Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

17 results (0,14430 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vimpex IS-L101L-RA IS Intrinsically Safe Beacon - Amber

Vimpex IS-L101L-RR IS Intrinsically Safe Beacon - Red

Vimpex IS-L101L-RB IS Intrinsically Safe Beacon - Blue

Vimpex IS-L101L-RY IS Intrinsically Safe Beacon - Yellow

Vimpex IS-L101L-RC IS Intrinsically Safe Beacon - Clear

Vimpex IS-L101L-RG IS Intrinsically Safe Beacon - Green

Vimpex SL-HDP-JB Signaline HD JB Programmable Linear Heat Cable Junction Box

Vimpex SL-HDP-LHC Signaline HD Programmable Linear Heat Cable - 50m

Vimpex SL-HDP-LHC-N Signaline HD -R Programmable Linear Heat Cable Nylon Coated - 50m

Vimpex SL-HDP-LHC-S Signaline HD -S Programmable Linear Heat Cable Stainless Steel Braid - 50m

Vimpex ID-WLARI Hydrosense Addressable Remote Indicator

Vimpex SL-HDP-CTL Signaline HD Controller - Programmable Linear Heat Cable Controller

Vimpex Loop Sounder with Short Circuit Isolator ELS2A6AO

Vimpex Loop Sounder with Short Circuit Isolator ELS2A6AO

Vimpex Loop Sounder with Short Circuit Isolator ELS2A6A0Installing a Vimpex Loop Sounder System with short-circuit isolation provides complete sounder circuit integrity. By wiring the sounder circuit in a loop instead of a traditional radial all sounders will remain operational in the event of a short-circuit or open circuit fault.Component parts are approved by LPCB to relevant parts of EN 54 and the system is fully compliant with BS 5839-1 using a single sounder loop. Use of the Vimpex Loop Sounder System will greatly increase the reliability of the sounder circuits and in many cases result in a saving in the amount of cable used.Each loop can accommodate up to 45 sounders. Suitable for use on both conventional and addressable fire alarm systems the system provides much greater protection against faults than the dual radial circuit arrangements commonly used.The Vimpex Loop Sounder System significantly enhances the reliability of any sounder system. With conventional radial circuits a single open or short circuit fault on a sounder circuit could result in the loss of at least half of the sounders in an area of a building.Each sounder is supplied with a bi-directional short-circuit isolator fitted within its base. In the event of a short circuit the isolators will activate and disconnect the faulty section of cable while reporting in monitoring mode the fault to the control panel. When the sounders are activated the loop is driven from both ends ensuring that all sounders will remain operational even in the event of a single short-circuit or open-circuit fault. Sounders and their isolator bases are installed just like any other conventional sounders on the twin core circuit.Key FeaturesApproved to EN 54

GBP 44.11
1

Vimpex ELS2A4AO Loop Sounder with Shallow Base in White

Vimpex ELS2A4AO Loop Sounder with Shallow Base in White

Vimpex ELS2A4AO Loop Sounder with Shallow Base in WhiteInstalling a Vimpex Loop Sounder System with short-circuit isolation provides complete sounder circuit integrity. By wiring the sounder circuit in a loop instead of a traditional radial all sounders will remain operational in the event of a short-circuit or open circuit fault.Component parts are approved by LPCB to relevant parts of EN 54 and the system is fully compliant with BS 5839-1 using a single sounder loop. Use of the Vimpex Loop Sounder System will greatly increase the reliability of the sounder circuits and in many cases result in a saving in the amount of cable used.Each loop can accommodate up to 45 sounders. Suitable for use on both conventional and addressable fire alarm systems the system provides much greater protection against faults than the dual radial circuit arrangements commonly used.The Vimpex Loop Sounder System significantly enhances the reliability of any sounder system. With conventional radial circuits a single open or short circuit fault on a sounder circuit could result in the loss of at least half of the sounders in an area of a building.The Vimpex Loop Sounder System has been fully tested and approved by LPCB to relevant EN 54 standards - certificates are available on request. This system is detailed in BS 5839-12002A22008 clause 12.2.2 j and Fig 1b as an alternative to the use of dual radial circuits. A detailed application guide is available from Vimpex as is a system loop calculator.Each sounder is supplied with a bi-directional short-circuit isolator fitted within its base. In the event of a short circuit the isolators will activate and disconnect the faulty section of cable while reporting in monitoring mode the fault to the control panel. When the sounders are activated the loop is driven from both ends ensuring that all sounders will remain operational even in the event of a single short-circuit or open-circuit fault. Sounders and their isolator bases are installed just like any other conventional sounders on the twin core circuit.

