Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

5 results (0,13892 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery PackThe ZR451-3 is a wireless 868 MHz single channel inputoutput unit. It provides a method of interfacing a supervised input or potential free output signal into and out of the fire detection and alarm system in areas where the installation of system wiring is not an option.The systemThe ZR451-3 communicates with the main control panel via a hardwired radio loop module that can be installed anywhere on the ZP loop. When the input gets an alarm signal it passes it via the radio loop module to the main fire control panel where it is processed. The output of the interface provides volt free change over contacts for connecting ancillary equipment and is programmed separately activated individually on in a group.High intensity LED indicators positioned on the ZR451-3 may be illuminated by a manually activated push button to identify when the interface has operated providing clear identification of the signal source.Installed as part of a ZP addressable system up to 127 line devices sensors call points or interface units may be connected to each of the control panel loops. Each wireless device is assigned its own IDENT address with which the main control panel communicates with it providing the same system facilities as directly wired devices.UsageAs an input the ZR451-3 may receive signals from other alarm equipment e.g. beam detectors aspiration detectors etc. Used as an output the unit switches equipment controlled by the fire detection system e.g. air conditioning systems magnetic door release units etc. Both input and output facilities are available from the same unit and may be operated simultaneously or individually as programmed at the fire control panel.Power supplyThe ZR451-3 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. The ZR451-3 features battery condition monitoring and reporting.Key FeaturesAddressable inputoutput interface unitWire free activationVolt free relay outputMonitored input for fire and faultTwo way radio communication

GBP 234.91
1

Ziton ZR455-3W 868Mhz White Radio Sounder

Ziton ZR455-3W 868Mhz White Radio Sounder

Ziton ZR455-3W 868Mhz White Radio SounderThe ZR455-3W is a WHITE addressable wireless sounder operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system. ZR455-3 sounders feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA.Highest signal integrityTo ensure the highest signal integrity ZR455-3 sounders transmit and receive statuses and instructions to and from the panel in a multi-path harmonised European 868 MHz band. When installed as part of a ZP addressable fire system where up to 127 device addresses are available per loop up to 62 ZR455-3 devices may be used spread across two radio loop controllers. Every wireless device controlled through the ZPR868 loop interface is assigned its own address with which the main control panel communicates providing the same system facilities as directly wired devices.System designZR455-3 sounders provide notification where the installation of hard wired sounders is not an option. They form part of an extensive range of wireless fire alarm devices that includes audio-visual notification smokeheat detectors manual call points and inputoutput devices.Suitable for applications specifying BS58391 ZR455-3 sounders may be addressed as a standalone units or as part of a group where several units in the same location are synchronized to operate simultaneously. Designed for surface mounting in indoor applications they have no external aerials and are supplied complete with matching back box. The ZR455-3 is rated at IP54 and constructed of ABS plastic.Power supplyPower for the ZR455-3 sounders is derived from two independent and supervised battery sources using standard alkaline batteries allowing up to 5 years of operational life.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tones

GBP 215.44
1

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery Pack

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery Pack

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery PackThe ZR455-3R is a RED addressable wireless sounder operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system. ZR455-3 sounders feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA.Highest signal integrityTo ensure the highest signal integrity ZR455-3 sounders transmit and receive statuses and instructions to and from the panel in a multi-path harmonised European 868 MHz band. When installed as part of a ZP addressable fire system where up to 127 device addresses are available per loop up to 62 ZR455-3 devices may be used spread across two radio loop controllers. Every wireless device controlled through the ZPR868 loop interface is assigned its own address with which the main control panel communicates providing the same system facilities as directly wired devices.System designZR455-3 sounders provide notification where the installation of hard wired sounders is not an option. They form part of an extensive range of wireless fire alarm devices that includes audio-visual notification smokeheat detectors manual call points and inputoutput devices.Suitable for applications specifying BS58391 ZR455-3 sounders may be addressed as a standalone units or as part of a group where several units in the same location are synchronized to operate simultaneously. Designed for surface mounting in indoor applications they have no external aerials and are supplied complete with matching back box. The ZR455-3 is rated at IP54 and constructed of ABS plastic.Power supplyPower for the ZR455-3 sounders is derived from two independent and supervised battery sources using standard alkaline batteries allowing up to 5 years of operational life.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tonesAcoustic self testDual battery supply5 year battery life at normal conditionsHarmonised European 868 MHz frequency bandCPD certified

GBP 215.44
1

Ziton GBX2000 I.S. Galvanic Isolation Barrier For Conventional Systems

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop ModuleThe ZP3AB-NLM network loop module enables individual ZP3 control panels to be connected in a peer to peer secure loop network. If there is an open or short circuit present on the network wiring the NLMs determine where the fault lies isolate the faulty section of wiring and maintain full loop integrity.Total cable length throughout the network can be up to a maximum of two kilometres and may be extended by setting designated NLM modules as booster units contact Ziton technical support department for full details. Communication between loop modules operates by RS485 protocol over screened twisted pair wiring.Unique address on the network loopZP3AB-NLM3 modules connect to ZP3 control panels via a ZP3AB-NET1 card and are designed to fit onto an auxiliary chassis inside each control panel or auxiliary equipment cabinet. Each ZP3 control panel is connected to the loop network through an ZP3AB-NLM3 module. All modules incorporate switch settings enabling them to be assigned a unique loop address. An output fault signal is provided by a volt free changeover relay with contacts rated at 1A at 230VDC30VAC.Diagnostic and system indicationIn each network loop one module must be set to address 1 and designated as the master. This device manages the healing sequence and monitors loop integrity. All other modules are connected to the network loop in slave mode.In slave mode modules can operate in multiple modesBoost - serving as an interconnection between panels at distances over 1000 metresHealing establishing the condition of the loop and isolating sections if necessaryRecovered normal condition after a section isolationDiagnostic system interrogation to establish the location of a break in the loop wiringIn addition to indications of data being transmitted and received from each port LED indicators are also provided for System OK Loop Fault Loop Open and Data Error.Key FeaturesProvides a secure loop networkEnhanced LED diagnosticsBoost mode for long cable runsPropagation time periods for third party equipment operationCommunications screen isolation between input and output channels

GBP 277.06
1