Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

333 results (0,16433 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120mOptical beam smoke detector consists of separate transmitter and receiver heads and a low level controller.The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.The system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a pre-set level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Range 5 to 120m integral laser alignment controller can support 2 pairs of transmitter and receivers additional pairs are available FD310H.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from ControllerSupply voltage 12-36VDCCurrent Controller 14mA per transmitter head 8mAFire and Fault relays per detector head - rated 2A 30VDCDetector head dimensions per transmitter and receiver unit mm 74w x 74h x 161dController dimensions mm 203w x 124h x 73d

GBP 947.02
1

Ziton CP-132EL-I 2 Port RS 422485 PCI Express Connection to ZP3 Network

Ziton Z-PCRS485-2 RS485 Interface Card for PC Connection to ZP3 Network CP-132UL-I-V2

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless Installations

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless Installations

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless InstallationsThe ZR4ST-3 is a portable radio survey kit to assist in the validation of an 868 MHz wireless fire alarm system prior to installation. A site survey is always required prior to installation for all wireless devices to ensure full system operability after installation.Operating PrincipleFire systems are often required in buildings where cable wiring presents a challenge because the fabric of the building or where the interior design would be negatively affected by the use of cables. It could also be difficult to introduce cable runs into old buildings that were not designed with a modern cable infrastructure. It is in these architecturally sensitive buildings that wireless fire detection is ideal.The ZR4ST-3 survey tool helps establish the viability of a wireless installation in such buildings by allowing a pre-installation survey to be conducted within the standard operating parameters of the system. The ZR4ST-3 confirms the signal strength at every desired location and helps with the overall system design by providing clear go no-go location information.The RangeA typical 868 MHz fire system may consist ofWired or wireless interface modulesWireless fire detectorsWireless notification devicesWireless detectornotification device combinationsWireless manual call pointsWireless inputoutput modulesAll of these require validation for signal strength prior to installation.

GBP 647.00
1

Ziton ZP755-COV-P Cover For All ZP755B Base Sounders With No Detector - Polar White

Ziton ZP2 2 Loop Expansion PCB ZP2-LB

Ziton GBX370 Intrinsically Safe Galvanic Isolator

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 Loop

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 Loop

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 LoopThe ZPR868-H is a Ziton protocol radio hub for interfacing up to 4 loops of wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP panel and provides a seamless interface between the panel and the wireless devices.Performance and RangeWith support for smart cluster technology the ZPR868-H provides extended wireless coverage over zone type wireless systems. Diversity antennae allows for extended communication range in all directions whilst multipath communication techniques minimises the risk of interference from external sources.System DesignWith up to 4 hardware loops connected directly from the Ziton fire alarm CIE to the ZPR868-H hub every devices on each of the CIE loops may be connected wirelessly. Cluster communicators ZPR868-C or ZPR868-CM communicate on one side wirelessly to the hub and on the other side to up to 31 wireless devices either detectors notification andor IO units and even other clusters. When redundancy is required multipath communication enables clusters to talk to other clusters to find a reliable communication path back to the hub should its own dual communication frequencies be blocked. Clusters can also communicate with other clusters to extend the wireless communication distance for large installations.Full flexibilityWireless devices are featured in many fire detection and alarm systems and are specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal.Key FeaturesFully loop powered4-Loop connectivity to up to 504 wireless devices2-Way communication with up to 31 wireless clustersDiversity transceivers allow maximum operational rangeVariable power outputUnique multi-path smart cluster technology supportAutomatic selection from 32 radio channels for reliable communication868MHz harmonised frequency supportETSI 300-220 approvedEN54-18 25 complaint and CPR certified

