Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

18 results (0,15872 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis VSP-004 VLS Display Module

Vesda Xtralis VLP Display Module VSP-002

Vesda VRT-W00 Remote Mount Display for VLF cw Remote Termination Card amp No Relays

Vesda VRT-V00 Remote Mount Display for VLF cw Remote Termination Card amp 7 Relays

Vesda Xtralis VRT-T00 VLI Remote Mount Display without Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 RelaysDisplay modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2-digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.There are various versions of the display module depending on the type of detector and the relay configuration required.Smoke IndicationSmoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level.To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.Status LightsHigh intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Numeric DisplayA 2 digit numerical readout has a number of modes that are indicated by up to four LEDs The current smoke level in obscurationm obscurationft Fire 1 threshold in obscurationm obscurationft. This is the sensitivity of the detectorKey Features Provides Immediate Status Reporting for a Single VESDA Zone Allows Zone Control of Assigned VESDA Detector High Intensity Alarm LEDs Remote Relay Option 20-Segment Vertical Bar Graph Display Alarm Threshold Indicators Built-In Sounder for Audible Warning Comprehensive Fault Reporting Multi-mode Numeric Display defaults to smoke obscuration Recessed Mounting Option

GBP 1014.77
1

Vesda Xtralis 25mm Air Sampling Test Point - Pack of 10

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 RelaysThe VRT-800 is a Remote Display Module designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1158.24
1

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relaysThe VRT-J00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1167.56
1

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No Relays

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No Relays

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No RelaysThe VRT-K00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 993.19
1

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No Relays

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No Relays

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No RelaysThe VRT-600 is a Remote Mount Display Module designed for use with the LaserPLUS range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 896.96
1

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No RelaysThe VRT-700 is a Remote Display Module with Remote Termination Card which has been designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 899.88
1

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 Relays

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 Relays

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 RelaysThe VRT-200 is a LaserPLUS Display Module with Remote Termination Card 7 Relays.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 984.44
1

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 RelaysThe VRT-400 is a LaserSCANNER Display Module with Remote Termination Card.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1120.91
1

Xtralis OSID Emitter High Power Wired 24 Vdc OSE-HPW

Xtralis OSID Emitter High Power Wired 24 Vdc OSE-HPW

Xtralis OSID Emitter High Power Wired 24 Vdc OSE-HPWOpen-area Smoke Imaging DetectionOSID provides projected beam smoke detectiontechnology. By using advanced dualwavelength projected beams andoptical imaging technology for earlywarning smoke detection OSIDprovides a low-cost reliable andeasy-to-install solution that overcomestypical beam detection issues such asfalse alarm incidents and alignmentdifficulties.Key FeaturesMaximum detection range of 150 m 492 ft for the OSI-10Maximum detection range for CPR approved products is 200 m 656 ftDual wavelength LED-based smoke detectionOptical imaging with CMOS imaging chipOn-board event log for fault and alarm diagnosticsHigh tolerance to false alarm due to building movementHigh tolerance to transient dust steam and intrusion of solid objectsEasy alignment with large adjustment and viewing anglesNo need for precise alignmentTolerant of alignment driftAutomatic commissioning in under ten minutesSimple DIP switch configurationSimple and easy maintenance requirementsThree selectable alarm thresholdsStatus LEDs for Fire Trouble and PowerConventional alarm interface for straightforward fire system integration3-D Volumetric CoverageA significant benefit of OSID is its ability to provide volumetric coverage. As many as seven emitters can be placed within the field of view of a single imager each placed at different heights. The OSID imagers large viewing angles both horizontal and vertical enable three-dimensional area coverage for design flexibility and additional deployment savings. Unlike other volumetric technologies OSID delivers absolute calibration for consistent detection performance regardless of lighting conditions smoke colour airflows or other environmental conditions.ApplicationsLarge open spaces where high-sensitivity detection is not the priority but reliable easy detection is essential includingAirportsTrain stationsShopping centresStadiumsHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floors

GBP 326.59
1

Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD Tube

Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD Tube

Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD TubeDue to the aesthetic design of some buildings such as ornate ceilings or ceiling art-work a discreet unobtrusive smoke detection system is often desirable. Large open atria or voids feature stratified thermal layers that can prevent cooled smoke from reaching ceiling level. As such conventional systems will normally only respond when a fully-fledged fire condition is reached by which time significant damage has already occurred.VESDA provides the discreet detection required in heritage buildings by routing the sampling pipes in areas that are not visible from normal occupancy. Small-bore capillary pipes are used to provide detection at the required location. The room fabric often dictates the location of these capillary tubes. Hiding the capillary tubes behind light fittings blending in with ceiling paintings or forming part of the ceiling sculptures can all be used to provide invisible smoke detection. In high volume atria applications such as cathedrals capillary sample points can be routed into the area at intermediate vertical levels to good effect to overcome stratification. The higher potential sensitivity of the VESDA system means that less smoke is required at the sample points to provide an alarm condition.With over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Key FeaturesFor use with Red or White ABSOperating temperature range -40C to 70CLPCB approvedEN54 testedApplications Used inChurchesHospitalsMuseums GalleriesPrisonsLibrariesArchivesConcert HallsPlease Note The PIP-015 is equivalent to the REDASP025F.

