Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

19 results (0,17797 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vimpex FC3ZEP Zone Extension PCB

Signaline SLP-001 FT Dual Zone Distance Locator and Monitor

Signaline SLP-001 FT Dual Zone Distance Locator and Monitor

Signaline SLP-001 FT Dual Zone Distance Locator and MonitorThe Signaline SLP-001 LocatorPlus is a combined distance locator and monitor module compatible with all Signaline FT and FT-R linear heatdetection cables.UL approvedthe LocatorPlus gives users instance alarm point location along the Signaline FT linear heat detection cable. However unlike previous locator devices the LocatorPlus can then remotely report this location via the MODBUS output.Furthermore the LocatorPlus can offer location along 2 different zones of Signaline FT cable each upto 3000m long.The LocatorPlus also acts as a monitor module for the linear heat detection. It will report both fire and fault on either zone. These alarms are also indicated via an internal buzzer and LEDs on the LocatorPlus. The LocatorPlus is compatible with any conventional fire detection panel or can operate on an addressable interface. The LocatorPlus can also be used as the activation device on gas releasing panels.The LocatorPlus has two operating modes. Independent mode will report an alarm on either zone of cable independently. However if set to interlocking the alarm relays are not triggered until both zones are in alarm. Thereby removing any risk of false alarms.Key FeaturesModel Signaline LocatorPlus SLP-001Dimensions 180 x 120 x 60.5mm HxWxDIP Rating IP65Finish Light Grey with clear lidDisplay 2 line 16 character backlit display showing zone statusApprovals UL 864 10th ed.Operating voltage 12-36VdcOperating current 12mA 4mAAlarm current 40mA 15mAOperating temp. range -20C 50C -4F 122FTerminal blocks Spacing 5mm Rising ClampRating 16AWire size 0.08mm2 28AWG to 4mm2 11AWGSupervised circuits Power Input Zone 1 Input Zone 2Inputs Up to two zones of Signaline FT or FT-R Linear Heat DetectionZone length 1-3000m 10000ftEnd of Line resistor 1kohm includedShort circuit current 0.5mAMax voltage 5VGround fault impedance 0ohmsCommunications Two wire RS-485 Modbus RTU field wiring limited to same room to comply with UL listingSounder 2.4kHz 92dBa 10cm BuzzerAlarm 2x Form C volt-free relay contacts resistive com-monMax V 30Vac or 42.4VdcMax Current 2A Max Switching Power 60W 62.5VAFault 2x Optoisolated phototransistor output resistive commonMax V 35VdcMax Current 80mA Max Power Dissipation 150mW

GBP 868.45
1

Vimpex Hydrosense HS Conventional 2 Zone Leak Detection Panel

Vimpex Hydrosense HS Conventional 8 Zone Leak Detection Panel

Vimpex Hydrosense HS Conventional 4 Zone Leak Detection Panel 230VAC

Vimpex SL-FT-EOL-EN Signaline EN 2 Zone EOL Enclosure

Vimpex HSRP-S-2-230 Hydrosense HS Conventional Repeater Panel 2 Zone 230 VAC

Vimpex Hydrosense HS Conventional 8 Zone Leak Detection Panel with Ancillary PCB

Vimpex Hydrosense HS Conventional 8 Zone Leak Detection Panel with Ancillary PCB

Vimpex Hydrosense HS Conventional 8 Zone Leak Detection Panel with Ancillary PCB 230v ACThe new Hydrosense systems provide both linear detection using Hydrowire and point detection using probes. Linear detection Hydrowire is a flexible cable which will continuously monitor large areas. When even a small amount of water or moisture comes into contact with Hydrowire it will trigger an alarm. Point detection is provided by Hydrosense floor or drip tray probes these are fixed to the floor or drip tray and adjusted to give the required detection level and connected to the control panel via a Hydrosense water leak detection module.Utilising life safety technology in the design of Hydrosense provides the reliability and integrity of BSi approved fire detection systems meaning there is virtually no risk of failure downtime and significantly fewer false alarms.The ancillary PCB provides common fire common fault coincidence and zonal fire volt free contacts allowing control of sub-systems graphical mimics and plant remotely from the main panel over a two-wire data bus.Key FeaturesIdeal for small and medium sized installations2 4 and 8 Zone Control Panels available with all variants featuring battery standby as well as common fault and alarm relay contactsSimple to install and maintainDetection and Sounder circuits constantly monitored for faultsRS485 data bus allows both zonal contacts and repeater panels to be incorporatedBattery Backup

