Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

8 results (0,12581 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZP886R-RMKIT ZP7 Series Intelligent Addressable Manual Call Point - Recess Mount

Ziton RB108A Relay Board Compatible with GST108A for Zonal Fault amp Fire Alarm Signal Output

Ziton RB102A Relay Board Compatible With GST102A for Zonal Fault amp Fire Alarm Signal Output

Ziton RB116A Relay Board Compatible with GST116A for Zonal Fault amp Fire Alarm Signal Output

Ziton ZP886R-TSKIT ZP7 Series Intelligent Addressable Manual Call Point cw Skirt

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 Loop

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 Loop

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 LoopThe ZPR868-H is a Ziton protocol radio hub for interfacing up to 4 loops of wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP panel and provides a seamless interface between the panel and the wireless devices.Performance and RangeWith support for smart cluster technology the ZPR868-H provides extended wireless coverage over zone type wireless systems. Diversity antennae allows for extended communication range in all directions whilst multipath communication techniques minimises the risk of interference from external sources.System DesignWith up to 4 hardware loops connected directly from the Ziton fire alarm CIE to the ZPR868-H hub every devices on each of the CIE loops may be connected wirelessly. Cluster communicators ZPR868-C or ZPR868-CM communicate on one side wirelessly to the hub and on the other side to up to 31 wireless devices either detectors notification andor IO units and even other clusters. When redundancy is required multipath communication enables clusters to talk to other clusters to find a reliable communication path back to the hub should its own dual communication frequencies be blocked. Clusters can also communicate with other clusters to extend the wireless communication distance for large installations.Full flexibilityWireless devices are featured in many fire detection and alarm systems and are specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal.Key FeaturesFully loop powered4-Loop connectivity to up to 504 wireless devices2-Way communication with up to 31 wireless clustersDiversity transceivers allow maximum operational rangeVariable power outputUnique multi-path smart cluster technology supportAutomatic selection from 32 radio channels for reliable communication868MHz harmonised frequency supportETSI 300-220 approvedEN54-18 25 complaint and CPR certified

GBP 467.40
1

Ziton 2010-2-PAK-RMSDK SDK Services PAK

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop ModuleThe ZP3AB-NLM network loop module enables individual ZP3 control panels to be connected in a peer to peer secure loop network. If there is an open or short circuit present on the network wiring the NLMs determine where the fault lies isolate the faulty section of wiring and maintain full loop integrity.Total cable length throughout the network can be up to a maximum of two kilometres and may be extended by setting designated NLM modules as booster units contact Ziton technical support department for full details. Communication between loop modules operates by RS485 protocol over screened twisted pair wiring.Unique address on the network loopZP3AB-NLM3 modules connect to ZP3 control panels via a ZP3AB-NET1 card and are designed to fit onto an auxiliary chassis inside each control panel or auxiliary equipment cabinet. Each ZP3 control panel is connected to the loop network through an ZP3AB-NLM3 module. All modules incorporate switch settings enabling them to be assigned a unique loop address. An output fault signal is provided by a volt free changeover relay with contacts rated at 1A at 230VDC30VAC.Diagnostic and system indicationIn each network loop one module must be set to address 1 and designated as the master. This device manages the healing sequence and monitors loop integrity. All other modules are connected to the network loop in slave mode.In slave mode modules can operate in multiple modesBoost - serving as an interconnection between panels at distances over 1000 metresHealing establishing the condition of the loop and isolating sections if necessaryRecovered normal condition after a section isolationDiagnostic system interrogation to establish the location of a break in the loop wiringIn addition to indications of data being transmitted and received from each port LED indicators are also provided for System OK Loop Fault Loop Open and Data Error.Key FeaturesProvides a secure loop networkEnhanced LED diagnosticsBoost mode for long cable runsPropagation time periods for third party equipment operationCommunications screen isolation between input and output channels

GBP 277.06
1