GBP 9.07
1

Vesda OSI-RE-SS OSID R Reflective Beam

Vesda OSI-RE-SS OSID R Reflective Beam

Vesda OSI-RE-SS OSID R Reflective BeamThe Vesda OSI-RE-SS is a 4-wire single-ended reflected type beam smoke detector that includes an 8 reflector and an integral sensitivity test.The Vesda OSI-RE-SS is a reflector-type linear optical beam smoke detector designed to operate as a component of fire alarm systems. The beam operates primarily on the principle of light obscuration utilising an Infra-Red beam. Optical beam smoke detectors are particularly appropriate for protecting buildings with large open spaces such as warehouses atriums etc.The OSI-RE-SS detector is a combined transmitterreceiver unit that can be directly connected to a conventional detector circuit.Key FeaturesCombined transmitter and receiver unit range 5-100 m 16-328 ftConventional modelReceiver consists of a CMOS imaging CCDWide 12 field of viewIntuitive beam alignment indicated by directional arrowsSingle IR wavelengthHighly resistant to building movement tolerates - 1 movementResistant to strong light sources does not alarm when saturated by sunResistant to large solid intruding objectsAutomatic sensitivity threshold level setting50 horizontal and 20 vertical beam alignmentBuilt-in heaterElectronic simulated smoke test from ground levelStandby fault and alarm LED indicators visible from the front and bottomAutomatic drift compensationPaintable coverRemovable plug-in terminal blocksOptional heater kit available for the reflectorThe Infra-Red transmitter and receiver Imager generates a beam of light towards a high efficiency reflector. The reflector returns the beam to the receiver where an analysis of the received signal is made. The change in the strength of the received signal is used to determine the alarm condition.The receiver imager has a wide FOV of 12 and tracks automatically the reflector in case of building movement or movement of its support structure. It is virtually impossible for the receiver to lose the reflector out of its side of view without any structural damage being caused to the building. As a result of this operation the OSI-RE-SS eliminates the number one cause of false alarms andor faults with traditional beam detectors.Optical filtering high-speed image acquisition and intelligent software algorithms provide the OSID-RE system with higher levels of stability and with greater resistance to high level lighting variability. As such the detector has a better resistance to sunlight and intruding objects in its FOV.The detector will not alarm when saturated by sunlight reflected sunlight or any other very bright light sources. In worst case the detector will go in to trouble and hence solving another cause of false alarms with traditional basic photocell receiver beam detectors. Thanks to the smoke imaging techniques the detector will not alarm for partial and sudden blockage.The alignment of the detector is extremely intuitive fast and accurate. Both the IR transmitter and the CMOS imager are contained in the eyeball that can turn freely in all directions. The eyeball moves - 20 in the vertical direction and 50 in the horizontal direction. Four arrows that indicate the direction to move the eyeball will guide the user to find the imagers perfect alignment with the reflector.To get started swiftly at long distances a laser tool can be inserted in the eyeball to allow finding the reflector quickly and then fine-tuning the eyeball to the optimum alignment. Once the optimum alignment is finalised signalled by all green arrows and LED the eyeball is locked by tightening the lever on its side. A paintable cover is then placed over the front to hide the alignment arrows locking mechanism and secures the locking lever in locked position. Unique in the market the sensitivity of the detector is selected and set automatically at the optimum sensitivity based on the size of the reflector measured in the FOV. The detector incorporates automatic drift compensation whereby the detector will adjust its detection thresholds in line with any long term signal reduction of the beam caused by contamination of the optical surfaces. An internal heating option is also provided on the Imager to prevent condensation on the optical surface.

GBP 870.91
1

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 CoverageThe OSI-10 covers a distance of 30 - 150m with the OSE-SPW. This configuration is for a 1 on 1 system and is not suitable to work with high powered emitters.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.3D Volumetric CoverageA significant benefit of OSID is its ability to provide volumetric coverage. As many as seven emitters can be placed within the field of view of a single imager each placed at different heights. The OSID imagers large viewing angles both horizontal and vertical enable three-dimensional area coverage for design flexibility and additional deployment savings. Unlike other volumetric technologies OSID delivers absolute calibration for consistent detection performance regardless of lighting conditions smoke colour airflows or other environmental conditions.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floorsThe OSI-10 Imager must be paired with either the OSE-SP-01 or OSE-SPW Standard Power Emitter. The OSI-10 can only support one emitter.

GBP 671.33
1