Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

18 results (0,13384 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier UT232R-200 USB to RS232 UploadDownload Lead - Windows 10

Zeta ZWD Battery Operated Water Detector Alarm

Cooper Fulleon 521301FULL-1301 Motorised Bell 6 Inch 12 Vdc Centrifugal Red

Zeta ZWD-12 Battery Operated Water Detector Alarm with Relay 12V DC

Cooper Fulleon 521601FULL-1601 Motorised Bell 6 Inch 24 Vdc Centrifugal Red

Fireclass 2501012FC Conventional Indoor Call Point

Ziton DC-9204E Innovation Conventional Indoor MCP - Resettable cw Surface Mount Back Box

Fireclass 2501013FC Conventional Manual Call Point with Glass Element with Back Box

Zeta ZT-TH5 Zeta 9V Standalone Heat Detector 1 Year Life

Zeta ZT-ST5-5 3V Standalone Smoke Detector 5 Year Life

Aritech SB01 Swivel Bracket For WallCeiling Mount Designed For Use With AP750 AP475 AP950AM

Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APO

Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APO

Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light.The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode.If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate.To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation.The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 16.52
1

Nittan EVC-H-A2S Standard Heat Detector 54-70 Degrees

STI KIT-GLR-K10 Global Reset Key - 10 Pack

Nittan EVC-P Photoelectrical Optical Smoke Detector

Nittan EVC-P Photoelectrical Optical Smoke Detector

Nittan EVC-P Photoelectrical Optical Smoke Detector with 375 Ohm ResistorUsing a simple but effective technique the EVC-P Optical Detector incorporates a chamber housing an Infra-Red IR LED light and a photodiode light detector set at an obtuse angle preventing it from seeing the light. When smoke enters the chamber the light bounces off the smoke particles and strikes the photodiode causing it to generate an alarm condition when a set threshold value is met.The EVC-P Optical Detector is therefore more sensitive to larger smoke particles which tend to be caused by smouldering fires rather than fast flaming fires.OperationThe smoke chamber of the EVC-P is constructed so that light cannot enter from outside but smoke can pass through the chamber slots. The EVC-P utilises the light scatter sensing principle. The LED pulses every 8 seconds to maintain a low monitoring current. A quick charge time 20 seconds is also achieved. The detector incorporates an alarm verification function which requires two successive pulses before an alarm is given.The interval between the first and second pulse is automatically reduced to four seconds after the first alarm level is monitored. The detector design provides strong immunity to air velocities contamination and RF interference. The geometry of the smoke chamber and optics support assembly is designed to give the best possible signal to noise ratio resulting in excellent response characteristics.Key FeaturesOmniview 360 LEDInternal Alarm Current Limiting ResistorWide Operational Voltage Range 12v-32vOptical Detector

GBP 15.60
1

Conventional Optical Smoke Detector - 2020P

Conventional Optical Smoke Detector - 2020P

Conventional Optical Smoke Detector - 2020PThe 2020P Optical Smoke Detector is part of the Vision range of detectors. Vision is a range of conventional detectors which have been produced using the latest in manufacturing technology and supplied with an array of installer-friendly advanced features making them ideal for all your conventional fire detection requirements.The 2020P Optical Smoke Detector uses a state of the art optical chamber combined with an application specific integrated circuit ASIC to provide quick and accurate detection of fires. A combination of the unique chamber design and other technically advanced features will significantly extend the service intervals before cleaning of the detector becomes necessary.A hand held laser tool can also be used in conjunction with the Vision range of detectors for triggering the Vision detector. With a range of several metres the hand held unit provides an effortless way of remotely triggering the Vision detector. The 2020P Detector has an integral LED which illuminates to provide a local alarm signal.This latches on and remains illuminated until the detector is reset by a momentary power interruption. An optional remote LED annunciator may be used to repeat any alarm signal. A variety of detector bases can be used with the 2020P Detector providing application flexibility and compatibility with a wide range of conventional fire alarm panels. Please note the laser triggering tool does not negate the requirement to test the detector as specified in BS 5839 Pt 12013.Key FeaturesLow profile designLow current drawAutomatic drift compensationRemote alarm trigger featureEasy maintenanceRange of detector bases availableRemote LED OptionApproved to EN5472000 Amendment 1Extended warranty

GBP 16.93
1