GBP 962.56
1

Vimpex Hydrosense HS Conventional 2 Zone Leak Detection Panel with Ancillary PCB

Vimpex Hydrosense HS Conventional 2 Zone Leak Detection Panel with Ancillary PCB

Vimpex Hydrosense HS Conventional 2 Zone Leak Detection Panel with Ancillary PCB 230v AC - HSCP-S-2-AP-230The new Hydrosense systems provide both linear detection using Hydrowire and point detection using probes. Linear detection Hydrowire is a flexible cable which will continuously monitor large areas. When even a small amount of water or moisture comes into contact with Hydrowire it will trigger an alarm. Point detection is provided by Hydrosense floor or drip tray probes these are fixed to the floor or drip tray and adjusted to give the required detection level and connected to the control panel via a Hydrosense water leak detection module.Utilising life safety technology in the design of Hydrosense provides the reliability and integrity of BSi approved fire detection systems meaning there is virtually no risk of failure downtime and significantly fewer false alarms.The ancillary PCB provides common fire common fault coincidence and zonal fire volt free contacts allowing control of sub-systems graphical mimics and plant remotely from the main panel over a two-wire data bus.Key FeaturesIdeal for small and medium sized installations2 4 and 8 Zone Control Panels available with all variants featuring battery standby as well as common fault and alarm relay contactsSimple to install and maintainDetection and Sounder circuits constantly monitored for faultsRS485 data bus allows both zonal contacts and repeater panels to be incorporatedBattery Backup

GBP 777.22
1

Vimpex Hydrosense HS Conventional 4 Zone Leak Detection Panel with Ancillary PCB

Vimpex Hydrosense HS Conventional 4 Zone Leak Detection Panel with Ancillary PCB

Vimpex Hydrosense HS Conventional 4 Zone Leak Detection Panel with Ancillary PCB 230v ACThe new Hydrosense systems provide both linear detection using Hydrowire and point detection using probes. Linear detection Hydrowire is a flexible cable which will continuously monitor large areas. When even a small amount of water or moisture comes into contact with Hydrowire it will trigger an alarm. Point detection is provided by Hydrosense floor or drip tray probes these are fixed to the floor or drip tray and adjusted to give the required detection level and connected to the control panel via a Hydrosense water leak detection module.Utilising life safety technology in the design of Hydrosense provides the reliability and integrity of BSi approved fire detection systems meaning there is virtually no risk of failure downtime and significantly fewer false alarms.The ancillary PCB provides common fire common fault coincidence and zonal fire volt free contacts allowing control of sub-systems graphical mimics and plant remotely from the main panel over a two-wire data bus.Key FeaturesIdeal for small and medium sized installations2 4 and 8 Zone Control Panels available with all variants featuring battery standby as well as common fault and alarm relay contactsSimple to install and maintainDetection and Sounder circuits constantly monitored for faultsRS485 data bus allows both zonal contacts and repeater panels to be incorporatedBattery Backup

GBP 854.94
1

Vimpex HSRP-S-4-230 Hydrosense HS Conventional Repeater panel 4 zone 230 VAC

Vimpex Intrinsically Safe Sounder Minialarm in Red IS-MA1M-R

Vimpex Intrinsically Safe Sounder Red IS-A105N-R

Vimpex HSCP-AP Ancillary PCB for Hydrosense HS Control Panels

Vimpex Signaline SL-UCB Universal Connection Box