Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

16 results (0,13205 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo 45682-860APO Black XPERT Universal Address Card Pack of 10

Apollo Series 65 Marine Mounting Base 45681-200MAR

Apollo Series 65 Standard Base - 45681-200APO

Aritech Hinged Cover DMN782 PS200

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201The Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the L1 IN and L1 OUT wiring terminals.This base can only be used with compatible control equipment.OperationAll detectors in the Series 65 range fit into Series 60 standard mounting bases. The bases are of 100mm diameter and have five terminals marked according to their function Line 1 in line 1 out line 2 in and out remote indicator negative earth. Detectors are polarity insensitive so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors.The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 51 to 69mm. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connectorContinues to work during unauthorised removal of detectorsBrand FeaturesWide-operating voltage of 933 V DCWide-operating and storage temperature of -20C to 60CCan be used on security systemsElectrically and mechanically compatible with Series 60Proven detection performance

GBP 2.60
1

Ziton DMN800 Call Point Resettable Element

Push Bar To Open - Rigid 600mm x 100mm PBTOR

Push Bar To Open - Vinyl 600mm x 100mm PBTOV

Fireclass 4B-D Conventional Diode Base

Apollo Soteria XPERT 8 Intelligent Mounting Base SA5000-200APO

Apollo Soteria XPERT 8 Intelligent Mounting Base SA5000-200APO

Apollo Soteria XPERT 8 Intelligent Mounting Base SA5000-200APOAll detectors in the Soteria XP95 and Discovery range fit into the XPERT 8 Intelligent Mounting Base.The base has a wide interior diameter for ease of access to cables and terminals. The E-Z Fit feature allows you to fit the base screws place the XPERT 8 Intelligent Mounting Base over the screws slide it into place and tighten the screws.The detector requires a clockwise rotation into the base for fitting. Additionally the detector can be locked into the base for increased security by a grub-screw using a 1.5mm hexagonal driver.The XPERT 8 card part number 38532-064 supplied with the base has pre-punched pips to remove to set the address. Refer to the Coding Guide for details on how to set the address.Backwards CompatibilitySoteria detectors have been designed to operate on XP95 and Discovery loops. This allows for Soteria detectors and bases to operate on existing systems and for Soteria detectors to operate on XP95 and Discovery bases XPERT 7 Intelligent Mounting Base. It should be noted that not all features of Soteria will be available when used with XP95 or Discovery fire control panels. If Soteria detectors are used with XP95 fire control panels incorporating drift compensation algorithms these must be disabled when communicating with Soteria devices.When Soteria detectors are used with an XPERT 7 Intelligent Mounting Base on a CoreProtocol system Soteria devices will have a 128 address offset due to only 7 address pips being available on the XPERT 7 card. For example an XPERT 7 card set at 32 will address as 160 on CoreProtocol with Soteria detectors.Key FeaturesCompatibility with Soteria XP95 and Discovery detectorsIsolated and Non-isolated devices supportedIsolated wiper - maintains loop connectivity during temporary removal of devicesXPERT 8 card for Core-ProtocolE-Z Fit allows for simple mounting of the detector base after wiringKeyed to accept only addressable devicesBase mark allows for LED detector alignmentPlease Note XPERT 8 card increase the address capacity to 254 when using Soteria detector and Core-Protocol enabled fire control panel.

GBP 2.64
1

C-Tec C4408D ActiV Diode Base

C-Tec C4408 ActiV Standard Non-Diode Base

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Mounting Base - 45681-210APOAll detectors in the Discovery range fit the IntelligentMounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.Universal address cards known as XPERT cards are supplied with all bases. Consult the coding guide in the installation instructions to determine which pips are to be removed from the card to give the correct address.Lay the card on a flat surface pips down insert a screwdriver into the slot on the reverse of the pip to be removed and give a firm twist. When the card is coded insert it into the slot in the side of the appropriate base making sure that the card locks itself into place. As a detector is inserted into the base the remaining pips operate the address buttons on the detector and the detector electronics reads the address.OperatingAn earth connection is not required for either safety or correct operation of detectors. The ground earth terminal is isolated and is provided for tidy termination of grounded conductors or cable screens and to maintain earth continuity where necessary. All terminals are marked according to their function.Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws. The slots enable two fixing screws to be located at a spacing of 51mm to 69mm. Detectors fit into bases one way only without snagging and require clockwise rotation without push force to be plugged in.Key Features XPERT AddressingOne way fit of detectorLocking feature to prevent unauthorised detector removal

GBP 2.50
1