP 1328.53
1

Vesda Xtralis Flush Mount Sampling Point VSP-877

Vesda Xtralis Flush Mount Sampling Point VSP-877

Vesda Xtralis Flush Mount Sampling Point VSP-877Unlike the conical sampling point the Flush Mount Sampling Point provides an easier and faster installation due to its unique design allowing the installation to be completed from one side of a ceiling.It incorporates text XTRALIS FIRE DETECION SYSTEM DO NOT PAINT complying with codes and standards. Designed for secure connection through push fit the sampling point accommodates the various regional capillary tube sizes 6 mm 8 mm 10 mm and commonly used with Xtralis ASD pipe networks making it deployable in all regions.It also accommodates an optional push-in connect adaptor kit VSP-878 for the Americas for increased robustness when used with larger diameter capillary tubing.Its elegant flush design blends in seamlessly into the installation providing considerably improved aesthetics.Key FeaturesSuitable for all Xtralis AspiratingSmoke Detectors providing a standard solutionUnique wing-lock arrangement permits installation from bottom side of ceiling which is ideal for fixed ceilings where access to the other side would be difficult or otherwise impossibleAdjustable wing-lock height to accommodate different ceiling panel thicknessesIncorporates text compliant with codes and standardsDesigned for secure connection through push fitAccommodates several capillary tube sizes including 6 mm 8 mm 10 mm and to suit various regional requirementsAccommodates an optional Push-in Connect Adaptor for the Americas capillary tubing for increased robustnessFlush mount design provides less obtrusive installation and improved aestheticsStandard 2 mm 564 pilot sampling hole which can be drilled out up to 5 mm 1364 as per system design calculationsTapered sampling hole helps resist cloggingSnap-fit fascia conceals sampling hole which is easily removable to permit cleaning if requiredRoHSREACH compliant

GBP 22.57
1

Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500

Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500

Vesda Xtralis VIC-020 Multi-Functional Control Card VLF for VLF-250 VLF-500The VESDA VLF MCC Multi-function Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An MCC expands the range of input and output communications a VLF detector can perform.Why use a VLF MCCInstalling a VLF MCC into a VLF detector provides a cost-effective solution for customers who need enhanced connectivity fault detection and monitoring and annunciation of alarms and faults. The principal benefits includeImproved FACP connectivityThe VLF is fitted with two 2 alarm relays in its standard form. With an extra two 2 relays the Multi-function Control Card allows reporting of all four 4 alarm levels on dry relay outputs.Enhanced annunciationAn MPO Monitored 24 V Powered Output is available on the VIC-030 version of the card. The MPO provides power to devices such as sirens or strobes and monitors the line integrity.Enhanced control and fault detectionWith a VLF MCC installed a VLF has two 2 General Purpose Inputs GPIs allowing for example one GPI to report on loss of mains power and the other GPI to be used as a reset input. The VIC-030 version of the card has a self-configuring GPI depending on the jumper selection for MPORelay3.If MPO is selected activation of the GPI will disable the MPO.If Relay3 is selected the GPI will be set to External Fault e.g. for mains power supply monitoring.Key FeaturesProvides two 2 additional relaysProvides an extra General-Purpose Input GPI with line monitoringQuick and simple to installOut-of-the-box operation with minimal configuration required for extra featuresDiagnostic LEDs give visual indication of the cards statusFully compatible with Xtralis VESDA VLF smoke detector

GBP 246.11
1

Vesda Xtralis OSID Emitter Wired 24Vdc OSE-SPW

Vesda Xtralis OSID Emitter Wired 24Vdc OSE-SPW

Xtralis OSID Emitter Wired 24Vdc OSE-SPWThe OSE-SPW is used as a preferred solution when 24 Vdc is close by.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floors

GBP 326.59
1

Vesda Xtralis VIC-030 Multi-Functional Control Card amp Monitored Output for VLF-250 amp VLF-50

Vesda Xtralis VIC-030 Multi-Functional Control Card amp Monitored Output for VLF-250 amp VLF-50

