Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

248 results (0,14223 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta SCM-LAN TCPIP Module Connection To Zeta Remote

Zeta BG-EM-K-0-2-0 Button Guard Emergency Push Button Key to Reset with N.O. amp N.C.

Zeta BG-EM-T-0-2-0 Button Guard Emergency Push Button Twist to Reset with N.O. amp N.C.

Zeta PP-212 Premier Power Pack EN54-4 Power Supply 2.0 Amp With Space For Up To 2 X 12Ah 12Vdc SLA Batteries

Zeta PP-517 Premier Power Pack EN54-4 Power Supply 5.0 Amp With Space For Up To 2 X 17Ah 12Vdc SLA Batteries

Zeta SP-126M Simplicity Plus 126 Addressable Fire Alarm Panel - 1 Loop 126 Devices

Zeta SP-126M Simplicity Plus 126 Addressable Fire Alarm Panel - 1 Loop 126 Devices

Zeta SP-126M Simplicity Plus 126 Analogue Addressable Fire Alarm Panel - 1 Loop 126 DevicesMetal EnclosureThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key Features1 Loop 126 DevicesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalOperating Temperature -0C to 50CEnclosure Size 375mm x 335mm x 125mm

GBP 725.08
1

Zeta SP-64M Simplicity Plus 1 Loop 64 Devices Addressable Fire Panel

Zeta SP-64M Simplicity Plus 1 Loop 64 Devices Addressable Fire Panel

Zeta SP-64M Simplicity Plus 1 Loop 64 Devices Addressable Fire PanelThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels. As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages. It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key FeaturesOne or Two loop addressable fire alarm panel 64 126 or 252 device capacityCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalEnclosure Size 375W x 335H x 128D

GBP 661.50
1

Zeta SP-252M Simplicity Plus 252 Addressable Fire Alarm Panel - 2 Loop 252 Devices

Zeta SP-252M Simplicity Plus 252 Addressable Fire Alarm Panel - 2 Loop 252 Devices

Zeta SP-252M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop 252 DevicesMetal EnclosureThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key Features2 Loop 252 DevicesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalEnclosure Size 375mm x 335mm x 125mm

GBP 790.37
1

Zeta SCM-PM Printer Module

Zeta FS-TL-50EX Long Flame Simulator

Zeta MKII-AOPB Fyreye MKII Addressable Optical Smoke Detector - Black

Zeta MKII-AOP Fyreye MKII Addressable Optical Smoke Detector

Zeta FEUV2000 Fyreye Ultra-Violet Flame Detector With Base

Zeta MKII-OH MKII Fyreye MKII Conventional Fyreye Optical-Heat Detector

Zeta ZT-BEAMKIT140 Range Extension Kit 70-140 Metres

Zeta SCM-NM Network Module

Zeta MKII-HR MKII Rate of Rise Heat Detector

Zeta MKII-OPB MKII Optical Smoke Detector - Black

Zeta MKII-OP MKII Optical Smoke Detector

Zeta ZT-BEAMKIT160 Range Extension Kit 140-160 Metres

Zeta 10-060 Wi-Fyre Wireless InputOutput Unit With Batteries Red

Zeta 10-061 Wi-Fyre Wireless InputOutput Unit With Batteries White