Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

11 results (0,14460 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZP755-COV-P Cover For All ZP755B Base Sounders With No Detector - Polar White

Ziton ZP755-COV-R Cover for Base Sounder

Ziton Anti-Condensation Heater FD310 Series FD-CH3

Ziton Anti-Condensation Heater FD800 Series FD-CH2

Ziton DI-9102E Digital Intelligent Optical Smoke Detector with Remote Indicator Output

Ziton ZX432-2P Multi-Sensor Optical Heat Detector for Wireless Use

Ziton ZX432-2P Multi-Sensor Optical Heat Detector for Wireless Use

Ziton ZX432-2P Multi-Sensor Optical Heat Detector for Wireless UseThe ZR432-2P is a wireless POLAR WHITE addressable multisensor capable of operating in optical temperature or multisensor opticalheat modes.Detector controlThe ZR432-2 detector is controlled from the main control panel via a loop wired radio interface module allowing both wireless and hardwired devices to be seamlessly located and controlled from the same wiring loop. Every wireless device controlled through the radio loop module is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.Fast response to a wide range of firesDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432-2 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied.System operationTemperature and smoke sensitivity may be set by a selection of switches located in the base of the ZR432-2. Calibration and self-testing are carried out automatically.Removal or replacement of an incorrect sensing devices are identified by the system and details displayed at the main control panel. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432-2 detectors plug into the radio base by a simple twist and lock action.

GBP 54.52
1

Ziton ZPW766R Wall Mount Sounder VAD Red Body Red Flash

Ziton ZPW766R Wall Mount Sounder VAD Red Body Red Flash

Ziton ZPW766R Wall Mount Sounder VAD Red Body Red FlashThe ZPW766R is a ZP7 series Ziton protocol addressable RED sounder with a built in visual alarm device VAD the latter approved for wall mount applications. The VAD features a clear lens with red LED element. The ZPW766 incorporates a switch setting allowing it to be assigned a unique address on a Ziton fire panel loop.With its durable design high sound output and VAD designed for installation up to a height of 2.4m the ZPW766 ensures reliability and is suitable for a variety of indoor open areas where there is higher than normal background noise whilst the unique lens design of the VAD distributes light evenly over the selected surface area.Sounder VAD CombinationsDisability legislation increasingly requires visual alarm signals to be used to ensure equal response from people with hearing impairment. The ZPW766 is perfectly suited for this application providing synchronised audible and visual warnings from a single loop wired unit. It minimises the number of installation points required in a building significantly lowering the investment value of equipment and loop wiring costs. Installation time costs are further reduced as the device connects directly into a first fix base.Current Consumption System LoadsHigh efficiency acoustic design and a low current VAD enables multiple ZPW766 devices to be connected to a fire panel loop. Depending on system requirements the ZPW766 may be set to use less power both in sound as well as VAD output. When coverage areas are small less than 7.5 m radius reducing the required range minimises the system current load. The flash frequency may also be set to 0.5 Hz 1 flash every 2 seconds instead of 1 Hz 1 flash every second in instances where consumption needs to be further reduced. In systems where loop lengths or current requirements are excessive the ZPW766 may be powered from an external EN544 approved power supply that will automatically be supervised by the ZPW766.Sound OptionsContinuous intermittent and two-tone audible outputs are available from which any combination can be chosen to provide alert and evacuate two stage alarms. All sound types comply with BS5839 Part 1 recommendations. The ZPW766 produces a sound output of up to 97 dBA and may be adjusted in 4 steps down to 88 dBA in instances where lower outputs are required.Key FeaturesCompatible with Ziton addressable fire panelsConnection layout with easy wiring and connection on installationPowered directly from the ZP loop for small installations or externally when many units are requiredFully addressableLED technology for long service life and low current consumption maximising the number of devices on a loopUnique optics for light management with a lens design that optimises light dispersal minimising power wastageUp to 7.5m coverage diameter reducing the number of devices required to cover an areaCoverage switch feature - for smaller areas switch down from 7.5m to 2.5m reducing power consumption and saving up to 50Flash rate switch feature reducing the power consumption by up to 50Soft start up for reduced current peak at start up reducing circuit loadingLocking base to prevent easy removal of device8 Selectable tones with 4 selectable output levelsEN54-3 and EN54-23 approved and CPR certified

GBP 110.29
1

Ziton ZP730-2P Optical Smoke Sensor - Polar White

Ziton ZP730-2P Optical Smoke Sensor - Polar White

Ziton ZP730-2P Optical Smoke Sensor - Polar WhiteDesigned for early response to slow burning smouldering fires the ZP730-2P is a POLAR WHITE addressable smoke detector developed to provide reliable sensing for most fire alarm applications. The detectors proven stability in air movement associated with air conditioning systems has made it a popular selection for modern building interiors.Operating on light scatter principles the ZP730-2 fully meets the sensitivity requirements of EN54-7 and is approved by several international approval bodies.Automatic self testFalse and unwanted alarms are virtually eliminated - smoke levels are continuously sensed by the unit and transmitted via the ZP wiring loop as electronic signals. These are assessed and verified by the control panel prior to any alarm decision being taken.Installed as part of a ZP addressable system up to 127 sensing devices may be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a unique address that is polled by the panel every two seconds.Sensor sensitivity calibration and self-test are carried out automatically by the ZP system. Removal or replacement of an incorrect sensing device will be identified by the system and shown as a fault. Sophisticated auto contamination adjustment compensates for any drift in performance due to dirt in the sensing chamber.Locking base optionFor ease of removal sensors plug into a range of base units by a simple twist and lock action. A site selectable option is provided to lock the sensor into its base. Once applied the unit can only be removed by means of a special tool.A red LED indicator situated on the sensor moulding flashes to indicate when the unit is in alarm. Space for address labels is provided on sensor and base mouldings ensuring units are replaced in their correct location and address numbers can be identified from floor level.Key FeaturesResponds to slow burning firesEN54-7 and CPR certifiedAnalogue sensing - reduces false and unwanted alarmsAddressable - system knows the status and location of every sensorAlarm verification self test auto contamination adjustment

GBP 36.17
1

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar WhiteThe ZR432-2PA is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PA is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSounder with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified

GBP 232.56
1

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red IndicatorThe ZR432-2PAV is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder with visual indicator all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PAV is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders. The red 360 visual indicator non EN5423 complaint allows for a 0.5 Hz flash rate and supports the sounder activation for noisy environments.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSoundervisual indicator combination with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified

GBP 318.46
1