GBP 44.11
1

Vimpex ELS3A6AO Loop Sounder with Deep Base IP66 in Red

Vimpex ELS3A6AO Loop Sounder with Deep Base IP66 in Red

Vimpex ELS3A6AO Loop Sounder with Deep Base IP66 in RedInstalling a Vimpex Loop Sounder System with short-circuit isolation provides complete sounder circuit integrity. By wiring the sounder circuit in a loop instead of a traditional radial all sounders will remain operational in the event of a short-circuit or open circuit fault.Component parts are approved by LPCB to relevant parts of EN 54 and the system is fully compliant with BS 5839-1 using a single sounder loop. Use of the Vimpex Loop Sounder System will greatly increase the reliability of the sounder circuits and in many cases result in a saving in the amount of cable used.Each loop can accommodate up to 45 sounders. Suitable for use on both conventional and addressable fire alarm systems the system provides much greater protection against faults than the dual radial circuit arrangements commonly used.The Vimpex Loop Sounder System significantly enhances the reliability of any sounder system. With conventional radial circuits a single open or short circuit fault on a sounder circuit could result in the loss of at least half of the sounders in an area of a building.The Vimpex Loop Sounder System has been fully tested and approved by LPCB to relevant EN 54 standards - certificates are available on request. This system is detailed in BS 5839-12002A22008 clause 12.2.2 j and Fig 1b as an alternative to the use of dual radial circuits. A detailed application guide is available from Vimpex as is a system loop calculator.Each sounder is supplied with a bi-directional short-circuit isolator fitted within its base. In the event of a short circuit the isolators will activate and disconnect the faulty section of cable while reporting in monitoring mode the fault to the control panel. When the sounders are activated the loop is driven from both ends ensuring that all sounders will remain operational even in the event of a single short-circuit or open-circuit fault. Sounders and their isolator bases are installed just like any other conventional sounders on the twin core circuit.

GBP 45.36
1

Vimpex SY-GD03 Sav Wire Conventional Sycall Reset Glow Dual Mounting - Green

Vimpex SY-GD03 Sav Wire Conventional Sycall Reset Glow Dual Mounting - Green

Vimpex SY-GD03 Sav Wire Conventional Sycall Reset Glow Dual Mounting - GreenThe Sycall Reset-Glow series of resettable manual call points mimics the feel of breaking glass whilst offering the user benefits and environmental advantages of a resettable operating element. Internal and weatherproof units are available and all variants can be easily identified by an alarm flag which rises into view upon activation. Location assistance is further enhanced by an in-built LED ring which illuminates the central operating window of the Series 01 and 03 units.A special photo-luminescent pigment is also incorporated within the white plastic operating window. In the event of a power failure or reduced light conditions Reset-Glow will remain visible for approximately 5 minutes to assist location for building occupants. The Sycall Reset-Glow provides an ideal solution for most conventional fire alarm systems. It is ideal for industries that are sensitive to broken glass as well as areas that suffer from a high number of false activations such as schools shopping centres and other public places.Key Features Third party tested to EN54-11 Red Series 01 onlyHighly visible during alarm conditionVisible in the dark via the unique luminescent resettable element featureEasy and economical installationHigh impact resistant ABS plastic material - available in Red Blue Green Yellow and WhiteSurface mount and flush mount options availableExtremely easy to reset via the robust twist and set key system

GBP 19.64
1

Signaline SLP-001 FT Dual Zone Distance Locator and Monitor

Signaline SLP-001 FT Dual Zone Distance Locator and Monitor

Signaline SLP-001 FT Dual Zone Distance Locator and MonitorThe Signaline SLP-001 LocatorPlus is a combined distance locator and monitor module compatible with all Signaline FT and FT-R linear heatdetection cables.UL approvedthe LocatorPlus gives users instance alarm point location along the Signaline FT linear heat detection cable. However unlike previous locator devices the LocatorPlus can then remotely report this location via the MODBUS output.Furthermore the LocatorPlus can offer location along 2 different zones of Signaline FT cable each upto 3000m long.The LocatorPlus also acts as a monitor module for the linear heat detection. It will report both fire and fault on either zone. These alarms are also indicated via an internal buzzer and LEDs on the LocatorPlus. The LocatorPlus is compatible with any conventional fire detection panel or can operate on an addressable interface. The LocatorPlus can also be used as the activation device on gas releasing panels.The LocatorPlus has two operating modes. Independent mode will report an alarm on either zone of cable independently. However if set to interlocking the alarm relays are not triggered until both zones are in alarm. Thereby removing any risk of false alarms.Key FeaturesModel Signaline LocatorPlus SLP-001Dimensions 180 x 120 x 60.5mm HxWxDIP Rating IP65Finish Light Grey with clear lidDisplay 2 line 16 character backlit display showing zone statusApprovals UL 864 10th ed.Operating voltage 12-36VdcOperating current 12mA 4mAAlarm current 40mA 15mAOperating temp. range -20C 50C -4F 122FTerminal blocks Spacing 5mm Rising ClampRating 16AWire size 0.08mm2 28AWG to 4mm2 11AWGSupervised circuits Power Input Zone 1 Input Zone 2Inputs Up to two zones of Signaline FT or FT-R Linear Heat DetectionZone length 1-3000m 10000ftEnd of Line resistor 1kohm includedShort circuit current 0.5mAMax voltage 5VGround fault impedance 0ohmsCommunications Two wire RS-485 Modbus RTU field wiring limited to same room to comply with UL listingSounder 2.4kHz 92dBa 10cm BuzzerAlarm 2x Form C volt-free relay contacts resistive com-monMax V 30Vac or 42.4VdcMax Current 2A Max Switching Power 60W 62.5VAFault 2x Optoisolated phototransistor output resistive commonMax V 35VdcMax Current 80mA Max Power Dissipation 150mW

GBP 946.61
1