Vesda Xtralis VIC-030 Multi-Functional Control Card Monitored Output for VLF-250 VLF-50The VESDA VLF MCC Multi-function Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An MCC expands the range of input and output communications a VLF detector can perform.Why use a VLF MCCInstalling a VLF MCC into a VLF detector provides a cost-effective solution for customers who need enhanced connectivity fault detection and monitoring and annunciation of alarms and faults. The principal benefits includeImproved FACP connectivity The VLF is fitted with two 2 alarm relays in its standard form. With an extra two 2 relays the Multi-function Control Card allows reporting of all four 4 alarm levels on dry relay outputs.Enhanced annunciation An MPO Monitored 24 V Powered Output is available on the VIC-030 version of the card. The MPO provides power to devices such as sirens or strobes and monitors the line integrity.Enhanced control and fault detection With a VLF MCC installed a VLF has two 2 General Purpose Inputs GPIs allowing for example one GPI to report on loss of mains power and the other GPI to be used as a reset input. The VIC-030 version of the card has a self-configuring GPI depending on the jumper selection for MPORelay3.If MPO is selected activation of the GPI will disable the MPO.If Relay3 is selected the GPI will be set to External Fault e.g. for mains power supply monitoring.Key FeaturesProvides two 2 additional relaysProvides an extra General-Purpose Input GPI with line monitoringQuick and simple to installOut-of-the-box operation with minimal configuration required for extra featuresDiagnostic LEDs give visual indication of the cards statusFully compatible with Xtralis VESDA VLF smoke detector

GBP 397.16
1

Vesda VHX-0420 PC Link HLI Modbus MK3

Vesda VHX-0420 PC Link HLI Modbus MK3

Vesda VHX-0420 PC Link HLI Modbus MK3The VESDA Modbus Type 3 High Level Interface HLI integrates VESDAnet network with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Modbus Type 3 HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information that is available from VESDA detectors as well as the ability to control and configure these devices.Alarms are reported to the host within a few seconds of a detector reaching an alarm condition. Exact performance is dependent on the polling strategy and size of the monitored network. The Modbus Type 3 HLI is able to support up to 100 VESDA detectors on a single VESDAnet network. A standard unit used to provide a flexible solution where permanent mounting is not required. In this case a VESDAnet socket interface is required to connect the HLI onto the VESDAnet network.A VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM4 and2 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol SupportsVESDA VLP VLS VLC VLF VLI and VFT-15 detectorsVESDA-E VEP VEU and VEA detectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearn

GBP 1304.62
1

Vesda Xtralis FTD-8865-S Failsafe Thermography Detector FTD

Vesda Xtralis FTD-8865-S Failsafe Thermography Detector FTD

Vesda Xtralis FTD-8865-S Failsafe Thermography Detector FTDXtralis VIS-IR is a standalone edge device for early fire detection and communicates directly with FACP using on-board Pre-Alarm Alarm and Fault relays avoiding the ever-present failure risk associated with systems that cannot perform detection on the edge.The system is programmable to trigger pre-alarms and alarms based on different fixed temperatures or rate of rise for different regions of interest ROI to suit different environments. This way one device can monitor multiple ROIs simultaneously and only trigger an alarm when a specific area reaches its defined fixed temperature or rate of rise.ViSM VIS-IR Software Management allows for configuration and continuous monitoring of the protected area. Combined with both IR and Video feed ViSM allows the situation to be assessed remotely and safely. This visual verification capability means that situations can be analyzed more accurately so that appropriate action can be taken sooner. So theres less danger disruption and downtime.The earlier a fire is detected the greater the opportunity to take action to reduce the danger to life property and business.Xtralis VIS-IR incorporates a range of advanced features to optimize early detection reduce false alarms enhance reliability and extend the range of operating environments where it can deliver maximum protection.Key FeaturesEarly fire detectionMultiple alarm and pre-alarm settings with fixed temperature and Rate of Rise triggersMultiple Regions of Interest with individually set pre-alarmsalarmsReliable operationSmart camera enabling edge configuration with direct connection to the FACP and no networked PC requiredOnboard failsafe fault relays protecting the system against any fault conditionsReal-time monitoringBuilt-in software for real-time visual verification of alarms enabling human situational assessment and targeted responseRecorded video allowing post-event root cause analysis and corrective actions such as configuration settings adjustmentsFor tough environmentsDetection temperature range of -5C to 450CIP66 certified

GBP 5956.21
1

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master SlaveA VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM4 and2 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host.In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI can report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesInformation AvailableDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2.Configuration of Day Night alarm thresholds2

GBP 1292.38
1