Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

95 results (0,15872 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone InterfaceThe A70E-2 zone interface is fully loop powered and enables existing or new conventional zones to be interfaced to an analogue system allowing all areas of a site to be controlled by the ZP analogue panel. Through its interface each zone is assigned a unique address. Zones are monitored for fire and fault conditions and status is reported to the ZP control panel every 2 seconds. Zones of up to 15 Ziton Z600 conventional trigger devices can be connected to the interface with a maximum of 127 interface units installed on each ZP loop.The A70E monitors its conventional zone wiring for open and short circuit faults via end of line resistors supplied with the unit. When detectors are installed with Z6-BS5 bases the interface maintains complete operation of all other zone devices should a detector from within the zone be emoved from its base. Clear visual indication is shown on the front of the A70E moulding for alarm red LED and fault amber LED.Deriving power directly from the loop wiring and with a low current consumption in addition to zonal connection the interface has many system applications ranging from the interface of equipment for hazardous areas to the operation of magnetic door retainers via an interposing relay and linear beam detectors. Housed in low profile mouldings the interface is designed to clip directly onto a standard DIN35 rail fixing or be installed in a SMB-DIN100 box one unit capacity or a SMB-DIN200 box two unit capacity. In systems where numerous interfaces are installed or current requirement is excessive the A70E can be powered from an external power supply.Key FeaturesInterfaces up to 15 Ziton Z600 conventional devices to the ZP loopAddressable - reports status every 2 secondsMonitors conventional zone wiringDetector removal monitoring with Z6-BS5 basesDIN35 rail mountedUp to 127 conventional zones interfaced to each ZP loop with external PSU

GBP 114.34
1

Ziton DI-9319E Intelligent Addressable Zone Monitor Unit - Needs 24VDC

Ziton ZP1-F4-MB ZP1 Main Board - 4 Zone Replacement Main PCB for the ZP1-F4-xx

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3-03ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan. With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-X3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.The ZP1-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organisation and planning.Key FeaturesModern elegant designEasy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zones Single zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-B Sounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary suppliesAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk testRedundant networking to ZP1 conventional and ZP2 addressable nodesIntrinsically safe and EN54-13 zone support

GBP 376.19
1

Ziton ZP1-F2-03 Conventional 2 Zone Fire Panel with User Interface

Ziton ZP1-F2-03 Conventional 2 Zone Fire Panel with User Interface

Ziton ZP1-F2-03 Conventional 2 Zone Fire Panel with User InterfaceThe ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 194.68
1

Ziton ZP1-F8-03 Conventional 8 Zone Fire Panel with User Interface

Ziton ZP1-F8-03 Conventional 8 Zone Fire Panel with User Interface

Ziton ZP1-F8-03 Conventional 8 Zone Fire Panel with User InterfaceZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F8 is a conventional fire alarm control panel. It is supplied in local language with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 237.49
1

Ziton ZP1-F4-03 Conventional 4 Zone Fire Panel with User Interface

Ziton ZP1-F4-03 Conventional 4 Zone Fire Panel with User Interface

Ziton ZP1-F4-03 Conventional 4 Zone Fire Panel with User InterfaceZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F4 is a conventional fire alarm control panel. It is supplied in local language with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 217.58
1

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xxThe ZP1-F2-MB is a ZP1 Main Board - 2 Zone Replcement Main PCB designed for theZP1-F2 range.ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsRoHS compliantWEEE compliantNEN2535 NBNS21-100 and BS5839-1 compliantCPD certifiedEN542 EN544 and CE approvedType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 180.13
1

Ziton ZP1-F8-99 Conventional Fire Alarm Panel - 8 Zone

Ziton ZP1-F8-99 Conventional Fire Alarm Panel - 8 Zone

Ziton ZP1-F8-99 Conventional Fire Alarm Panel - 8 ZoneZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to midsized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F8 is a conventional fire alarm control panel. It is supplied in local language with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset extended fire routing delay fire routing inhibit delay facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 299.23
1

Ziton ZP1-F8 Conventional Fire Panel With User Interface 8 Zone

Ziton ZP1-F8 Conventional Fire Panel With User Interface 8 Zone

Ziton ZP1-F8 Conventional Fire Panel With User Interface 8 ZoneZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to midsized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F8 is a conventional fire alarm control panel. It is supplied in local language with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset extended fire routing delay fire routing inhibit delay facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 252.84
1

Ziton ZP1-F4 Conventional Fire Panel With User Interface 4 Zone

Ziton ZP1-F4 Conventional Fire Panel With User Interface 4 Zone

Ziton ZP1-F4 Conventional Fire Panel With User Interface 4 ZoneZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to midsized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F4 is a conventional fire alarm control panel. It is supplied in local language with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset extended fire routing delay fire routing inhibit delay facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 235.15
1

Ziton ZP1-F2 Conventional Fire Panel With User Interface 2 Zone

Ziton ZP1-F2 Conventional Fire Panel With User Interface 2 Zone

Ziton ZP1-F2 Conventional Fire Panel With User Interface 2 ZoneZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to midsized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset extended fire routing delay fire routing inhibit delay facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 176.24
1

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit with Battery PackThe ZCR452 is an interface between a conventional fire detection zone and a range of wireless 868 MHz field devices. It provides a method of interfacing a conventional system with a zone of wireless field devices in areas where the installation of system wiring is not an option.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 allows for any compatible conventional fire detection zone to be connected directly to the unit. The ZCR452 in turn provides fire and fault notifications from the wireless field devices to these conventional circuits. In addition any conventional notification circuit may also be wired to the ZCR452 allowing wireless notification devices to be controlled from the conventional notification controller in a similar way to any hardwired conventional notification device.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. Any abnormal battery condition is reported to the fire system.Key FeaturesProvides conventional systems with wireless capabilitiesNo special conventional interfaces requiredFlexible impedance matching for conventional circuitsMonitors all wireless alarm and fault messagesConventional control interface for wireless notification devices and IOTwo way radio communicationFully EN54 compliant and CPR certified

GBP 194.32
1