Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

4 results (0,12689 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton FDR100-EZ Addressable Loop Powered Reflective Beam Detector 100m

Ziton FDR100-EZ Addressable Loop Powered Reflective Beam Detector 100m

Ziton FDR100-EZ Addressable Loop Powered Reflective Beam Detector 100mThe FDR100-EZ linear beam smoke detector is developed for use in areas where point type detectors would be difficult to install and maintain. The FDR100-EZ has a detection ranges of up to 100 metres. A transmitter and receiver are contained in one enclosure. The transmitter emits an invisible infrared beam which is reflected back to the receiver by a prism mounted directly opposite and in clear line of sight. The presence of smoke obscures the beam and reduces the signal strength detected at the receiver.The FDR100-EZ incorporates continuous monitoring of both electrical and optical faults. If the infrared beam is obscured rapidly to a level above 90 for approximately 10 seconds the condition is seen as a fault. Long-term degradation of signal strength is monitored and adjusted automatically. Installed under flat horizontal ceilings a single unit provides satisfactory smoke detection up to 7.5 metres on either side of the beam axis. For larger areas multi detector systems can be installed. The FDR100-EZ addressable detector is connected directly to the ZP3 loop wiring and is configured with its own address which the control panel poles every two seconds.Alarm thresholds of 25 35 and 50 obscuration are selectable making the detector suitable for a wide range of building environments. The fire output can be set to latch only cancelled by resetting the device or auto reset where the detector is reset automatically 5 seconds after the received infrared signal has recovered to a level above the alarm threshold. The detector and the reflecting prism are installed on opposite walls of the protected area usually between 0.3 and 0.6 metres below ceiling height. With unique alignment features the equipment is easy to install provides high stability and freedom from false alarms.Key FeaturesSingle installation and maintenance pointFully addressable100 metre detection rangeUnique simple alignmentSelectable alarm thresholdsLatching or auto reset fire outputAutomatic contamination compensation

GBP 762.84
1

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery PackThe ZR451-3 is a wireless 868 MHz single channel inputoutput unit. It provides a method of interfacing a supervised input or potential free output signal into and out of the fire detection and alarm system in areas where the installation of system wiring is not an option.The systemThe ZR451-3 communicates with the main control panel via a hardwired radio loop module that can be installed anywhere on the ZP loop. When the input gets an alarm signal it passes it via the radio loop module to the main fire control panel where it is processed. The output of the interface provides volt free change over contacts for connecting ancillary equipment and is programmed separately activated individually on in a group.High intensity LED indicators positioned on the ZR451-3 may be illuminated by a manually activated push button to identify when the interface has operated providing clear identification of the signal source.Installed as part of a ZP addressable system up to 127 line devices sensors call points or interface units may be connected to each of the control panel loops. Each wireless device is assigned its own IDENT address with which the main control panel communicates with it providing the same system facilities as directly wired devices.UsageAs an input the ZR451-3 may receive signals from other alarm equipment e.g. beam detectors aspiration detectors etc. Used as an output the unit switches equipment controlled by the fire detection system e.g. air conditioning systems magnetic door release units etc. Both input and output facilities are available from the same unit and may be operated simultaneously or individually as programmed at the fire control panel.Power supplyThe ZR451-3 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. The ZR451-3 features battery condition monitoring and reporting.Key FeaturesAddressable inputoutput interface unitWire free activationVolt free relay outputMonitored input for fire and faultTwo way radio communication

GBP 234.91
1

Ziton FDR50-EZ Addressable Loop Powered Reflective Beam Detector 50m

Ziton FDR50-EZ Addressable Loop Powered Reflective Beam Detector 50m

Ziton FDR50-EZ Addressable Loop Powered Reflective Beam Detector 50mThe FDR50-EZ linear beam smoke detector is developed for use in areas where point type detectors would be difficult to install and maintain. The FDR50-EZ has a detection ranges of up to 50 metres.A transmitter and receiver are contained in one enclosure. The transmitter emits an invisible infrared beam which is reflected back to the receiver by a prism mounted directly opposite and in clear line of sight. The presence of smoke obscures the beam and reduces the signal strength detected at the receiver.Unique alignment featureAlarm thresholds of 25 35 and 50 obscuration are selectable making the detector suitable for a wide range of building environments. The fire output can be set to latch only cancelled by resetting the device or auto reset where the detector is reset automatically 5 seconds after the received infrared signal has recovered to a level above the alarm threshold.The detector and the reflecting prism are installed on opposite walls of the protected area usually between 0.3 and 0.6 metres below ceiling height. With unique alignment features the equipment is easy to install provides high stability and freedom from false alarms.Continuously monitoredThe FDR50-EZ incorporates continuous monitoring of both electrical and optical faults. If the infrared beam is obscured rapidly to a level above 90 for approximately 10 seconds the condition is seen as a fault. Long-term degradation of signal strength is monitored and adjusted automatically.Installed under flat horizontal ceilings a single unit provides satisfactory smoke detection up to 7.5 metres on either side of the beam axis. For larger areas multi detector systems can be installed.The FDR50-EZ addressable detector is connected directly to the ZP3 loop wiring and is configured with its own address which the control panel poles every two seconds.Key FeaturesSingle installation and maintenance pointFully addressable50 metre detection rangeUnique simple alignmentSelectable alarm thresholdsLatching or auto reset fire outputAutomatic contamination compensation

GBP 627.80
1

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit with Battery PackThe ZCR452 is an interface between a conventional fire detection zone and a range of wireless 868 MHz field devices. It provides a method of interfacing a conventional system with a zone of wireless field devices in areas where the installation of system wiring is not an option.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 allows for any compatible conventional fire detection zone to be connected directly to the unit. The ZCR452 in turn provides fire and fault notifications from the wireless field devices to these conventional circuits. In addition any conventional notification circuit may also be wired to the ZCR452 allowing wireless notification devices to be controlled from the conventional notification controller in a similar way to any hardwired conventional notification device.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. Any abnormal battery condition is reported to the fire system.Key FeaturesProvides conventional systems with wireless capabilitiesNo special conventional interfaces requiredFlexible impedance matching for conventional circuitsMonitors all wireless alarm and fault messagesConventional control interface for wireless notification devices and IOTwo way radio communicationFully EN54 compliant and CPR certified

GBP 194.32
1