GBP 467.40
1

Ziton DMN800 Call Point Resettable Element

Ziton ZP3AB-RS232 Serial Communications Optional Facility Card

Ziton 71501N 4-loop analogue control panel 230V

Ziton 71501N 4-loop analogue control panel 230V

Ziton 71501N 4-loop analogue control panel 230VRecognise real fires soonerAdvanced panel design combined with high sensitivity smoke and fire sensing enables the ZP3 control panel not only to identify and disregard conditions that would result in false or unwanted alarms but to recognise real fires sooner. The ZP3 is available in 2 and 4 loop configurations accommodating up to 508 sensing addresses. For sites requiring more loops panels may be networked together to form systems capable of controlling more than 30 000 devices from as much as 64 control panels.Unique device addressesUp to 127 line devices detectors call points sounders or interface units may be connected to each of the ZP3 loops. All loop devices incorporate switch settings enabling them to be assigned a unique address the location of which is pinpointed and polled by the panel every two seconds. Variations in the detectors environment caused by increases of temperature or products of combustion are reported to the panel where they are processed and compared to known fire data prior to any alarm output being activated.Software flexibilityConstant communication between control panel and detector enables the ZP3 to provide a wide range of user facilities including pre alarm constant sensitivity adjustment service and near service listings for all detector types. Software flexibility enables facilities such as alarm organisation evacuation procedures and complex cause and effect requirements to be easily programmed into any system. All customer and site data is held in non volatile flash memory ensuring both ease of initial system data input and subsequent on site amendments and modifications should they be required.Optional facilitiesAn onboard printer module together with a series of facility boards can be added to the standard panel to extend any panel up to 768 programmable inputs and outputs.Remote diagnosticsDesigned to provide the user with full facilities for both fault diagnosis and system configuration off site the remote diagnostics hardware and software package makes information available to service personnel prior to visiting site for remedial action or maintenance activity.Key FeaturesCPR Certified to EN542 and 4Advanced sensing techniquesExtensive networking abilityLoop powered sounders supportEase of operationService and near service facilitySophisticated alarm verificationAutomatic self testDay night controlRadio loop interface supportAutomatic contamination adjustment for each detectorIntelligent loop isolationSelf test sounder supportPassword protectionEvent log

GBP 2525.29
1

Ziton 71401N 2 Loop Analogue Control Panel 230V

Ziton 71401N 2 Loop Analogue Control Panel 230V

Ziton 71401N 2 Loop Analogue Control Panel 230VRecognise real fires soonerAdvanced panel design combined with high sensitivity smoke and fire sensing enables the ZP3 control panel not only to identify and disregard conditions that would result in false or unwanted alarms but to recognise real fires sooner. The ZP3 is available in 2 and 4 loop configurations accommodating up to 508 sensing addresses. For sites requiring more loops panels may be networked together to form systems capable of controlling more than 30.000 devices from as much as 64 control panels.Unique device addressesUp to 127 line devices detectors call points sounders or interface units may be connected to each of the ZP3 loops. All loop devices incorporate switch settings enabling them to be assigned a unique address the location of which is pinpointed and polled by the panel every two seconds. Variations in the detectors environment caused by increases of temperature or products of combustion are reported to the panel where they are processed and compared to known fire data prior to any alarm output being activated.Software flexibilityConstant communication between control panel and detector enables the ZP3 to provide a wide range of user facilities including pre alarm constant sensitivity adjustment service and near service listings for all detector types. Software flexibility enables facilities such as alarm organisation evacuation procedures and complex cause and effect requirements to be easily programmed into any system. All customer and site data is held in non-volatile flash memory ensuring both ease of initial system data input and subsequent on site amendments and modifications should they be required.Optional facilitiesAn onboard printer module together with a series of facility boards can be added to the standard panel to extend any panel up to 768 programmable inputs and outputs.Remote diagnosticsDesigned to provide the user with full facilities for both fault diagnosis and system configuration off site the remote diagnostics hardware and software package makes information available to service personnel prior to visiting site for remedial action or maintenance activity.Key FeaturesCPR Certified to EN542 and 4Advanced sensing techniquesExtensive networking abilityLoop powered sounders supportEase of operationService and near service facilitySophisticated alarm verificationAutomatic self-testDay night controlRadio loop interface supportAutomatic contamination adjustment for each detectorIntelligent loop isolationSelf-test sounder supportPassword protectionEvent log

