Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

232 results (0,14778 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

EMS Firecell FC-868-SE2 Wireless Survey Kit

Gent 585050 Power Supply 1U - 24VDC 190A

Gent 585051 Power Supply 2U - 24VDC 380A

Pepperl Fuchs KFD0-CS-EX1.54-Y2 Repeater

Pepperl amp Fuchs KFD0-CS-EX2.54 Repeater

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test KitSigNET recommends all its induction loop systems are tested using a Fosmeter Pro Induction Loop Test Kit FPROK1. Designed to simplify the setup of an induction loop system to the latest version of BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes the kit includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated signal generator cw pre-loaded test tones and a set of headphones.As well as checking the magnetic field strength of an induction loop system it also measures background noise frequency response metal compensation AND allows you to listen to the loop signal. The tester and signal generator are each powered by a 9V PP3 battery and both are supplied in protective canvas carrying cases.Key FeaturesA must-have accessory for all AFILSinstallers and service engineers.Simplifies the setup of an induction loop system to BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes.Includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated FPROSG Signal Generator cw pre-loaded test tones voice and music samples and a set of HEAD1 headphones.Checks the magnetic field strength of an induction loop system and measures background noise frequency responseandmetal compensation.Loop listening circuitry allows subjective listening tests to be carried out using the headphones supplied.Powered from a 9V PP3 battery.Supplied in a protective canvas carrying case.Auto power-off function helps to preserve battery life.

GBP 551.70
1

Kentec RIM100M-3-K InputOutput Module For RIM100-E Ethernet LinkTwo Inputs To Monitor

Klaxon Syrex Exd Bell ATEX 230v AC - TCA-0002 17-970232

Klaxon Syrex Exd Bell ATEX 24v DC - TCA-0004 17-970234

Klaxon Syrex EXD Explosion Proof Bell - TCA-0003 17-970233

Talentum 16521-00 UV IR2 Flame Detector Flameproof Exd

Talentum 16521-00 UV IR2 Flame Detector Flameproof Exd

Talentum 16521-00 UV IR2 Flame Detector Flameproof ExdThe Talentum flameproof Ultra-Violet dual Infra-Red UVIR Flame Detector is designed to protect hazardous areas where open fires may be expected and detects almost all flames including hydrocarbon fires with 4.3 m emissions through to invisible fires such as hydrogen. The UVIR Flame Detector is sensitive to flickering low frequency 1-15Hz infra-red radiation emitted by flames during combustion. This detector has a UV sensor and two IR sensors which respond to different wavelengths of both the ultra-violet and the infra-red spectrum.The signals from these sensors are processed by the detector and checked for characteristics of a flame. The simultaneous detection of both the UV and the IR light by the sensors will signal an alarm. False alarms from flickering sunlight arc welding and lightning are eliminated by a combination of UV and dual IR signal processing techniques. The Talentum UVIR detector has selectable output options of relay contacts or 4-20mA signal as standard.Key FeaturesHighest immunity to false sourcesSolar blindTolerant of fumes vapours dust and mistSuitable for indoor and outdoor areasUnaffected by convection currents draughts or windProven response to multiple fuel typesMulti-spectrum detectionSelectable output optionsSelectable response speedSelectable sensitivity levelsBuilt in auto and manual testLow current consumptionFast response to fireApplicationsChemical PlantsNuclear Power SitesEngine RoomsSpray BoothsPharmaceutical ProductionMilitary ApplicationsMarine IndustryPrinting RefineriesFuel loading racksStorage tanksAircraft hangersPetrochemical onshoreoffshoreBiomass storage and handlingLNGLPG productionApprovalsATEXII 2GD Ex d IIC T6Zones 1 21 2 and 22Worldwide approvals include EN5410 with VdS and LPCB

GBP 3610.50
1

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector 100m

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector 100m

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector 100mThe FD2705R and FD2710R provides an integral loop powered analogue addressable reflective beam detector up to 100m distance. Wiring is restricted to a minimum as the transmitter and receiver are in the same housing. The detector is very easily aligned by means of checking the alignment LEDs. Easy alignment ensures optimum operation both electrically and mechanically. The unit is easily tested using the graduated obscuration test card supplied.The low power consumption of the units allows multiple beams to be powered on the same loop without compromising the systems autonomy. The FD2705R and FD2710R consist of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be use where point smoke detectors are not practical due to height or inaccessibility.The FD27xxR series units are loop powered for connection to 12002000 series fire panels. They use the Aritech 2000 series protocol. Various alarm thresholds may be selected from to suit the environment. If the signal reduces to below the selected threshold and is present for 10 seconds a fire condition is signalled. If the infrared beam is obscured rapidly to a level of 90 or greater for 10 seconds a fault condition is signalled. The detector monitors long term degradation of signal strength caused by component ageing or build-up of dirt on optical surfaces.Key FeaturesLoop Powered2000 series protocolArea coverage up to 600 mRange from 5 - 50 m and 50 - 100 mUp to ceiling heights of 25 mLow current consumption3 selectable alarm thresholdsSelf-check and automatic contamination compensationAutomatic discrimination between fire and faultVertical or horizontal mountEasy wiring and unique alignmentMicroprocessor controlledConforms to BS5839 part 5 and EN54

GBP 742.38
1

Aritech FD2705R 2000 Series Addressable Reflective Beam Detector 50m

Aritech FD2705R 2000 Series Addressable Reflective Beam Detector 50m

Aritech FD2705R 2000 Series Addressable Reflective Beam Detector 50mThe FD2705R and FD2710R provides an integral loop powered analogue addressable reflective beam detector up to 100m distance. Wiring is restricted to a minimum as the transmitter and receiver are in the same housing. The detector is very easily aligned by means of checking the alignment LEDs. Easy alignment ensures optimum operation both electrically and mechanically. The unit is easily tested using the graduated obscuration test card supplied.The low power consumption of the units allows multiple beams to be powered on the same loop without compromising the systems autonomy. The FD2705R and FD2710R consist of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be use where point smoke detectors are not practical due to height or inaccessibility.The FD27xxR series units are loop powered for connection to 12002000 series fire panels. They use the Aritech 2000 series protocol. Various alarm thresholds may be selected from to suit the environment. If the signal reduces to below the selected threshold and is present for 10 seconds a fire condition is signalled. If the infrared beam is obscured rapidly to a level of 90 or greater for 10 seconds a fault condition is signalled. The detector monitors long term degradation of signal strength caused by component ageing or build-up of dirt on optical surfaces.Key FeaturesLoop Powered2000 series protocolArea coverage up to 600 mRange from 5 - 50 m and 50 - 100 mUp to ceiling heights of 25 mLow current consumption3 selectable alarm thresholdsSelf-check and automatic contamination compensationAutomatic discrimination between fire and faultVertical or horizontal mountEasy wiring and unique alignmentMicroprocessor controlledConforms to BS5839 part 5 and EN54

GBP 581.88
1

Klaxon SWG-0005 GP12 Siren 400v 50hz 50 Degree C With Heaters

Klaxon SWG-0032 GP6 Motor Siren - 400VAC - 50Hz

Klaxon SWG-0037 GP10 Siren 400v Ac 50hz 60 Degree C With Heaters

Klaxon SWG-0006 GP12 Motor Siren - 400VAC - 50Hz

Klaxon SWG-0036 GP6 Siren 400v AC 60hz ATEX

Klaxon SWG-0023 GP10 Motor Siren - 400VAC - 50Hz

Kidde Airsense EST-VES-2001-LN Integrated Mini PAVA Unit 2xAB 4 Lines