GBP 1597.32
1

Ziton ZP3AB-OP24 24 Way Transistor Output Board

Ziton 80101-ZT Extinguishing Status Unit

Ziton ZP2-AE2 Addressable Fire amp Evacuation Panel 2 Loops

Ziton ZP2-AE2 Addressable Fire amp Evacuation Panel 2 Loops

Ziton ZP2-AE2 Addressable Fire Evacuation Panel 2 LoopsThe Kidde Commercial ZP2-A Fire Alarm System combined withthe Kidde Commercial Zitons range of addressable devices primarily focuses onsmall to medium-sized applications. The ZP2-A Fire Panel is an addressable EN54compliant panel which is expandable up to 4 loops and networkable with up to 64panels. It is available in multiple languages and keypad variants incl. firerouting and fire protection controls to meet the different country localrequirements within Europe.TheZP2-A Panel is intuitive and easy to use with less time required to installconfigure commission and maintain resulting in anoptimum cost of ownership throughout the entire life of the system.The ZP2-A Panel with its onboard connectivity IP SerialUSB options brings integration possibilities with the ATS8600 AdvisorIntegrated Management Software building management systems Central MonitoringStations and Remote Control of the panel helping with remote diagnosticsmaintenance and programming.The panel is easyto use for installation and maintenance withThe availability of High-Power Loops that reduces cablingcostsThe ability to operate fully out of the box without powerfor up to 72 hoursIP connectivity enabling diagnostics to be done remotelyreducing visits to site and saving travelling timeFast to configureprogram functionality for installersusing setup wizards and auto-configurationPre-programmed operatingregional modesIntuitive service modeFull backward compatibilityHybrid wireless version available for areas where cabling isdifficult to runThe facility to integrate with ATS8600 Advisor Management softwareto operate as part of a larger integrated systemA system that can be monitored 247 by a central monitoringstationIn addition the panel is available withSmall and standard size panel cabinets compact repeatersavailable as wellTools and software for loopbattery calculations and panelconfigurationsNetwork functionality to conventional incl. extinguishingpanelsAdditional conventional sounder outputs per loopOptionally up to 40 LED Zone indicators for Fireand Fault

GBP 1179.32
1

Ziton ZP2-AE1 Addressable Fire amp Evacuation Panel 1 Loop

Ziton ZP2-AE1 Addressable Fire amp Evacuation Panel 1 Loop

Ziton ZP2-AE1 Addressable Fire Evacuation Panel 1 LoopThe Kidde Commercial ZP2-A Fire Alarm System combined withthe Kidde Commercial Zitons range of addressable devices primarily focuses onsmall to medium-sized applications. The ZP2-A Fire Panel is an addressable EN54compliant panel which is expandable up to 4 loops and networkable with up to 64panels. It is available in multiple languages and keypad variants incl. firerouting and fire protection controls to meet the different country localrequirements within Europe.The ZP2-A Panel is intuitive and easy to use with less timerequired to install configure commission and maintain resulting in anoptimum cost of ownership throughout the entire life of the system.The ZP2-A Panel with its onboard connectivity IP SerialUSB options brings integration possibilities with the ATS8600 AdvisorIntegrated Management Software building management systems Central MonitoringStations and Remote Control of the panel helping with remote diagnosticsmaintenance and programming.The panel is easyto use for installation and maintenance withThe availability of High-Power Loops that reduces cablingcostsThe ability to operate fully out of the box without powerfor up to 72 hoursIP connectivity enabling diagnostics to be done remotelyreducing visits to site and saving travelling timeFast to configureprogram functionality for installersusing setup wizards and auto-configurationPre-programmed operatingregional modesIntuitive service modeFull backward compatibilityHybrid wireless version available for areas where cabling isdifficult to runThe facility to integrate with ATS8600 Advisor Management softwareto operate as part of a larger integrated systemA system that can be monitored 247 by a central monitoringstationIn addition the panel is available withSmall and standard size panel cabinets compact repeatersavailable as wellTools and software for loopbattery calculations and panelconfigurationsNetwork functionality to conventional incl. extinguishingpanelsAdditional conventional sounder outputs per loopOptionally up to 40 LED Zone indicators for Fireand Fault

GBP 945.48
1

Ziton N-MC-FC Transparent Hinged Cover

Ziton 71601 ZP3 Repeater Panel

Ziton 71601 ZP3 Repeater Panel

Ziton 71601 ZP3 Repeater PanelDesigned to match the ZP3 main control panel the ZP3-RDU remote display is an attractive low profile unit providing repeat indication and system control at a location remote from the main control panel position. Housed in a small slim enclosure the remote unit has a fascia design and layout in matching style to ZP3 control equipment. Up to 32 remote units can be connected to any central panel.The unit features zonal designation for up to 50 zones a 4 row 160 character back lit liquid crystal display and an at a glance system status LED matrix. Controls are provided for accept reset silence and sound alarms. A restore disabled alarms facility re-enables previously disabled alarm sounders immediately should the need for an evacuation arise.The unit is driven from an optional serial driver card added to the main board within the ZP3 panel enclosure. Wiring to the main control panel is by serial link screened twisted pair which can be daisy chained teed off or spurred. The total wiring length of all remote display units connected to a main control panel can be up to two kilometres. The ZP3-RDUB1 can either be powered directly from the main panel 24 VDC or by a remote power supply unit. A version featuring a stainless-steel enclosure is also available.Control keys are provided to select listings of current fires faults and disablements for display. Initial information is displayed by zone with a further facility to display point addresses within the displayed zone. Operating as an indicator panel only in its normal mode the ZP3-RDUB1 system control functions are accessed by means of a security key switch. Internal switches are provided to configure the unit to operate as an indicator only with no control facilities with controls by key access or with control functions enabled on a permanent basis.Key FeaturesRemote control and indicationUp to 32 remote units connected to each main panel4 row 160 character LCDReplicates main panel fasciaRestore disabled sounders facility

GBP 887.51
1

Ziton Stainless Steel Repeater Panel 24V LCD amp controls 130101

Ziton Stainless Steel Repeater Panel 24V LCD amp controls 130101

ZitonStainless Steel Repeater Panel 24V LCD controlsDesigned to match the ZP3 main control panel the ZP3-RDU remote display is an attractive low profile unit providing repeat indication and system control at a location remote from the main control panel position. Housed in a small slim enclosure the remote unit has a fascia design and layout in matching style to ZP3 control equipment. Up to 32 remote units can be connected to any central panel.The unit features zonal designation for up to 50 zones a 4 row 160 character back lit liquid crystal display and an at a glance system status LED matrix. Controls are provided for accept reset silence and sound alarms. A restore disabled alarms facility re-enables previously disabled alarm sounders immediately should the need for an evacuation arise.Displays both zone and address informationControl keys are provided to select listings of current fires faults and disablements for display. Initial information is displayed by zone with a further facility to display point addresses within the displayed zone. Operating as an indicator panel only in its normal mode the ZP3-RDUB1 system control functions are accessed by means of a security key switch. Internal switches are provided to configure the unit to operate as an indicator only with no control facilities with controls by key access or with control functions enabled on a permanent basis.Serial link connectionThe unit is driven from an optional serial driver card added to the main board within the ZP3 panel enclosure. Wiring to the main control panel is by serial link screened twisted pair which can be daisy chained teed off or spurred. The total wiring length of all remote display units connected to a main control panel can be up to two kilometres.The ZP3-RDUB1 can either be powered directly from the main panel 24 VDC or by a remote power supply unit. A version featuring a stainless steel enclosure is also available.Key FeaturesRemote control and indicationUp to 32 remote units connected to each main panel4 row 160 character LCDReplicates main panel fasciaRestore disabled sounders facility

GBP 1276.07
1

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit BoardThe 2010-2-PIB Peripherals Interface Board is an accessory of the small to medium size intelligent addressable life safety control systems. In total there are 4 variants of this board. The 2010-2-PIB is the most extended variant of the range and provides ways to interface other electronic equipment on site.The board can be plugged directly on the front of the main board inside the big size control panel variants on top of the new release 3 chassis. No additional wiring is required. You can use the pluggable connectors to make your connections to the field wiring. Connect an external power supply to the board directly to reduce the load of your system.The 2010-2-PIB Peripherals Interface Board provides eight inputs and outputs and four relay outputs for compatible control panels. The board is designed to support German marketplace requirements in control panels operating in VdS 2540 mode and provides an interface to the IFAM System 3000 network fire brigade equipment and other regional control and indicating equipment and devices. The board can be powered from the control panel or from an external power supply providing 24 VDC to each of the supervised outputs. Inputs and outputs excluding relay outputs are supervised for short circuit and open circuit faults.Key Features8 supervised inputs8 supervised outputs4 relay outputsOption to externally powerInterface to the IFAM System 3000 networkOperating in VdS 2540 modePluggable connectors

GBP 182.74
1

Ziton SC008CO CO Fire Detector Test Spray

Ziton Alarmline V Bracket Stainless Steel with Silicon Sleeve

Ziton 2010-2-PIB-8O Interface Printer Circuit Board with 8 Outputs